The established biaxial rocking motion (BRM) hip joint simulator was complemented by a novel friction measurement accessory. This simple and practical system, which was easily added to an existing BRM design, is described in detail and shown to perform well in long-term wear tests and in comparative tests of 24 h duration involving several different bearing couples. The system was based on the measurement of frictional torque about the leaning axis of the lower component, the femoral head. In the 28 mm CoCr-on-ultrahigh molecular weight polyethylene articulation with diluted calf serum lubricant at body temperature and 1 kN static load, the maximum value of frictional torque during a cycle was 1.2 N m on the average. The alternative system based on the measurement of torque about the vertical loading axis was shown to be less sensitive and highly insensitive when contact area was small, as was the case with alumina-on-alumina.

1.
McKellop
,
H. A.
, and
Clarke
,
I. C.
, 1985, “
Degradation and Wear of Ultra-High-Molecular-Weight Polyethylene
,”
Proceedings of the Corrosion and Degradation of Implant Materials: Second Symposium
, ASTM STP 859,
A. C.
Fraker
and
C. D.
Griffin
, eds.,
American Society for Testing and Materials
,
Philadelphia
, pp.
351
368
.
2.
Bowsher
,
J. G.
, and
Shelton
,
J. C.
, 2001, “
A Hip Simulator Study of the Influence of Patient Activity Level on the Wear of Crosslinked Polyethylene Under Smooth and Roughened Femoral Conditions
,”
Wear
0043-1648,
250
(
1–12
), pp.
167
179
.
3.
Liao
,
Y.-S.
,
McKellop
,
H.
,
Lu
,
Z.
,
Campbell
,
P.
, and
Benya
,
P.
, 2003, “
The Effect of Frictional Heating and Forced Cooling on the Serum Lubricant and Wear of UHMW Polyethylene Cups Against Cobalt-Chromium and Zirconia Balls
,”
Biomaterials
0142-9612,
24
(
18
), pp.
3047
3059
.
4.
Unsworth
,
A.
,
Pearcy
,
M. J.
,
White
,
E. F. T.
, and
White
,
G.
, 1988, “
Frictional Properties of Artificial Hip Joints
,”
Eng. Med.
0046-2039,
17
(
3
), pp.
101
104
.
5.
Saikko
,
V.
, 1992, “
A Simulator Study of Friction in Total Replacement Hip Joints
,”
Proc. Inst. Mech. Eng., Part H: J. Eng. Med.
0954-4119,
206
(
4
), pp.
201
211
.
6.
Wang
,
A.
,
Essner
,
A.
, and
Klein
,
R.
, 2001, “
Effect of Contact Stress on Friction and Wear of Ultra-High Molecular Weight Polyethylene in Total Hip Replacement
,”
Proc. Inst. Mech. Eng., Part H: J. Eng. Med.
0954-4119,
215
(
2
), pp.
133
139
.
7.
Bergmann
,
G.
,
Graichen
,
F.
,
Rohlmann
,
A.
,
Verdonschot
,
N.
, and
van Lenthe
,
G. H.
, 2001, “
Frictional Heating of Total Hip Implants
,”
J. Biomech.
0021-9290,
34
(
4
), pp.
421
435
.
8.
Saikko
,
V.
, and
Calonius
,
O.
, 2002, “
Slide Track Analysis of the Relative Motion Between Femoral Head and Acetabular Cup in Walking and in Hip Simulators
,”
J. Biomech.
0021-9290,
35
(
4
), pp.
455
464
.
9.
Calonius
,
O.
, and
Saikko
,
V.
, 2002, “
Slide Track Analysis of Eight Contemporary Hip Simulator Designs
,”
J. Biomech.
0021-9290,
35
(
11
), pp.
1439
1450
.
10.
Saikko
,
V.
, and
Ahlroos
,
T.
, 1999, “
Type of Motion and Lubricant in Wear Simulation of Polyethylene Acetabular Cup
,”
Proc. Inst. Mech. Eng., Part H: J. Eng. Med.
0954-4119,
213
(
4
), pp.
301
310
.
11.
Saikko
,
V.
,
Ahlroos
,
T.
,
Calonius
,
O.
, and
Keränen
,
J.
, 2001, “
Wear Simulation of Total Hip Prostheses With Polyethylene Against CoCr, Alumina and Diamond-Like Carbon
,”
Biomaterials
0142-9612,
22
(
12
), pp.
1507
1514
.
12.
Saikko
,
V.
,
Calonius
,
O.
, and
Keränen
,
J.
, 2002, “
Wear of Conventional and Cross-Linked Ultra-High-Molecular-Weight Polyethylene Acetabular Cups Against Polished and Roughened CoCr Femoral Heads in a Biaxial Hip Simulator
,”
J. Biomed. Mater. Res., Part B: Appl. Biomater.
1552-4973,
63
(
6
), pp.
848
853
.
13.
Saikko
,
V.
, and
Pfaff
,
H.-G.
, 1998, “
Low Wear and Friction in Alumina/Alumina Total Hip Joints: A Hip Simulator Study
,”
Acta Orthop. Scand.
,
69
(
5
), pp.
443
448
. 0001-6470
14.
McKellop
,
H. A.
,
Campbell
,
P.
,
Park
,
S.-H.
,
Schmalzried
,
T. P.
,
Grigoris
,
P.
,
Amstutz
,
H. C.
, and
Sarmiento
,
A.
, 1995, “
The Origin of Submicron Polyethylene Wear Debris in Total Hip Arthroplasty
,”
Clin. Orthop. Relat. Res.
,
311
, pp.
3
20
. 0009-921X
15.
Saikko
,
V.
, 2006, “
Effect of Contact Pressure on Wear and Friction of Ultra-High Molecular Weight Polyethylene in Multidirectional Sliding
,”
Proc. Inst. Mech. Eng., Part H: J. Eng. Med.
0954-4119,
220
(
7
), pp.
723
731
.
16.
Restrepo
,
C.
,
Parvizi
,
J.
,
Kurz
,
S. M.
,
Sharkey
,
P. F.
,
Hozack
,
W. J.
, and
Rothman
,
R. H.
, 2008, “
The Noisy Ceramic Hip: Is Component Malpositioning the Cause?
,”
J. Arthroplasty
,
23
(
5
), pp.
643
649
. 0883-5403
You do not currently have access to this content.