Back-to-back testing was done using NASA fan rotor 67 in the Glenn Research Center W8 Axial Compressor Test Facility. The rotor was baseline tested with a normal industrial root-mean-square (RMS) surface finish of 0.5 μm to 0.6 μm (20 microinches to 24 microinches) at 60, 80, and 100% of design speed. At design speed the tip relative Mach number was 1.38. The blades were then removed from the facility and ultrapolished to a surface finish of 0.125 μm (5 microinch) or less and retested. At 100% speed near the design point, the ultrapolished blades showed approximately 0.3% to 0.5% increase in adiabatic efficiency. The difference was greater near maximum flow. Due to increased relative measurement error at 60 and 80% speed, the performance difference between the normal and ultrapolished blades was indeterminate at these speeds.
Skip Nav Destination
e-mail: bbclipper@hotmail.com
Glenn Research Center,
e-mail: Anthony.J.Strazisar@nasa.gov
Article navigation
January 2013
Research-Article
The Effect of Ultrapolish on a Transonic Axial Rotor
William B. Roberts,
e-mail: bbclipper@hotmail.com
William B. Roberts
Airfoil Technologies International and Flow Application Research
,Freemont, CA 94539
e-mail: bbclipper@hotmail.com
Search for other works by this author on:
Scott A. Thorp,
Scott A. Thorp
National Aeronautics and Space Administration,
e-mail: Scott.A.Thorp@nasa.gov
Glenn Research Center
,Cleveland, OH 44135
e-mail: Scott.A.Thorp@nasa.gov
Search for other works by this author on:
Anthony J. Strazisar
Glenn Research Center,
e-mail: Anthony.J.Strazisar@nasa.gov
Anthony J. Strazisar
National Aeronautics and Space Administration
,Glenn Research Center,
Cleveland, OH 44135
e-mail: Anthony.J.Strazisar@nasa.gov
Search for other works by this author on:
William B. Roberts
Airfoil Technologies International and Flow Application Research
,Freemont, CA 94539
e-mail: bbclipper@hotmail.com
Scott A. Thorp
National Aeronautics and Space Administration,
e-mail: Scott.A.Thorp@nasa.gov
Glenn Research Center
,Cleveland, OH 44135
e-mail: Scott.A.Thorp@nasa.gov
Patricia S. Prahst
Anthony J. Strazisar
National Aeronautics and Space Administration
,Glenn Research Center,
Cleveland, OH 44135
e-mail: Anthony.J.Strazisar@nasa.gov
Contributed by International Gas Turbine Institute (IGTI) of ASME for publication in JOURNAL OF TURBOMACHINERY. Manuscript received April 7, 2011; final manuscript received August 24, 2011 published online October 12, 2012. Editor: David Wisler.
J. Turbomach. Jan 2013, 135(1): 011001 (6 pages)
Published Online: October 12, 2012
Article history
Received:
April 7, 2011
Revision Received:
August 24, 2011
Citation
Roberts, W. B., Thorp, S. A., Prahst, P. S., and Strazisar, A. J. (October 12, 2012). "The Effect of Ultrapolish on a Transonic Axial Rotor." ASME. J. Turbomach. January 2013; 135(1): 011001. https://doi.org/10.1115/1.4006496
Download citation file:
Get Email Alerts
Cited By
Film Cooling Comparison of Full-Scale Turbine Vanes Using the Pressure Sensitive Paint Technique
J. Turbomach (September 2023)
Related Articles
Control of Tip-Clearance Flow in a Low Speed Axial Compressor Rotor With Plasma Actuation
J. Turbomach (March,2012)
Discussion: “Criteria for Spike Initiated Rotating Stall” ( Vo, H. D., Tan, C. S., Greitzer, E. M., 2008, ASME J. Turbomach., 130, p. 011023 )
J. Turbomach (January,2008)
Investigation of Blade Tip Interaction With Casing Treatment in a Transonic Compressor—Part II: Numerical Results
J. Turbomach (January,2011)
Prediction of the Nonuniform Tip Clearance Effect on the Axial Compressor Flow Field
J. Fluids Eng (May,2010)
Related Chapters
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Aerodynamic Performance Analysis
Axial-Flow Compressors
Other Components and Variations
Axial-Flow Compressors