Pulsed film cooling was studied experimentally to determine its effect on film-cooling effectiveness. The film-cooling jets were pulsed using solenoid valves in the supply air line. Cases with a single row of cylindrical film-cooling holes inclined at 35 deg to the surface of a flat plate were considered at blowing ratios of 0.25, 0.5, 1.0, and 1.5 for a variety of pulsing frequencies and duty cycles. Temperature measurements were made using an infrared camera, thermocouples, and cold-wire anemometry. Hot-wire anemometry was used for velocity measurements. The local film-cooling effectiveness was calculated based on the measured temperatures, and the results were compared to baseline cases with continuous blowing. Phase-locked flow temperature fields were determined from cold-wire surveys. Pulsing at high frequencies helped to improve film-cooling effectiveness in some cases by reducing overall jet liftoff. At lower frequencies, pulsing tended to have the opposite effect. With the present geometry and a steady mainflow, pulsing did not provide an overall benefit. The highest overall effectiveness was achieved with continuous jets and a blowing ratio of 0.5. The present results may prove useful for understanding film-cooling behavior in engines, where mainflow unsteadiness causes film-cooling jet pulsation.
Skip Nav Destination
volino@usna.edu
Article navigation
April 2007
Technical Papers
Effect of Jet Pulsing on Film Cooling—Part I: Effectiveness and Flow-Field Temperature Results
Sarah M. Coulthard,
Sarah M. Coulthard
Department of Mechanical Engineering,
Stanford University
, Stanford, CA 94305
Search for other works by this author on:
Ralph J. Volino,
Ralph J. Volino
Department of Mechanical Engineering,
volino@usna.edu
United States Naval Academy
, Annapolis, MD 21402
Search for other works by this author on:
Karen A. Flack
Karen A. Flack
Department of Mechanical Engineering,
United States Naval Academy
, Annapolis, MD 21402
Search for other works by this author on:
Sarah M. Coulthard
Department of Mechanical Engineering,
Stanford University
, Stanford, CA 94305
Ralph J. Volino
Department of Mechanical Engineering,
United States Naval Academy
, Annapolis, MD 21402volino@usna.edu
Karen A. Flack
Department of Mechanical Engineering,
United States Naval Academy
, Annapolis, MD 21402J. Turbomach. Apr 2007, 129(2): 232-246 (15 pages)
Published Online: May 31, 2006
Article history
Received:
May 25, 2006
Revised:
May 31, 2006
Connected Content
A correction has been published:
Effect of Jet Pulsing on Film Cooling—Part II: Heat Transfer Results
Citation
Coulthard, S. M., Volino, R. J., and Flack, K. A. (May 31, 2006). "Effect of Jet Pulsing on Film Cooling—Part I: Effectiveness and Flow-Field Temperature Results." ASME. J. Turbomach. April 2007; 129(2): 232–246. https://doi.org/10.1115/1.2437231
Download citation file:
Get Email Alerts
Cited By
Related Articles
Effect of Jet Pulsing on Film Cooling—Part II: Heat Transfer Results
J. Turbomach (April,2007)
Effect of Jet Pulsation and Duty Cycle on Film Cooling From a Single Jet on a Leading Edge Model
J. Turbomach (July,2006)
Film Effectiveness Downstream of a Row of Compound Angle Film Holes
J. Heat Transfer (April,2005)
Measurements in Film Cooling Flows With Periodic Wakes
J. Turbomach (October,2008)
Related Chapters
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Thermodynamic Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential