Abstract
Stress relaxation data on commercially available copper-beryllium alloy 172 are presented. Test samples were subjected to strains of up to 2% and temperatures from 25 to 181°C. The data show that a high degree of relaxation occurs at higher temperatures and relaxation was found to be independent of the initial stress levels. Time-temperature plots of stress relaxation are presented for designing accelerated relaxation tests on the copper-beryllium alloy tested. The material in the tested condition is generally not used in spring applications and thus results of Austen which compare stress relaxation characteristics of copper-beryllium alloy 172 in the aged and unaged conditions are also presented.
Issue Section:
Research Papers
References
1.
Fox
, A.
, “Stress Relaxation and Fatigue of Small Diameter Wires Used for Miniature Springs
,” ASME 69-WA/Met-2, American Society of Mechanical Engineers
, New York
, 1969
.2.
Fox
, A.
, “Stress Relaxation and Fatigue of Two Electromechanical Spring Materials Strengthened by Thermomechanical Processing
,” IEEE Transactions on Parts, Materials and Packaging
, Institute of Electrical and Electronics Engineers, Vol. PMP-7
, No. 1
, 03
1971
, pp. 34
-47
.3.
Austen
, A. S.
and Taylor
, W.
, “Stress Relaxation in Beryllium Copper and Beryllium Nickel Springs
”, in Proceedings of the 1971 Fourth Annual Connector Symposium
, Electronic Connector Study Groups, Inc.
, Cherry Hill, N.J.
, 10
1971
.4.
Nordstrom
, T. V.
and Rohde
, R. W.
, “Mechanical Properties and Stress Relaxation of Beryllium Copper Alloy 25
,” Technical Report, Sandia Laboratories
, Albuquerque, N.M., 1972
.5.
Rohde
, R. W.
and Nordstrom
, T. V.
, “Stress-Relaxation of a Copper 1.87 Wt.% Beryllium Alloy
,” Materials Science and Engineering
, Vol. 12
, 1973
, pp. 179
-185
.6.
Manjoine
, M. J.
, “Measuring Stress-Relaxation by a Compliance Method
,” Journal of Materials
0022-2453, JMLSA, Vol. 6
, No. 2
, 06
1971
, pp. 253
-264
.
This content is only available via PDF.