Vibrotactile feedback may be able to compensate for the loss of sensory input in lower-limb prosthesis users to improve the mobility function. Designing an effective vibrotactile feedback system requires that users are able to perceive and respond to vibrotactile stimuli correctly and in a timely manner. Our study explored four key tactor configuration variables (i.e., tactors’ prosthetic layer, vibration intensity, prosthetic pressure, and spacing between adjacent tactors) through two experiments. The vibration propagation experiment investigated the effects of tactor configurations on vibration amplitude at the prosthesis–limb interface. Results revealed a positive relationship between vibration amplitude and intensity and a weak relationship between vibration amplitude and prosthetic pressure. Highest vibration amplitudes were observed when the tactor was located on the inner socket layer. The second experiment involving a sample of ten able-bodied and three amputee subjects investigated the effects of tactor configurations on user perception measured by response time, accuracy identifying tactors’ stimulation patterns, and spatial error in locating the tactors. Results showed that placing the tactors on the inner socket layer, greater spacing between adjacent tactors, and higher vibration intensity resulted in better user perception. The above findings can be directly applied to the design of vibrotactile feedback systems to increase the user response accuracy and decrease the response time required for dynamic tasks such as gait. They can also help to inform future clinical trials informing the optimization of tactor configuration variables.
Skip Nav Destination
Holland Bloorview Kids Rehabilitation Hospital,
Toronto, ON M4G 1R8,
e-mail: jandrysek@hollandbloorview.ca
Article navigation
October 2019
Research-Article
Exploring the Tactor Configurations of Vibrotactile Feedback Systems for Use in Lower-Limb Prostheses1
Sam Shi,
Sam Shi
Institute of Biomaterials and Biomedical Engineering,
Toronto, ON M5S 3G9,
e-mail: shuai.shi@mail.utoronto.ca
University of Toronto
,Toronto, ON M5S 3G9,
Canada
e-mail: shuai.shi@mail.utoronto.ca
Search for other works by this author on:
Matthew J. Leineweber,
Matthew J. Leineweber
Department of Biomedical Engineering,
San Jose, CA 95192
e-mail: matthew.leineweber@sjsu.edu
San Jose State University
,San Jose, CA 95192
e-mail: matthew.leineweber@sjsu.edu
Search for other works by this author on:
Jan Andrysek
Holland Bloorview Kids Rehabilitation Hospital,
Toronto, ON M4G 1R8,
e-mail: jandrysek@hollandbloorview.ca
Jan Andrysek
Bloorview Research Institute
,Holland Bloorview Kids Rehabilitation Hospital,
Toronto, ON M4G 1R8,
Canada
e-mail: jandrysek@hollandbloorview.ca
Search for other works by this author on:
Sam Shi
Institute of Biomaterials and Biomedical Engineering,
Toronto, ON M5S 3G9,
e-mail: shuai.shi@mail.utoronto.ca
University of Toronto
,Toronto, ON M5S 3G9,
Canada
e-mail: shuai.shi@mail.utoronto.ca
Matthew J. Leineweber
Department of Biomedical Engineering,
San Jose, CA 95192
e-mail: matthew.leineweber@sjsu.edu
San Jose State University
,San Jose, CA 95192
e-mail: matthew.leineweber@sjsu.edu
Jan Andrysek
Bloorview Research Institute
,Holland Bloorview Kids Rehabilitation Hospital,
Toronto, ON M4G 1R8,
Canada
e-mail: jandrysek@hollandbloorview.ca
Contributed by the Technical Committee on Vibration and Sound of ASME for publication in the Journal of Vibration and Acoustics. Manuscript received June 1, 2018; final manuscript received April 17, 2019; published online June 5, 2019. Assoc. Editor: Miao Yu.
J. Vib. Acoust. Oct 2019, 141(5): 051009 (10 pages)
Published Online: June 5, 2019
Article history
Received:
June 1, 2018
Revision Received:
April 17, 2019
Accepted:
April 18, 2019
Citation
Shi, S., Leineweber, M. J., and Andrysek, J. (June 5, 2019). "Exploring the Tactor Configurations of Vibrotactile Feedback Systems for Use in Lower-Limb Prostheses." ASME. J. Vib. Acoust. October 2019; 141(5): 051009. https://doi.org/10.1115/1.4043610
Download citation file:
Get Email Alerts
Cited By
Numerical Analysis of the Tread Grooves’ Acoustic Resonances for the Investigation of Tire Noise
J. Vib. Acoust (August 2024)
On Dynamic Analysis and Prevention of Transmission Squawk in Wet Clutches
J. Vib. Acoust (June 2024)
Related Articles
Determination of Optimal Counter-Mass Location in Active Prostheses for Transfemoral Amputees to Replicate Sound Limb Swing
J. Med. Devices (December,2014)
Evaluating the Bending Response of Two Osseointegrated Transfemoral Implant Systems Using 3D Digital Image Correlation
J Biomech Eng (May,2011)
Physically Realizable Three-Dimensional Bone Prosthesis Design With Interpolated Microstructures
J Biomech Eng (March,2017)
Related Proceedings Papers
Related Chapters
The Human Factor in Network System Survivability (PSAM-0090)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
A PSA Update to Reflect Procedural Changes (PSAM-0217)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
Strategic Academic Mangment System
International Conference on Software Technology and Engineering, 3rd (ICSTE 2011)