The aspirating probe has recently been successfully used to measure entropy within a turbomachine; however, it was found that its sensitivity to total pressure and total temperature fluctuations was significantly altered at high frequencies. If the aspirating probe is to be used to measure unsteady flow fields accurately, these high-frequency effects must be better understood. The analysis of this behavior presented here shows that there are three effects that must be considered: the frequency response of the hot wires, the presence of Mach number fluctuations inside the probe, and the change in heat transfer from the hot wires at high frequencies. A theoretical analysis of the first effect has provided a correction factor that can be used for any hot wire, dependent solely on the baseline heat transfer ratio, the overheat ratio, and the time constant of the hot wires. The second and third effects have been examined numerically, since no theoretical solution is known to exist. The Mach number fluctuations are found to be well predicted by a simple one-dimensional solver and to show a variation of ±2.4% in Mach number at the hot-wire plane for the geometry and flow field considered here. The variation in heat transfer with frequency is found to be negligible at high overheat ratios, but significant at overheat ratios below 0.4. Coefficients that determine how the measured total pressure and total temperature depend on the actual total pressure, total temperature, and Mach number have been derived, and these show significant variation with the values of the two overheat ratios. Using synthetic data, based on previous experimental data, the effects on the probe measurement accuracy are analyzed. This shows that the amplitudes of total pressure and total temperature are reduced. At widely spaced overheat ratios, the amplitudes are reduced by similar amounts, but at smaller spacing the reductions become dissimilar, resulting in highly erroneous entropy∕R measurements. High-frequency effects thus have a significant effect on the performance of the aspirating probe and should be carefully considered when using it in a highly unsteady flow field.

1.
Denton
,
J. D.
, 1993, “
Loss Mechanisms in Turbomachines
,”
ASME J. Turbomach.
0889-504X,
115
, pp.
621
656
.
2.
Ng
,
W. F.
, and
Epstein
,
A. H.
, 1983, “
High-Frequency Temperature and Pressure Probe for Unsteady Compressible Flows
,”
Rev. Sci. Instrum.
0034-6748,
54
, pp.
1678
1683
.
3.
Buttsworth
,
D. R.
,
Jones
,
T. V.
, and
Chana
,
K. S.
, 1998, “
Unsteady Total Temperature Measurements Downstream of a High Pressure Turbine
,”
ASME J. Turbomach.
0889-504X,
120
, pp.
760
767
.
4.
Payne
,
S. J.
,
Ainsworth
,
R. W.
,
Miller
,
R. J.
,
Moss
,
R. W.
, and
Harvey
,
N. W.
, 2003, “
Unsteady Loss in a High Pressure Turbine Stage
,”
Int. J. Heat Fluid Flow
0142-727X,
24
, pp.
698
708
.
5.
Ng
,
W. F.
, and
Epstein
,
A. H.
, 1985, “
Unsteady Losses in Transonic Compressors
,”
ASME J. Eng. Gas Turbines Power
0742-4795,
107
, pp.
345
353
.
6.
Alday
,
J.
,
Osborne
,
D. J.
,
Morris
,
B.
,
Ng
,
W.
, and
Gertz
,
J.
, 1993, “
Flow Randomness and Tip Losses in Transonic Rotors
,” ASME Paper No. 93-GT-189.
7.
Van Zante
,
D. E.
,
Suder
,
K. L.
,
Strazisar
,
A. J.
, and
Okiishi
,
T. H.
, 1995, “
An Improved Aspirating Probe for Total-Temperature and Total-pressure Measurements in Compressor Flows
,”
ASME J. Turbomach.
0889-504X,
117
, pp.
642
649
.
8.
Suryavamshi
,
N.
,
Lakshminarayana
,
B.
, and
Prato
,
J.
, 1996, “
Aspirating Probe Measurements of the Unsteady Total Temperature Field Downstream of an Embedded Stator in a Multistage Axial Flow Compressor
,” ASME Paper No. 96-GT-543.
9.
Brouckaert
,
J. F.
, 1998, “
Experience With a Double-Hot-Wire Aspirating Probe in a Transonic Turbine Stage
,”
Proc. of 14th Symposium on Measuring Techniques for Transonic and Supersonic Flows in Cascades in Turbomachinery
,
Limerick
.
10.
Payne
,
S. J.
, 2001, “
Unsteady Loss in a High Pressure Turbine Stage
,” D. Phil. thesis, University of Oxford.
11.
Bruun
,
H. H.
, 1995,
Hot-Wire Anemometry: Principles and Signal Analysis
,
Oxford University Press
,
London
.
12.
Collis
,
D. C.
, and
Williams
,
M. J.
, 1959, “
Two-Dimensional Convection From Heated Wires at Low Reynolds Numbers
,”
J. Fluid Mech.
0022-1120,
6
, pp.
357
389
.
13.
Højstrup
,
J.
,
Rasmussen
,
K.
, and
Larsen
,
S. E.
, 1976, “
Dynamic Calibration of Temperature Wires in Still Air
,”
DISA Inf.
,
20
, pp.
22
30
.
14.
Freymuth
,
P.
, 1979, “
Engineering Estimate of Heat Conduction Loss in Constant Temperature Thermal Sensors
,”
TSI Q.
,
V
(
3
), pp.
3
9
.
15.
Parantheon
,
P.
,
Lecordier
,
J. C.
, and
Petit
,
C.
, 1983, “
Dynamic Sensitivity of the Constant-temperature Hot-Sire Anemometer to Temperature Fluctuations
,”
TSI Q.
,
9
, pp.
3
8
.
16.
Dewey
,
C. F.
, 1965, “
A Correlation of Convective Heat Transfer and Recovery Temperature Data or Cylinders in Compressible Flow
,”
Int. J. Heat Mass Transfer
0017-9310,
8
, pp.
245
252
.
17.
Shapiro
,
A. H.
, 1957,
The Dynamics and Thermodynamics of Compressible Fluid Flow
,
Wiley
,
New York
, Vol.
2
.
18.
LeVeque
,
R. J.
, 2002,
Finite Volume Methods for Hyperbolic Problems
,
Cambridge University Press
,
Cambridge, England
.
19.
LeVeque
,
R. J.
, 1992,
Numerical Methods for Conservation Laws
,
Birkhauser
,
Boston
.
You do not currently have access to this content.