This study numerically and experimentally examines the effects of applying curvilinear element blades to fully shrouded centrifugal impellers on the performance of the centrifugal compressor stages. The curvilinear element blades we developed for centrifugal turbomachinery were defined by the coordinate transformations between a revolutionary flow-coordinate system and a cylindrical coordinate system. All the blade sections in the transferred cylindrical coordinate system were moved and stacked spanwise in accordance with the given “lean profile,” which meant the spanwise distribution profile of movement of the blade sections, to form a new leaned blade surface. The effects of the curvilinear element blades on the impeller flowfield were investigated using numerical simulations, and the optimum design guidelines for impellers with curvilinear element blades were considered. Then, a new impeller using these design guidelines was designed and the performance improvement of a new compressor stage was evaluated by numerical simulations. As mentioned in several papers, we numerically confirmed that curvilinear element blades with a negative tangential lean (TGL) profile improved the velocity distribution and stage efficiency because they help to suppress the secondary flows in the impeller. The negative TGL mentioned in this paper represents the lean profile in which the blade hub end leans forward in the direction of the impeller rotation compared to the blade shroud end. At the same time, we also found that the stall margin of these impellers deteriorated due to the increase in relative velocity deceleration near the suction surface of the shroud in the forward part of the impeller. Therefore, we propose new design guidelines for impellers with the curvilinear element blades by applying a negative TGL to line element blades in which the blade loading of the shroud side in the forward part of the impeller is reduced. We confirmed from the numerical simulation results that the performance of the new compressor stage improved compared to that in the corresponding conventional one. The new design guidelines for the curvilinear element blades were experimentally verified by comparing the performance of the new compressor stage with the corresponding conventional one. The measured efficiency of the new compressor stage was 2.4% higher than that of the conventional stage with the stall margin kept comparable. A comparison of the measured velocity distributions at the impeller exit showed that the velocity distribution of the new impeller was much more uniform than that of the conventional one.
Skip Nav Destination
Article navigation
Research-Article
Proposal and Experimental Verification of Design Guidelines for Centrifugal Compressor Impellers With Curvilinear Element Blades to Improve Compressor Performance
Kiyotaka Hiradate,
Kiyotaka Hiradate
Hitachi Research Laboratory,
Advanced Simulation Research Department,
Mechanical Engineering Research Center,
e-mail: Kiyotaka.hiradate.kf@hitachi.com
Advanced Simulation Research Department,
Mechanical Engineering Research Center,
Hitachi, Ltd.
,832-2 Horiguchi
,Hitachinaka, Ibaraki 312-0034
, Japan
e-mail: Kiyotaka.hiradate.kf@hitachi.com
Search for other works by this author on:
Hiromi Kobayashi,
Hiromi Kobayashi
Fluid Dynamics R&D Department,
Turbomachinery R&D Center,
Infrastructure System Company,
e-mail: hiromi.kobayashi.zm@hitachi.com
Turbomachinery R&D Center,
Infrastructure System Company,
Hitachi, Ltd.
,603 Kandatsu
,Tsuchiura, Ibaraki 300-0013
, Japan
e-mail: hiromi.kobayashi.zm@hitachi.com
Search for other works by this author on:
Kazuyuki Sugimura,
Kazuyuki Sugimura
Hitachi Research Laboratory,
Reliability Science Research Department,
Mechanical Engineering Research Center,
e-mail: kazuyuki.sugimura.hk@hitachi.com
Reliability Science Research Department,
Mechanical Engineering Research Center,
Hitachi, Ltd.
,832-2 Horiguchi
,Hitachinaka, Ibaraki 312-0034
, Japan
e-mail: kazuyuki.sugimura.hk@hitachi.com
Search for other works by this author on:
Toshio Ito,
Toshio Ito
Compressor Division,
Compressor Design Department,
Tsuchiura Works,
Infrastructure System Company,
e-mail: toshio.ito.wa@hitachi.com
Compressor Design Department,
Tsuchiura Works,
Infrastructure System Company,
Hitachi, Ltd.
,603 Kandatsu
,Tsuchiura, Ibaraki 300-0013
, Japan
e-mail: toshio.ito.wa@hitachi.com
Search for other works by this author on:
Hideo Nishida
Hideo Nishida
Compressor Division,
Compressor Design Department,
Tsuchiura Works,
Infrastructure System Company,
e-mail: Hideo.nishida.cr@hitachi.com
Compressor Design Department,
Tsuchiura Works,
Infrastructure System Company,
Hitachi, Ltd.
,603 Kandatsu
,Tsuchiura, Ibaraki 300-0013
, Japan
e-mail: Hideo.nishida.cr@hitachi.com
Search for other works by this author on:
Kiyotaka Hiradate
Hitachi Research Laboratory,
Advanced Simulation Research Department,
Mechanical Engineering Research Center,
e-mail: Kiyotaka.hiradate.kf@hitachi.com
Advanced Simulation Research Department,
Mechanical Engineering Research Center,
Hitachi, Ltd.
,832-2 Horiguchi
,Hitachinaka, Ibaraki 312-0034
, Japan
e-mail: Kiyotaka.hiradate.kf@hitachi.com
Hiromi Kobayashi
Fluid Dynamics R&D Department,
Turbomachinery R&D Center,
Infrastructure System Company,
e-mail: hiromi.kobayashi.zm@hitachi.com
Turbomachinery R&D Center,
Infrastructure System Company,
Hitachi, Ltd.
,603 Kandatsu
,Tsuchiura, Ibaraki 300-0013
, Japan
e-mail: hiromi.kobayashi.zm@hitachi.com
Kazuyuki Sugimura
Hitachi Research Laboratory,
Reliability Science Research Department,
Mechanical Engineering Research Center,
e-mail: kazuyuki.sugimura.hk@hitachi.com
Reliability Science Research Department,
Mechanical Engineering Research Center,
Hitachi, Ltd.
,832-2 Horiguchi
,Hitachinaka, Ibaraki 312-0034
, Japan
e-mail: kazuyuki.sugimura.hk@hitachi.com
Toshio Ito
Compressor Division,
Compressor Design Department,
Tsuchiura Works,
Infrastructure System Company,
e-mail: toshio.ito.wa@hitachi.com
Compressor Design Department,
Tsuchiura Works,
Infrastructure System Company,
Hitachi, Ltd.
,603 Kandatsu
,Tsuchiura, Ibaraki 300-0013
, Japan
e-mail: toshio.ito.wa@hitachi.com
Hideo Nishida
Compressor Division,
Compressor Design Department,
Tsuchiura Works,
Infrastructure System Company,
e-mail: Hideo.nishida.cr@hitachi.com
Compressor Design Department,
Tsuchiura Works,
Infrastructure System Company,
Hitachi, Ltd.
,603 Kandatsu
,Tsuchiura, Ibaraki 300-0013
, Japan
e-mail: Hideo.nishida.cr@hitachi.com
Contributed by the International Gas Turbine Institute (IGTI) of ASME for publication in the JOURNAL OF TURBOMACHINERY. Manuscript received August 26, 2014; final manuscript received September 8, 2014; published online November 18, 2014. Editor: Ronald Bunker.
J. Turbomach. May 2015, 137(5): 051008 (11 pages)
Published Online: May 1, 2015
Article history
Received:
August 26, 2014
Revision Received:
September 8, 2014
Online:
November 18, 2014
Citation
Hiradate, K., Kobayashi, H., Sugimura, K., Ito, T., and Nishida, H. (May 1, 2015). "Proposal and Experimental Verification of Design Guidelines for Centrifugal Compressor Impellers With Curvilinear Element Blades to Improve Compressor Performance." ASME. J. Turbomach. May 2015; 137(5): 051008. https://doi.org/10.1115/1.4028650
Download citation file:
Get Email Alerts
Related Articles
Aerodynamic Optimization of a Transonic Centrifugal Compressor by Using Arbitrary Blade Surfaces
J. Turbomach (May,2018)
An Investigation of Nonlinear Flow Oscillations in a High-Pressure Centrifugal Pump
J. Turbomach (November,2015)
Loss and Deviation in Windmilling Fans
J. Turbomach (October,2016)
Characterizing the Influence of Impeller Exit Recirculation on Centrifugal Compressor Work Input
J. Turbomach (January,2018)
Related Proceedings Papers
Related Chapters
Introduction
Mixed-flow Pumps: Modeling, Simulation, and Measurements
Aerodynamic Performance Analysis
Axial-Flow Compressors
Other Components and Variations
Axial-Flow Compressors