This paper describes the influence of lubrication on wear during testing of materials for artificial knee joints in a rolling∕sliding tribotester built to simulate contact conditions in a total knee replacement. The test configuration consists of parallel cylinders (pucks) of ultrahigh molecular weight polyethylene (UHMWPE) and polished cobalt-chrome alloy in oscillatory rolling∕sliding contact in a bath of dilute (25%) bovine serum. Wear tests of three different UHMWPE materials were run under constant load at 40% sliding for 1.5 million oscillation cycles at 1.5cycless. Wear of the UHMWPE was determined by measuring the profile of the cylindrical contact surface of the puck before and after each test. Profile measurements were repeated after at least 53days to eliminate the contribution from creep. Differences between initial and final profiles were attributed to wear of the UHMWPE. It was found that the largest wear depth in the lubricated tests occurred near the ends of the oscillatory contact area, while dry (unlubricated) tests of the same materials showed a peak wear depth near the center of the contact area. In the lubricated tests, the worn depth was lowest for the most heavily irradiated material. Analysis of the elastohydrodynamic lubrication in the rolling∕sliding contact was carried out assuming a line-contact situation with smooth cylindrical surfaces. The time-dependent modified Reynolds equation and the elasticity equation with initial conditions were solved numerically using a multigrid technique with full approximation scheme, and using a Newton Raphson method to solve the highly nonlinear system of equations. The thickness of the lubricating film of bovine serum was determined for points along the length of the wear track. It was found that the smallest film thickness (hmin) occurs very close to the location in the oscillating contact where the greatest wear occurs, owing to the very low entraining velocity near the ends of the oscillation cycle. The coefficient (K) for wear of the UHMWPE was found to be relatively constant over the central section of the oscillatory motion, but increased to a higher value where hmin decreased to near zero. Thus, the important influence of lubrication on wear of artificial knee bearings was demonstrated.

1.
Kurtz
,
S.
,
Mowat
,
F.
,
Ong
,
K.
,
Chan
,
N.
,
Lau
,
E.
, and
Halpern
,
M.
, 2005, “
Prevalence of Primary and Revision Total Hip and Knee Arthroplasty in the United States From 1990 Through 2002
,”
J. Bone Jt. Surg., Am. Vol.
0021-9355,
87
, pp.
1487
1497
.
2.
Sharkey
,
P. F.
,
Hozack
,
W. J.
,
Rothman
,
R. H.
,
Shastri
,
S.
, and
Jacoby
,
S. M.
, 2002, “
Why Are Total Knee Arthroplasties Failing Today?
,”
Clin. Orthop. Relat. Res.
0009-921X,
404
, pp.
7
13
.
3.
Hood
,
R. W.
,
Wright
,
T. M.
, and
Burstein
,
A. H.
, 1983, “
Retrieval Analysis of Total Knee Prostheses: A Method and Its Application to 48 Total Condylar Prostheses
,”
J. Biomed. Mater. Res.
0021-9304,
17
, pp.
829
842
.
4.
Collier
,
J. P.
,
Sperling
,
D. K.
,
Currier
,
J. H.
,
Sutula
,
L. C.
,
Saum
,
K. A.
, and
Mayor
,
M. B.
, 1996, “
Impact of Gamma Sterilization on Clinical Performance of Polyethylene in the Knee
,”
J. Arthroplasty
0883-5403,
11
, pp.
377
389
.
5.
Kennedy
,
F. E.
,
Currier
,
B. H.
,
Van Citters
,
D. W.
,
Currier
,
J. H.
,
Collier
,
J. P.
, and
Mayor
,
M. B.
, 2003, “
Oxidation of Ultra-High Molecular Weight Polyethylene and Its Influence on Contact Fatigue and Pitting of Knee Bearings
,”
Tribol. Trans.
1040-2004,
46
, pp.
111
118
.
6.
Reeves
,
E. A.
,
Barton
,
D. C.
,
Fisher
,
J.
, and
FitzPatrick
,
D.
, 2000, “
Comparison of Gas Plasma and Gamma Irradiation in Air Sterilization on the Delamination Wear of the Ultra-High Molecular Weight Polyethylene Used in Knee Replacements
,”
Proc. Inst. Mech. Eng., Part H: J. Eng. Med.
0954-4119,
214
, pp.
249
255
.
7.
Collier
,
J. P.
,
Currier
,
B. H.
,
Kennedy
,
F. E.
,
Currier
,
J. H.
,
Timmins
,
G.
,
Jackson
,
S. K.
, and
Brewer
,
R. L.
, 2003, “
Comparison of Cross-Linked Polyethylene Materials for Orthopedic Applications
,”
Clin. Orthop. Relat. Res.
0009-921X,
414
, pp.
289
304
.
8.
Jordan
,
L. R.
, and
Olivio
,
J. L.
, 2002, “
Aseptic Loosening in the LCS Total Knee Arthroplasty
,”
LCS: Mobile Bearing Knee Arthroplasty
,
Hamelynck
,
K. J.
, ed.,
Springer
,
New York
, pp.
253
259
.
9.
Ingham
,
E.
, and
Fisher
,
J.
, 2000, “
Biological Reactions to Wear Debris in Total Joint Replacement
,”
Proc. Inst. Mech. Eng., Part H: J. Eng. Med.
0954-4119,
214
, pp.
21
37
.
10.
Fisher
,
J.
,
McEwen
,
H. M.
,
Tipper
,
J. L.
,
Galvin
,
A. L.
,
Ingram
,
J.
,
Kamali
,
A.
,
Stone
,
M. H.
,
Martin
,
H.
, and
Ingham
,
E.
, 2004, “
Wear, Debris, and Biologic Activity of Cross-Linked Polyethylene in the Knee: Benefits and Potential Concerns
,”
Clin. Orthop. Relat. Res.
0009-921X,
428
, pp.
114
119
.
11.
McGloughlin
,
T. M.
, and
Kavanagh
,
A. G.
, 2000, “
Wear of Ultra-High Molecular Weight Polyethylene (UHMWPE) in Total Knee Prostheses: A Review of Key Influences
,”
Proc. Inst. Mech. Eng., Part H: J. Eng. Med.
0954-4119,
214
, pp.
349
359
.
12.
Walker
,
P. S.
,
Blunn
,
G. W.
, and
Lilley
,
P. A.
, 1996, “
Wear Testing of Materials and Surfaces for Total Knee Replacement
,”
J. Biomed. Mater. Res.
0021-9304,
33
, pp.
159
175
.
13.
Banks
,
S. A.
, and
Hodge
,
W. A.
, 1996, “
Accurate Measurement of Three-Dimensional Knee Replacement Kinematics Using Single Plane Fluoroscopy
,”
IEEE Trans. Biomed. Eng.
0018-9294,
43
, pp.
638
649
.
14.
Hamilton
,
M. A.
,
Sucec
,
M. C.
,
Fregly
,
B. J.
,
Banks
,
S. A.
, and
Sawyer
,
W. G.
, 2005, “
Quantifying Multidirectional Sliding Motions in Total Knee Replacements
,”
ASME J. Tribol.
0742-4787,
127
, pp.
280
286
.
15.
Kennedy
,
F. E.
,
Currier
,
J. H.
, and
Wong
,
B.
, 2001, “
Tribotesting of Tibial Bearings of Knee Prostheses
,”
Tribology Research: From Model Experiment to Industrial Problem
,
G.
Dalmaz
,
A. A.
Lubrecht
,
D.
Dowson
, and
M.
Priest
, eds.,
Elsevier Science
,
Amsterdam
, pp.
371
379
.
16.
Van Citters
,
D. W.
,
Kennedy
,
F. E.
,
Currier
,
J. H.
,
Collier
,
J. P.
, and
Nichols
,
T. D.
, 2004, “
A Multi-Station Rolling∕Sliding Tribotester for Knee Bearing Materials
,”
ASME J. Tribol.
0742-4787,
126
, pp.
380
385
.
17.
Muratoglu
,
O. K.
,
Perinchief
,
R. S.
,
Bragdon
,
C. R.
,
O’Connor
,
D. O.
,
Konrad
,
R.
, and
Harris
,
W. H.
, 2003, “
Metrology to Quantify Wear and Creep of Polyethylene Tibial Knee Inserts
,”
Clin. Orthop. Relat. Res.
0009-921X,
410
, pp.
158
164
.
18.
Raimondi
,
M. T.
,
Santambrogio
,
C.
,
Pietrabissa
,
R.
,
Raffelini
,
F.
, and
Mofetta
,
L.
, 2001, “
Improved Mathematical Model of the Wear of the Cup Articular Surface in Hip Joint Prostheses and Comparison With Retrieved Components
,”
Proc. Inst. Mech. Eng., Part H: J. Eng. Med.
0954-4119,
215
, pp.
377
391
.
19.
Kang
,
I.
,
Galvin
,
A. L.
,
Jin
,
Z. M.
, and
Fisher
,
J.
, 2006, “
A Simple Fully Integrated Contact-Coupled Wear Prediction for Ultra-High Molecular Weight Polyethylene Hip Implants
,”
Proc. Inst. Mech. Eng., Part H: J. Eng. Med.
0954-4119,
220
, pp.
33
46
.
20.
Fregly
,
B. J.
,
Sawyer
,
W. G.
,
Harman
,
M. K.
, and
Banks
,
S. A.
, 2005, “
Computational Wear Prediction of a Total Knee Replacement From In Vivo Kinematics
,”
J. Biomech.
0021-9290,
38
, pp.
305
314
.
21.
Zhao
,
D.
,
Fregly
,
B. J.
, and
Sawyer
,
W. G.
, 2005, “
Dynamic Simulation of a Simulator Machine for Knee Implant Damage Prediction
,”
Proc. Knee Arthoplasty Technical Conf.
,
IMechE
,
London, England
, pp.
237
240
.
22.
Vassiliou
,
K.
, and
Unsworth
,
A.
, 2004, “
Is the Wear Factor in Total Joint Replacements Dependent on the Nominal Contact Stress in Ultra-High Molecular Weight Polyethylene Contacts?
,”
Proc. Inst. Mech. Eng., Part H: J. Eng. Med.
0954-4119,
218
, pp.
101
107
.
23.
Sathasivam
,
S.
,
Walker
,
P. S.
,
Campbell
,
P. A.
, and
Rayner
,
K.
, 2001, “
The Effect of Contact Area on Wear in Relation to Fixed Bearing and Mobile Bearing Knee Replacements
,”
J. Biomed. Mater. Res.
0021-9304,
58
, pp.
282
290
.
24.
Rabinowicz
,
E.
, 1980, “
Wear Coefficients—Metals
,”
Wear Control Handbook
,
Peterson
,
M. B.
and
Winer
,
W. O.
, eds.,
ASME
,
New York
, pp.
475
506
.
25.
Scholes
,
S. C.
,
Unsworth
,
A.
, and
Goldsmith
,
A. A. J.
, 2000, “
A Frictional Study of Total Hip Replacements
,”
Phys. Med. Biol.
0031-9155,
45
, pp.
3721
3735
.
26.
Hamrock
,
B. J.
, and
Dowson
,
D.
, 1978, “
Elastohydrodynamic Lubrication of Elliptical Contacts for Materials of Low Elastic Modulus—1: Fully Flooded Conjunction
,”
ASME J. Lubr. Technol.
0022-2305,
100
, pp.
236
245
.
27.
Jalali-Vahid
,
D.
,
Jagatia
,
M.
,
Jin
,
Z. M.
, and
Dowson
,
D.
, 2001, “
Prediction of Lubricating Film Thickness in UHMWPE Hip Joint Replacements
,”
J. Biomech.
0021-9290,
34
, pp.
261
266
.
28.
Wang
,
F. C.
,
Liu
,
F.
, and
Jin
,
Z. M.
, 2004, “
A General Elastohydrodynamic Lubrication Analysis of Artificial Hip Joints Employing a Compliant Layered Socket Under Steady State Rotation
,”
Proc. Inst. Mech. Eng., Part H: J. Eng. Med.
0954-4119,
218
, pp.
283
291
.
29.
Kennedy
,
F. E.
,
Currier
,
J. H.
,
Plumet
,
S.
,
Duda
,
J. L.
,
Gestwick
,
D. P.
,
Collier
,
J. P.
,
Currier
,
B. H.
, and
Dubourg
,
M. C.
, 2000, “
Contact Fatigue Failure of Ultra-High Molecular Weight Polyethylene Bearing Components of Knee Prostheses
,”
ASME J. Tribol.
0742-4787,
122
, pp.
332
339
.
30.
Hamrock
,
B. J.
, 1994,
Fundamentals of Fluid Film Lubrication
,
McGraw-Hill
,
Singapore
.
31.
Lubrecht
,
A. A.
,
ten Napel
,
W. E.
, and
Bosma
,
R.
, 1986, “
Multigrid, an Alternative Method for Calculating Film Thickness and Pressure Profiles in Elastohydrodynamically Lubricated Line Contacts
,”
ASME J. Tribol.
0742-4787,
108
, pp.
551
556
.
32.
Johnson
,
K. L.
, 1985,
Contact Mechanics
,
Cambridge University Press
,
Cambridge, England
.
33.
Spikes
,
H.
, 2000, “
The Borderline of Elastohydrodynamic and Boundary Lubrication
,”
J. Mech. Eng. Sci.
0022-2542,
214
, pp.
23
37
.
34.
Patir
,
N.
, and
Cheng
,
H.
, 1978, “
An Average Flow Model for Determining Effects of Three Dimensional Roughness on Partial Hydrodynamic Lubrication
,”
ASME J. Lubr. Technol.
0022-2305,
100
, pp.
12
17
.
You do not currently have access to this content.