Researchers in gas turbine field take great interest in the cooling performance on the first-stage vane because of the complex flow characteristics and intensive heat load that comes from the exit of the combustion chamber. A better understanding is needed on how the coolant flow interacts with the mainstream and the resulting cooling effect in the real engine especially for the first-stage vane. An authentic flow channel and condition should be achieved. In this study, three full-scale turbine vanes are used to construct an annular-sector cascade. The film-cooling design is attained through numerous layback fan-shaped and cylindrical holes dispersed on the vane and both endwalls. With the three-dimensional vane geometry and corresponding wind tunnel design, the true flow field can thus be simulated as in the engine. This study targets the film-cooling effectiveness on the inner endwall (hub) of turbine vane. Tests are performed under the mainstream Reynolds number 350,000; the related inlet Mach number is 0.09; and the freestream turbulence intensity is 8%. Two variables, coolant-to-mainstream mass flow ratios (MFR = 2%, 3%, and 4%) and density ratios (DR = 1.0 and 1.5), are examined. Pressure-sensitive paint (PSP) technique is utilized to capture the detail contour of film-cooling effectiveness on the inner endwall and demonstrate the coolant trace. The presented results serve as a comparison basis for other sets of vanes with different cooling designs. The results are expected to strengthen the promise of PSP technique on evaluating the film-cooling performance of the engine geometries.
Full-Scale Turbine Vane Endwall Film-Cooling Effectiveness Distribution Using Pressure-Sensitive Paint Technique
Department of Mechanical Engineering,
Texas A&M University,
College Station, TX 77843-3123
e-mail: joeshiau@tamu.edu
Department of Mechanical Engineering,
Texas A&M University,
College Station, TX 77843-3123
e-mail: myandychen@tamu.edu
Department of Mechanical Engineering,
Texas A&M University,
College Station, TX 77843-3123
e-mail: jc-han@tamu.edu
Department of Mechanical Engineering,
Texas A&M University,
College Station, TX 77843-3123
e-mail: joeshiau@tamu.edu
Department of Mechanical Engineering,
Texas A&M University,
College Station, TX 77843-3123
e-mail: myandychen@tamu.edu
Department of Mechanical Engineering,
Texas A&M University,
College Station, TX 77843-3123
e-mail: jc-han@tamu.edu
Contributed by the International Gas Turbine Institute (IGTI) of ASME for publication in the JOURNAL OF TURBOMACHINERY. Manuscript received November 9, 2015; final manuscript received November 24, 2015; published online January 12, 2016. Editor: Kenneth C. Hall.
Permission for use: The content of this paper is copyrighted by Siemens Energy, Inc. and is licensed to ASME for publication and distribution only. Any inquiries regarding permission to use the content of this paper, in whole or in part, for any purpose must be addressed to Siemens Energy, Inc. directly.
Shiau, C., Chen, A. F., Han, J., Azad, S., and Lee, C. (January 12, 2016). "Full-Scale Turbine Vane Endwall Film-Cooling Effectiveness Distribution Using Pressure-Sensitive Paint Technique." ASME. J. Turbomach. May 2016; 138(5): 051002. https://doi.org/10.1115/1.4032166
Download citation file: