In this paper we study the dynamic behavior of a shallow arch under a point load Q traveling at a constant speed. Emphasis is placed on finding whether snap-through buckling will occur. In the quasi-static case when the moving speed is almost zero, there exists a critical load in the sense that no static snap-through will occur as long as Q is smaller than In the dynamic case when the point load travels with a nonzero speed, the critical load is, in general, smaller than the static one. When Q is greater than there exists a finite speed zone within which the arch runs the risk of dynamic snap-through either while the point load is still on the arch or after the point load leaves the arch. The boundary of this dangerous speed zone can be determined by a more conservative criterion, which employs the concept of total energy and critical energy barrier, to guarantee the safe passage of the point load. This criterion requires the numerical integration of the equations of motion only up to the instant when the point load reaches the other end of the arch.
Skip Nav Destination
e-mail: jschen@ccms.ntu.edu.tw
Article navigation
October 2004
Technical Papers
Dynamic Snap-Through of a Shallow Arch Under a Moving Point Load
Jen-San Chen, Professor,
e-mail: jschen@ccms.ntu.edu.tw
Jen-San Chen, Professor
Department of Mechanical Engineering, National Taiwan University, Taipei, Taiwan 10617
Search for other works by this author on:
Jian-San Lin, Graduate Student
Jian-San Lin, Graduate Student
Department of Mechanical Engineering, National Taiwan University, Taipei, Taiwan 10617
Search for other works by this author on:
Jen-San Chen, Professor
Department of Mechanical Engineering, National Taiwan University, Taipei, Taiwan 10617
e-mail: jschen@ccms.ntu.edu.tw
Jian-San Lin, Graduate Student
Department of Mechanical Engineering, National Taiwan University, Taipei, Taiwan 10617
Contributed by the Technical Committee on Vibration and Sound for publication in the JOURNAL OF VIBRATION AND ACOUSTICS. Manuscript received October 2002; final revision, March 2004. Associate Editor: Chin An Tan.
J. Vib. Acoust. Oct 2004, 126(4): 514-519 (6 pages)
Published Online: December 21, 2004
Article history
Received:
October 1, 2002
Revised:
March 1, 2004
Online:
December 21, 2004
Citation
Chen, J., and Lin, J. (December 21, 2004). "Dynamic Snap-Through of a Shallow Arch Under a Moving Point Load ." ASME. J. Vib. Acoust. October 2004; 126(4): 514–519. https://doi.org/10.1115/1.1804991
Download citation file:
Get Email Alerts
Related Articles
Numerical Stability Criteria for Localized Post-buckling Solutions in a Strut-on-Foundation Model
J. Appl. Mech (May,2004)
Snapping of Low Pinned Arches on an Elastic Foundation
J. Appl. Mech (September,1973)
The Buckling of Spherical Liposomes
J Biomech Eng (December,2005)
Exact Critical Loads for a Pinned Half-Sine Arch Under End Couples
J. Appl. Mech (January,2005)
Related Proceedings Papers
Related Chapters
Members in Compression
Design & Analysis of ASME Boiler and Pressure Vessel Components in the Creep Range
Subsection NB—Class 1 Components
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 1, Third Edition
IMPLICATIONS OF LIMIT STATE DESIGN CHECKS FOR GEOTECHNICAL LOADS
Pipeline Integrity Management Under Geohazard Conditions (PIMG)