In cooling towers packed with trickle or splash fills, which have anisotropic flow resistance, the air flow through the fill is oblique or in cross-counterflow to the water flow, particularly at the cooling tower inlet when the fill loss coefficient is small or when the fill hangs down into the air inlet region. This results in that the fill Merkel number or transfer characteristic for cross-counter flow is between that of purely counter- and crossflow fills. When using CFD to model natural draught wet-cooling tower performance for isotropic fill resistance, two- or three-dimensional models are therefore required to determine fill performance. In this paper, the governing fundamental partial differential equations are derived in cylindrical and Cartesian coordinates to determine the cooling water temperature, water evaporation rate, air temperature, and air humidity ratio in two-dimensional cross-counterflow fills for both saturated and supersaturated air. To solve these equations, a relation is proposed to determine Merkel numbers for oblique air flows by linear interpolation and extrapolation of purely cross- and counterflow Merkel numbers in terms of the air flow angle. This model is compared to analytical Merkel numbers obtained for different air flow angles using a single drop trajectory model. A linear upwind computational model and an Eulerian FLUENT® model are developed to evaluate fill performance characteristics from test data and to model fill performance in cooling towers, respectively. The results of these two models are compared and verified with a FLUENT Euler–Lagrange model, showing minor deviations.
Skip Nav Destination
Article navigation
June 2012
Research Papers
Computational Models for Predicting Cooling Tower Fill Performance in Cross-Counterflow Configuration
D. G. Kröger
D. G. Kröger
Emeritus professor
Department of Mechanical and Mechatronic Engineering,
University of Stellenbosch
, Private Bag X1, Matieland, 7602, South Africa
Search for other works by this author on:
H. C. R. Reuter
Associate professor
D. G. Kröger
Emeritus professor
Department of Mechanical and Mechatronic Engineering,
University of Stellenbosch
, Private Bag X1, Matieland, 7602, South Africa
J. Thermal Sci. Eng. Appl. Jun 2012, 4(2): 021003 (9 pages)
Published Online: April 16, 2012
Article history
Received:
July 4, 2011
Revised:
November 18, 2011
Online:
April 16, 2012
Published:
April 16, 2012
Citation
Reuter, H. C. R., and Kröger, D. G. (April 16, 2012). "Computational Models for Predicting Cooling Tower Fill Performance in Cross-Counterflow Configuration." ASME. J. Thermal Sci. Eng. Appl. June 2012; 4(2): 021003. https://doi.org/10.1115/1.4006028
Download citation file:
Get Email Alerts
Cited By
A cooling efficiency model and Numerical research of multi-parameter film cooling
J. Thermal Sci. Eng. Appl
Energy Saving Optimization of Chilled Water System Based on Improved Fruit Fly Optimization Algorithm
J. Thermal Sci. Eng. Appl (August 2023)
Computational Study of Heat Exchange and Thermal Oxidative Coking of Supercritical-Pressure Kerosene With Compressed Air in Counterflows
J. Thermal Sci. Eng. Appl (August 2023)
Related Articles
An Analytical Approach to the Heat and Mass Transfer Processes in Counterflow Cooling Towers
J. Heat Transfer (November,2006)
An Improved Design and Rating Analyses of Counter Flow Wet Cooling Towers
J. Heat Transfer (August,2001)
On the Merkel Equation: Novel ε-Number of Transfer Unit Correlations for Indirect Evaporative Cooler Under Different Lewis Numbers
J. Thermal Sci. Eng. Appl (December,2017)
Computational Fluid Dynamics Analysis of Cooling Tower Inlets
J. Fluids Eng (August,2011)
Related Proceedings Papers
Related Chapters
Economic Considerations and Drivers
Thermal Power Plant Cooling: Context and Engineering
Basics of Hydraulic Loops
Hydraulics, Pipe Flow, Industrial HVAC & Utility Systems: Mister Mech Mentor, Vol. 1
Condensers and Cooling Towers
Handbook for Cogeneration and Combined Cycle Power Plants, Second Edition