This paper presents a model study of inductive, capacitive, and piezoelectric effects on the accuracy of pressure measurements in an EHD contact. Circuit and mathematical models of a thin-layer sensor and a measurement system were developed. It has been assumed that isolation layers of the sensor, deposited as SiOx (1 ≤ x ≤ 2) layers, have piezoelectric properties. The circuit model of the sensor contains a resistance, an electric capacitance, an inductance of a sensor’s circuit, and an ideal current source representing piezoelectric properties of isolating layers of the sensor. The circuit model of the measurement system forms a full measuring bridge with the thin-layer sensor in one of its branches. A derived equation for output voltage of the measurement bridge was used as a mathematical model of the measurement system. The investigations show that at inappropriate electric parameters of the measurement system, inappropriate shape of the sensor’s transducer and short transition time of the sensor through the contact zone, the capacitive, and piezoelectric effects have a significant impact on the accuracy of pressure measurement in the EHD contact. The transducer with an active part located along its connection edges (asymmetric transducer) and a transducer with the active part located in the middle of connections width (symmetric transducer) was tested. It was shown that in the case of the symmetric transducer, the pressure measurement signal change caused by the capacitive and piezoelectric effects, is much smaller than in the case of the asymmetric transducer.
Skip Nav Destination
e-mail: adam.wilczek@pr.radom.pl
Article navigation
July 2011
Research Papers
Influence of Electrical Parameters of a Thin-Layer Sensor on the Accuracy of Pressure Measurement in an EHD Contact
Adam Wilczek
e-mail: adam.wilczek@pr.radom.pl
Adam Wilczek
Faculty of Mechanical Engineering, Technical University of Radom
, ul. Krasickiego 54, 26-600 Radom, Poland
Search for other works by this author on:
Adam Wilczek
Faculty of Mechanical Engineering, Technical University of Radom
, ul. Krasickiego 54, 26-600 Radom, Poland
e-mail: adam.wilczek@pr.radom.pl
J. Tribol. Jul 2011, 133(3): 031504 (8 pages)
Published Online: July 28, 2011
Article history
Received:
March 14, 2011
Revised:
May 29, 2011
Accepted:
June 6, 2011
Online:
July 28, 2011
Published:
July 28, 2011
Citation
Wilczek, A. (July 28, 2011). "Influence of Electrical Parameters of a Thin-Layer Sensor on the Accuracy of Pressure Measurement in an EHD Contact." ASME. J. Tribol. July 2011; 133(3): 031504. https://doi.org/10.1115/1.4004345
Download citation file:
Get Email Alerts
Cited By
Related Articles
Interaction of Rim Seal and Annulus Flows in an Axial Flow Turbine
J. Eng. Gas Turbines Power (October,2004)
The Influence of Construction Features of a Thin-Layer Sensor on Pressure Distributions Recorded in an Elastohydrodynamic Contact
J. Tribol (January,2012)
A Self-Energized Sensor for Wireless Injection Mold Cavity Pressure Measurement: Design and Evaluation
J. Dyn. Sys., Meas., Control (June,2004)
Experimental Analysis of a Waveguide Pressure Measuring System
J. Eng. Gas Turbines Power (April,2010)
Related Proceedings Papers
Related Chapters
Experimental Investigation of Ventilated Supercavitation Under Unsteady Conditions
Proceedings of the 10th International Symposium on Cavitation (CAV2018)
Introduction
Vibrations of Linear Piezostructures
Linear Piezoelectricity
Vibrations of Linear Piezostructures