Film-cooling effectiveness was studied using a row of inclined holes that injected cryogenically cooled air across a flat, adiabatic test plate. The density ratio of the coolant to mainstream varied from 1.2 to 2.0. Surface temperatures were measured using a unique surface thermocouple arrangement free of conduction errors. Temperatures were obtained along the jet centerline and across a number of lateral locations. By independently varying density ratio and blowing rate, scaling of adiabatic effectiveness with mass flux ratio, velocity ratio, and momentum ratio was determined. Depending on the momentum flux ratio, the jet either remains attached to the surface, detaches and then reattaches, or is fully detached. For attached jets, the centerline effectiveness scaled with the mass flux ratio. However, for detached-reattached jets, a consistent scaling was not found although the general distribution of the centerline effectiveness scaled with momentum flux ratio. Laterally averaged effectiveness was found to be dependent on density ratio and momentum flux ratio. Decreases in density ratio and increases in momentum flux ratio were found to reduce the spreading of the film cooling jet significantly and thereby reduce laterally averaged effectiveness.
Skip Nav Destination
Article navigation
July 1991
Research Papers
Film-Cooling Effectiveness Downstream of a Single Row of Holes With Variable Density Ratio
A. K. Sinha,
A. K. Sinha
Mechanical Engineering Department, University of Texas at Austin, Austin, TX 78712
Search for other works by this author on:
D. G. Bogard,
D. G. Bogard
Mechanical Engineering Department, University of Texas at Austin, Austin, TX 78712
Search for other works by this author on:
M. E. Crawford
M. E. Crawford
Mechanical Engineering Department, University of Texas at Austin, Austin, TX 78712
Search for other works by this author on:
A. K. Sinha
Mechanical Engineering Department, University of Texas at Austin, Austin, TX 78712
D. G. Bogard
Mechanical Engineering Department, University of Texas at Austin, Austin, TX 78712
M. E. Crawford
Mechanical Engineering Department, University of Texas at Austin, Austin, TX 78712
J. Turbomach. Jul 1991, 113(3): 442-449 (8 pages)
Published Online: July 1, 1991
Article history
Received:
January 11, 1990
Online:
June 9, 2008
Citation
Sinha, A. K., Bogard, D. G., and Crawford, M. E. (July 1, 1991). "Film-Cooling Effectiveness Downstream of a Single Row of Holes With Variable Density Ratio." ASME. J. Turbomach. July 1991; 113(3): 442–449. https://doi.org/10.1115/1.2927894
Download citation file:
Get Email Alerts
Related Articles
Film Effectiveness Downstream of a Row of Compound Angle Film Holes
J. Heat Transfer (April,2005)
High-Resolution Film Cooling Effectiveness Measurements of Axial Holes Embedded in a Transverse Trench With Various Trench Configurations
J. Turbomach (April,2007)
The Effect of Internal Crossflow on the Adiabatic Effectiveness of Compound Angle Film Cooling Holes
J. Turbomach (July,2015)
Compound Triple Jets Film Cooling Improvements via Velocity and Density Ratios: Large Eddy Simulation
J. Fluids Eng (March,2011)
Related Proceedings Papers
Related Chapters
Analysis of Shutdown Mode at BarsebÄck 2; an Approach to a Combined PSA, HFA and Deterministic Analysis (PSAM-0117)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
Understanding The Systematic Error of a Mineral-Insulated, Metal Sheathed (MIMS) Thermocouple Attached to a Heated Flat Surface
Thermal Measurements: The Foundation of Fire Standards
Studies Performed
Closed-Cycle Gas Turbines: Operating Experience and Future Potential