Thermodynamic and aerodynamic measurements were carried out in a linear turbine cascade with transonic flow field. Heat transfer and adiabatic film-cooling effectiveness resulting from the interaction of the flow field and the ejected coolant at the endwall were measured and will be discussed in two parts. The investigations were performed in the Windtunnel for Straight Cascades (EGG) at the DLR, Goettingen. The film-cooled NGV endwall was operated at representative dimensionless engine conditions of Mach and Reynolds number and respectively. Part II of the paper discusses the thermodynamic measurements. Detailed temperature measurements were carried out on a turbine stator endwall. In order to determine the surface heat transfer and adiabatic film-cooling effectiveness, an infrared camera system in a rectilinear wind tunnel measured the endwall temperatures in the transonic flow field. The adiabatic film-cooling effectiveness was determined using the superposition method. Measurements were carried out to first, validate the assumptions of theory and second, analyze the error associated with the measurements. Effects of coolant ejection from a slot and three rows of holes were investigated and compared with each other. The influence of Mach number and blowing ratio on the heat transfer were further aspects of the investigation. Strong variations in heat transfer and film-cooling effectiveness due to the interaction of the coolant air and the secondary flow field were found. Based on the results of this investigation an improved cooling design will be investigated in a follow-up project.
Skip Nav Destination
Article navigation
October 2001
Technical Papers
Film-Cooled Turbine Endwall in a Transonic Flow Field: Part II—Heat Transfer and Film-Cooling Effectiveness
Martin Nicklas
Martin Nicklas
Institute of Propulsion Technology, German Aerospace Center (DLR), 37073 Go¨ttingen, Germany
Search for other works by this author on:
Martin Nicklas
Institute of Propulsion Technology, German Aerospace Center (DLR), 37073 Go¨ttingen, Germany
Contributed by the International Gas Turbine Institute and presented at the 46th International Gas Turbine and Aeroengine Congress and Exhibition, New Orleans, Louisiana, June 4–7, 2001. Manuscript received by the International Gas Turbine Institute February 2001. Paper No. 2001-GT-146. Review Chair: R. Natole.
J. Turbomach. Oct 2001, 123(4): 720-729 (10 pages)
Published Online: February 1, 2001
Article history
Received:
February 1, 2001
Citation
Nicklas, M. (February 1, 2001). "Film-Cooled Turbine Endwall in a Transonic Flow Field: Part II—Heat Transfer and Film-Cooling Effectiveness ." ASME. J. Turbomach. October 2001; 123(4): 720–729. https://doi.org/10.1115/1.1397308
Download citation file:
Get Email Alerts
Related Articles
Effects of a Reacting Cross-Stream on Turbine Film Cooling
J. Eng. Gas Turbines Power (May,2010)
A Three-Dimensional Coupled Internal/External Simulation of a Film-Cooled Turbine Vane
J. Turbomach (April,2000)
Film Cooling Effectiveness and Heat Transfer Coefficient Distributions Around Diffusion Shaped Holes
J. Heat Transfer (October,2002)
Related Proceedings Papers
Related Chapters
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Thermodynamic Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
EVALUATION OF THERMAL PROBE COOLING EFFECT BASED ON PIPELINE PARALLEL OPTICAL CABLE
Pipeline Integrity Management Under Geohazard Conditions (PIMG)