Abstract

Active vibration isolation from an arbitrarily, structurally complex receiver is considered with respect to the impacts of structure flexibility on the open- and closed-loop system characteristics. Specifically, the generally weak influence of flexibility on the open-loop transfer function in the case of total force feedback, in contrast to acceleration feedback, is investigated. The open-loop system characteristics are analyzed based on open-loop transfer function expressions obtained using modal expansion and on modal model order reduction techniques. To closely demonstrate and illustrate the impacts of flexibility on the closed-loop system performance and stability, a problem of automotive engine vibration isolation from a flexible subframe is presented where the neglected dynamics are represented as an output multiplicative model perturbation. A physical explanation as to why the contribution of flexibility to the open-loop transfer function could be neglected in the case of total force feedback in contrast to acceleration feedback is given. Factors for an individual eigenmode to not significantly contribute to the total force output are presented where the deviation of the mode direction relative to the actuator force direction is pointed out as a key one in addition to modal mass and damping coefficient. In this context, the inherent differences between model order reduction by modal and by balanced truncation are being stressed. For the specific automotive vibration isolation application considered, the degradation of robust performance and stability is shown to be insignificant when obtaining a low-order controller by using total force feedback and neglecting flexibility in the design phase.

1.
Fuller
,
C. R.
,
Elliott
,
S. J.
, and
Nelson
,
P. A.
, 1997,
Active Control of Vibration
,
Academic
, New York.
2.
Spanos
,
J.
,
Rahman
,
Z.
, and
von Flotow
,
A.
, 1993, “
Active Vibration Isolation on an Experimental Flexible Structure
,”
Proc. SPIE
0277-786X,
1917
, pp.
674
680
.
3.
Watters
,
B. G.
,
Coleman
,
R. B.
,
Duckworth
,
G. L.
, and
Bukman
,
E. F.
, 1988, “
A Perspective on an Active Machinery Isolation
,”
Proceedings of the 27th Conference on Decision and Control
, Austin, TX, December 7–9, pp.
2033
2038.
4.
Kaplow
,
C. E.
, 1980, “
Active Local Vibration Isolation Applied to a Flexible Space Telescope
,”
J. Guid. Control
0162-3192,
3
(
3
), pp.
227
233
.
5.
Blackwood
,
G. H.
, 1993. “
Active Vibration Isolation for Controlled Flexible Strcutures
,” Ph.D. thesis, Massachusetts Institute of Technology, Cambridge, MA.
6.
Blackwood
,
G. H.
, and
von Flotow
,
A. H.
, 1992, “
Active Control for Vibration Isolation Despite Resonant Base Dynamics
,” Winter Annual Meeting of the ASME, Anaheim, CA, November 8,
DSC-Vol. 38. Active Control of Noise and Vibration
, ASME, New York, pp.
285
294
.
7.
Preumont
,
A.
,
François
,
F.
,
Bossens
,
F.
, and
Abu-Hanieh
,
A.
, 2002, “
Force Feedback Versus Acceleration Feedback in Active Vibration Isolation
,”
J. Sound Vib.
0022-460X,
257
(
4
), pp.
605
613.
8.
Kwakernaak
,
H.
, 1993, “
Robust Control and H∞-Optimization-Tutorial Paper
,”
Automatica
0005-1098,
29
(
2
), pp.
225
273.
9.
MSC. ADAMS, A registered trademark of MSC.Software Corporation., 2 MacArthur Place, Santa Ana, CA 92707.
10.
Gérardin
,
M.
, and
Rixen
,
D.
, 1998,
Mechanical Vibrations, Theory and Application to Structural Dyamics
, 2nd ed.,
Wiley
, New York.
11.
Olsson
,
C.
, 2002, “
Active Engine Vibration Isolation using Feedback Control
,” Tekn. Lic. thesis ISBN= 91-7373-398-9, Linköping University, Linköping, Sweden.
12.
Sefton
,
J.
, and
Glover
,
K.
, 1990, “
Pole/Zero Cancellation in the General H∞ Problem With a reference to a Two Block Design
,”
Syst. Control Lett.
0167-6911,
14
pp.
295
306.
13.
Gawronski
,
W. K.
, 1998,
Dynamics and Control of Structures — A Modal Approach
,
Springer
, New York.
14.
Zhou
,
K.
,
Doyle
,
J. C.
, and
Glover
,
K.
, 1996,
Robust and Optical Control
,
Prentice-Hall
, Upper Saddle River, NJ.
15.
Sohoni
,
V. N.
, and
Whitesell
,
J.
, 1986, “
Automatic Linearisation of Constrained Dynamical Model
,”
Trans. ASME
0097-6822,
108
, pp.
300
304
.
You do not currently have access to this content.