Fifty-seven measurements of the minimum lubricant film thickness separating the elastohydrodynamically lubricated point contact of a steel crowned roller and a flat sapphire disk were made by an optical interferometry technique. The data collected were used to evaluate the Hamrock and Dowson minimum EHD film thickness model over a practical range of contact ellipticity ratio where the major axis of the contact ellipse is aligned both parallel and perpendicular to the direction of motion. A statistical analysis of the measured film thickness data showed that the experimental data averaged 30 percent greater film thickness than the Hamrock and Dowson model predicts.

This content is only available via PDF.
You do not currently have access to this content.