Circular translation pin-on-disk (CTPOD) tests were performed for ultrahigh molecular weight polyethylene (UHMWPE) with a view to reproducing wear mechanisms that prevail in total hip prostheses. The contact surface diameter varied from 3.0 mm to 30 mm, while the slide track diameter was fixed, 10 mm. The counterface was polished CoCr, and the lubricant was diluted alpha calf serum. Either the nominal contact pressure (1.1 MPa) or the load (126 N) was kept constant. With a constant contact pressure, the wear factor decreased steeply when the contact diameter exceeded the slide track diameter, apparently because the wear debris was not readily conveyed away from the contact. With constant load, both the wear factor and the coefficient of friction increased linearly with increasing contact area. This trend was in agreement with clinical observations that the wear rate of UHMWPE acetabular cups increased with increasing femoral head size. With nominal contact pressures approaching 10 MPa however, the bearing surface topography markedly differed from clinical observations. This was probably due to overheating of the contact and plastic deformation that resulted in the formation of protuberances not seen clinically. The present study emphasized the importance of test parameters in the pin-on-disk wear screening of prosthetic joint materials. It appeared that the contact surface diameter of the flat-on-flat test should be below the slide track diameter, and that the nominal contact pressure should be of the order of 1 MPa.
Skip Nav Destination
Article navigation
November 2017
Research-Article
Effect of Contact Area on the Wear and Friction of UHMWPE in Circular Translation Pin-on-Disk Tests
Vesa Saikko
Vesa Saikko
Department of Mechanical Engineering,
Aalto University School of Engineering,
P.O. Box 14300,
Aalto FI-00076, Finland
e-mail: vesa.saikko@aalto.fi
Aalto University School of Engineering,
P.O. Box 14300,
Aalto FI-00076, Finland
e-mail: vesa.saikko@aalto.fi
Search for other works by this author on:
Vesa Saikko
Department of Mechanical Engineering,
Aalto University School of Engineering,
P.O. Box 14300,
Aalto FI-00076, Finland
e-mail: vesa.saikko@aalto.fi
Aalto University School of Engineering,
P.O. Box 14300,
Aalto FI-00076, Finland
e-mail: vesa.saikko@aalto.fi
Contributed by the Tribology Division of ASME for publication in the JOURNAL OF TRIBOLOGY. Manuscript received October 7, 2016; final manuscript received March 9, 2017; published online July 10, 2017. Assoc. Editor: Zhong Min Jin.
J. Tribol. Nov 2017, 139(6): 061606 (5 pages)
Published Online: July 10, 2017
Article history
Received:
October 7, 2016
Revised:
March 9, 2017
Citation
Saikko, V. (July 10, 2017). "Effect of Contact Area on the Wear and Friction of UHMWPE in Circular Translation Pin-on-Disk Tests." ASME. J. Tribol. November 2017; 139(6): 061606. https://doi.org/10.1115/1.4036448
Download citation file:
Get Email Alerts
Related Articles
Experimental and Computational Thermal Modeling of In Vitro Pin-on-Disk Tests of Ultra High Molecular Weight Polyethylene
J. Tribol (October,2016)
Surface Texturing of Prosthetic Hip Implant Bearing Surfaces: A Review
J. Tribol (April,2021)
Related Proceedings Papers
Related Chapters
Materials
Design and Application of the Worm Gear
Surface Analysis and Tools
Tribology of Mechanical Systems: A Guide to Present and Future Technologies
Chapter 46 | Lubrication Fundamentals
Fuels and Lubricants Handbook: Technology, Properties, Performance, and Testing