Data centers consume an extraordinary amount of electricity, and the rate of consumption is increasing at a rapid pace. Thus, energy efficiency in data center design is of substantial interest since it can have a significant impact on operating costs. The server cooling infrastructure is one area which is ripe for design innovation. Various designs have been considered for air-cooled data centers, and there is growing interest in liquid-cooled server designs. One potential liquid-cooled solution, which reduces the cost of cooling to less than 5% of the information technology (IT) energy use, is a chiller-less or warm water-cooled system, which removes the chiller from the design and lets the cooling water supply vary with changes in the outdoor ambient conditions. While this design has been proven to work effectively in some locations, environmental extremes prevent its more widespread implementation. In this paper, the design and analysis of a cold water storage system are shown to extend the applicability of chiller-less designs to a wider variety of environmental conditions. This can lead to both energy and economic savings for a wide variety of data center installations. A numerical model of a water storage system is developed, validated, and used to analyze the impact of a water storage tank system in a chiller-less data center design featuring outdoor wet cooling. The results show that during times of high wet bulb operating conditions, a water storage tank can be an effective method to significantly reduce chip operating temperatures for warm water-cooled systems by reducing operating temperatures 5–7 °C during the hottest part of the day. The overall system performance was evaluated using both an exergy analysis and a modified power usage effectiveness (PUE) metric defined for the water storage system. This unique situation also necessitates the development of a new exergy definition in order to properly capture the physics of the situation. The impacts of tank size, tank aspect ratio, fill percentage, and charging/discharging time on both the chip temperature and modified PUE are evaluated. It is determined that tank charging time must be carefully matched to environmental conditions in order to optimize impact. Interestingly, the water being stored is initially above ambient, but the overall system performance improves with lower water temperatures. Therefore, heat losses to ambient are found to beneficial to the overall system performance. The results of this analysis demonstrate that in application, data center operators will see a clear performance benefit if water storage systems are used in conjunction with warm water cooling. This application can be extended to data center failure scenarios and could also lead to downsizing of equipment and a clear economic benefit.

References

References
1.
NRDC
,
2014
,
America's Data Centers are Wasting Huge Amounts of Energy
,
Natural Resources Defense Council
,
New York
.
2.
ASHRAE
,
2009
, “
Datacom Series 6, Best Practices for DataCom Facility Energy Efficiency
,” 2nd ed., American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, GA.
3.
Ellsworth, M. J.
,
Campbell
,
L. A.
,
Simons
,
R. E.
,
Iyengar
,
M. K.
,
Schmidt
,
R. R.
, and
Chu
,
R. C.
,
2008
, “
The Evolution of Water Cooling for IBM Large Server Systems: Back to the Future
,”
Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems
, Orlando, FL, May 28–31, pp. 266–274
4.
Ellsworth
,
M. J.
,
Goth
,
G. F.
,
Zoodsma
,
R. J.
,
Arvelo
,
A.
,
Campbell
,
L. A.
, and
Anderl
,
W. J.
,
2011
, “
An Overview of the Power 775 Supercomputer Water Cooling System
,”
ASME
Paper No. IPACK2011-52130.
5.
Ellsworth
,
M.
, and
Iyengar
,
M. K.
,
2009
, “
Energy Efficiency Analyses and Comparison of Air and Water Cooled High Performance Servers
,”
ASME
Paper No. IPACK2009-89248.
6.
David
,
M.
,
Iyengar
,
M.
,
Parida
,
P.
,
Simons
,
R.
,
Schultz
,
M.
,
Gaynes
,
M.
,
Schmidt
,
R.
, and
Chainer
,
T.
,
2012
, “
Experimental Characterization of an Energy Efficient Chiller-Less Data Center Test Facility With Warm Water Cooled Servers
,” 28th Annual IEEE Semiconductor Thermal Measurement and Management Symposium (
SEMI-THERM
), San Jose, CA, pp. 232–237.
7.
David
,
M.
,
Iyengar
,
M.
,
Parida
,
P.
,
Simons
,
R.
,
Schultz
,
M.
,
Gaynes
,
M.
,
Schmidt
,
R.
, and
Chainer
,
T.
,
2012
, “
Impact of Operating Conditions on a Chiller-Less Data Center Test Facility With Liquid Cooled Servers
,” 13th Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (
ITHERM
), San Diego, CA, May 30–June 1, pp. 562–573.
8.
Gao
,
T.
,
David
,
M.
,
Geer
,
J.
,
Schmidt
,
S.
, and
Sammakia
,
B.
,
2015
, “
Experimental and Numerical Dynamic Investigation of an Energy Efficient Liquid Cooled Chiller-Less Data Center Test Facility
,”
Energy Build.
,
91
, pp.
83
96
.
9.
Pinel
,
P.
,
Cruickshank
,
C.
,
Beausoleil-Morrison
,
I.
, and
Wills
,
A.
,
2011
, “
A Review of Available Methods for Seasonal Storage of Solar Thermal Energy in Residential Applications
,”
Renewable Sustainable Energy Rev.
,
15
(
7
), pp.
3341
3359
.
10.
De Ridder
,
F.
,
Diehl
,
M.
,
Mulder
,
G.
,
Desmedt
,
J.
, and
Van Bael
,
J.
,
2011
, “
An Optimal Control Algorithm for Borehole Thermal Energy Storage Systems
,”
Energy Build.
,
43
(
10
), pp.
2918
2925
.
11.
Dincer
,
I.
,
Sadik
,
D.
, and
Xianguo
,
L.
,
1997
, “
Performance Analyses of Sensible Heat Storage Systems for Thermal Applications
,”
Int. J. Energy Res.
,
21
(
12
), pp.
1157
1171
.
12.
Wemhoff
,
A. P.
,
del Valle
,
M.
,
Abbasi
,
K.
, and
Ortega
,
A.
,
2013
, “
Thermodynamic Modeling of Data Center Cooling Systems
,”
ASME
Paper No. IPACK2013-73116.
13.
Bhalerao
,
A.
,
Fouladi
,
K.
,
Silva-Llanca
,
L.
, and
Wemhoff
,
A. P.
,
2016
, “
Rapid Prediction of Exergy Destruction in Data Centers Due to Airflow Mixing
,”
Numer. Heat Transfer, Part A
,
70
(
1
), pp.
48
63
.
14.
Fouladi
,
K.
,
Wemhoff
,
A. P.
,
Silva-Llanca
,
L.
,
Abbasi
,
K.
, and
Ortega
,
A.
,
2017
, “
Optimization of Data Center Cooling Efficiency Using Reduced Order Flow Modeling Within a Flow Network Modeling Approach
,”
Appl. Therm. Eng.
,
124
, pp.
929
939
.
15.
Fouladi
,
K.
,
Schaadt
,
J.
, and
Wemhoff
,
A. P.
,
2017
, “
A Novel Approach to the Data Center Hybrid Cooling Design With Containment
,”
Numer. Heat Transfer, Part A
,
71
(
5
), pp.
477
487
.
16.
Wemhoff
,
A. P.
, and
Ortega
,
A.
,
2014
, “
An Exergy-Based Analysis of the Effects of Rear Door Heat Exchange Systems on Data Center Energy Efficiency
,”
IEEE Thermomechanical Phenomena in Electronic Systems Conference
(
ITHERM
), Orlando, FL, May 27–30, pp.
1129
1136
.
17.
Bhalerao
,
A.
,
Ortega
,
A.
, and
Wemhoff
,
A. P.
,
2014
, “
Thermodynamic Analysis of Hybrid Liquid-Air-Based Data Center Cooling Strategies
,”
ASME
Paper No. IMECE2014-38359.
18.
Bhalerao
,
A.
, and
Wemhoff
,
A. P.
,
2015
, “
Thermodynamic Analysis of Full Liquid-Cooled Data Centers
,”
ASME
Paper No. IPACK2015-48439.
19.
Khan
,
J. U. R.
,
Yaqub
,
M.
, and
Zubair
,
S. M.
,
2003
, “
Performance Characteristics of Counter Flow Wet Cooling Towers
,”
Energy Convers. Manage.
,
44
(
13
), pp.
2073
2091
.
20.
Khan
,
J. U. R.
, and
Zubair
,
S. M.
,
2004
, “
A Study of Fouling and Its Effects on the Performance of Counter Flow Wet Cooling Towers
,”
Proc. Inst. Mech. Eng., Part E
,
218
(
1
), pp.
43
51
.
21.
Khan
,
J. U. R.
, and
Zubair
,
S. M.
,
2001
, “
An Improved Design and Rating Analyses of Counter Flow Wet Cooling Towers
,”
ASME J. Heat Transfer
,
123
(
4
), pp.
770
778
.
22.
Kloppers
,
J. C.
, and
Kröger
,
D. G.
,
2005
, “
The Lewis Factor and Its Influence on the Performance Prediction of Wet-Cooling Towers
,”
Int. J. Therm. Sci.
,
44
(
9
), pp.
879
884
.
23.
Simpson
,
W. M.
, and
Sherwood
,
T. K.
,
1946
, “
Performance of Small Mechanical Draft Cooling Towers
,”
Refrig. Eng.
52
(
6
), pp.
574
576
.
24.
Muangnoi
,
T.
,
Asvapoositkul
,
W.
, and
Wongwises
,
S.
,
2007
, “
An Exergy Analysis on the Performance of a Counterflow Wet Cooling Tower
,”
Appl. Therm. Eng.
,
27
(
5–6
), pp.
910
917
.
25.
Muangnoi
,
T.
,
Asvapoositkul
,
W.
, and
Wongwises
,
S.
,
2008
, “
Effects of Inlet Relative Humidity and Inlet Temperature on the Performance of Counterflow Wet Cooling Tower Based on Exergy Analysis
,”
Energy Convers. Manage.
,
49
(
10
), pp.
2795
2800
.
26.
Haslego
,
C.
, and
Polley
,
G.
,
2002
, “
Designing Plate-and-Frame Heat Exchangers
,”
Chem. Eng. Prog.
,
98
(
9
), pp.
32
37
.
27.
Kays
,
W. M.
, and
London
,
A. L.
,
1984
,
Compact Heat Exchangers
,
3rd ed.
,
McGraw-Hill
,
New York
.
28.
Motivair Cooling Solutions
,
2014
,
High Capacity Coolant Distribution Unit
,
Motivair Cooling Solutions
,
Amherst, MA
.
29.
Kleinbach
,
E. M.
,
Beckman
,
W. A.
, and
Klien
,
S. A.
,
1993
, “
Performance Study of One-Dimensional Models for Stratified Thermal Storage Tank
,”
Sol. Energy
,
50
(
2
), pp.
155
166
.
30.
Turner
,
P.
,
2001
,
Guide to Scientific Computing
,
CRC Press
,
Boca Raton, FL
.
31.
Wildin
,
M. W.
, and
Truman
,
C. R.
,
1985
, “
Evaluation of Stratifed Chilled Water Storage Techniques. Volume 1: Findings. Volume 2: Appendices
,” Electric Power Research Institute, Washington, DC.
32.
Jein
,
Y.
,
1986
, “
Initial Formation of a Thermocline in Stratified Storage Tanks
,”
ASHRAE Trans.
,
92
(
2
), p.
280292
.
33.
Wilden
,
M. W.
, and
Sohn
,
C. W.
,
1993
, “
Flow and Temperature Distribution in a Naturally Stratified Thermal Storage Tank
,” Construction Engineering Research Laboratory (U.S. Army), Champaign, IL, Report No. TR-FE-94/01.
You do not currently have access to this content.