Abstract

In this study, three different approaches are investigated for keeping the roof cool and reducing the heat flow inside a building located in Kanpur, India. In the first approach, various reflective paints are investigated and their performance degradation over a year is examined along with the cost-benefit analysis. In the second approach, the roof surface is kept wet, and due to water evaporation, the roof was kept cool. In the third approach, the effect of shading on the rooftop surface temperature is studied. It is observed that without any cooling, the rooftop temperature can rise about 20 °C above the ambient air temperature. The application of white acrylic paints can reduce this temperature rise to about 5–7 °C. However, after a year due to degradation, this temperature rise is about 10–12 °C. Using evaporative cooling the rooftop temperature can be lowered even below the ambient air temperature by about 3 °C. However, this approach will require active management of the system and consumption of water. The cost for the first two approaches is estimated to be about 5–6 Rs./sq.ft with a payback time of 2 years. Shading can reduce the temperature rise to about 5 °C. Structures meant for other purposes such as photovoltaic panels can serve the additional benefit of cooling the roof. Shading seems to be a robust and low-maintenance option, and cost analysis of structures meant primarily for shading the roof needs to be explored.

References

1.
Garg
,
V.
,
Kotharkar
,
R.
,
Sathaye
,
J.
,
Rallapalli
,
H.
,
Kulkarni
,
N.
,
Rddy
,
N.
,
Rao
,
P.
, and
Sarkar
,
A.
,
2016
, “
Assessment of the Impact of Cool Roofs in Rural Buildings in India
,”
Energy Build.
,
114
, pp.
156
163
.
2.
Garg
,
V.
,
Somal
,
S.
,
Arumugam
,
R.
, and
Bhatia
,
A.
,
2016
, “
Development for Cool Roof Calculator for India
,”
Energy Build.
,
114
, pp.
136
142
.
3.
Zingre
,
K. T.
,
Wan
,
M. P.
,
Tong
,
S.
,
Li
,
H.
,
Chang
,
V. W.-C.
,
Wong
,
S. K.
,
Toh
,
W. B. T. T.
, and
Lee
,
I. Y. L.
,
2015
, “
Modeling of Cool Roof Heat Transfer in Tropical Climate
,”
Renewable Energy
,
75
, pp.
210
223
.
4.
Zingre
,
K. T.
,
Wan
,
M. P.
,
Wong
,
S. K.
,
Toh
,
W. B. T.
, and
Lee
,
I. Y. L.
,
2015
, “
Modeling of Cool Roof Performance for Double Skin Roofs in Tropical Climate
,”
Energy
,
82
, pp.
813
826
.
5.
Shittu
,
E.
,
Stojceska
,
V.
,
Gratton
,
P.
, and
Kolokotroni
,
M.
,
2020
, “
Environmental Impact of Cool Roof Paint: Case-Study of House Retrofit in Two Hot Islands
,”
Energy Build.
,
217
, p.
11007-1-12
.
6.
Kolokotroni
,
M. M.
,
Shittu
,
E.
,
Santos
,
T.
,
Ramowski
,
L.
,
Mollard
,
A.
,
Rowe
,
K.
,
Wilson
,
E.
,
Filho
,
J. P. B.
, and
Novieto
,
D.
,
2018
, “
Cool Roofs: High Tech Low Cost Solution for Energy Efficiency and Thermal Comfort in Low Rise Low Income Houses in High Solar Radiation Countries
,”
Energy Build.
,
176
, pp.
58
70
.
7.
Stavrakakis
,
G. M.
,
Androutsopoulos
,
A. V.
, and
Vyorykka
,
J.
,
2016
, “
Experimental and Numerical Assessment of Cool-Roof Impact on Thermal and Energy Performance of a School Building in Greece
,”
Energy Build.
,
130
, pp.
64
84
.
8.
Synnefa
,
A.
,
Saliari
,
M.
, and
Santamouris
,
M.
,
2012
, “
Experimental and Numerical Assessment of the Impact of Increased Roof Reflectance on a School Building in Athens
,”
Energy Build.
,
55
, pp.
7
15
.
9.
De Masi
,
R. F.
,
Ruggiero
,
S.
, and
Vanoli
,
G. P.
,
2018
, “
Acrylic White Paint of Industrial Sector for Cool Roofing Application: Experimental Investigation of Summer Behaviour and Aging Problem Under Mediterranean Climate
,”
Sol. Energy
,
169
, pp.
468
487
.
10.
Yang
,
H.
,
Yu
,
H.
,
Ozaki
,
A.
, and
Dong
,
N.
,
2020
, “
Thermal and Energy Performance of Green Roof and Cool Roof: A Comparison Study in Shanghai Area
,”
J. Cleaner Prod.
,
267
, p.
122205-1-15
.
11.
Gao
,
Y.
,
Shi
,
D.
,
Levinson
,
R.
,
Guo
,
R.
,
Lin
,
C.
, and
Ge
,
J.
,
2017
, “
Thermal Performance and Energy Savings of White and Sedum-Tray Garden Roof: A Case Study in Chongquing Office Building
,”
Energy Build.
,
156
, pp.
343
359
.
12.
Ramamurthy
,
P.
,
Sun
,
T.
,
Rule
,
K.
, and
Bou-Zeid
,
E.
,
2015
, “
The Joint Influence of Albedo and Insulation on Roof Performance: A Modelling Study
,”
Energy Build.
,
102
, pp.
317
327
.
13.
Triano-Juarez
,
J.
,
Macias-Melo
,
E. V.
,
Hernandez-Perex
,
I.
,
Aguilar-Castro
,
K. M.
, and
Xaman
,
J.
,
2020
, “
Thermal Behaviour of a Phase Change Material in a Building Roof With and Without Reflective Coating in a Warm Humid Zone
,”
J. Build. Eng.
,
32
, p.
101648
.
14.
Guo
,
R.
,
Gao
,
Y.
,
Zhuang
,
C.
,
Heiselberg
,
P.
,
Levinson
,
R.
,
Zhao
,
X.
, and
Shi
,
D.
,
2020
, “
Optimization of Cool Roof and Night Ventilation in Office Buildings: A Case Study in Xiamen, China
,”
Renewable Energy
,
147
(
1
), pp.
2279
2294
.
15.
Ma
,
M.
,
Zhang
,
K.
,
Chen
,
L.
, and
Tang
,
S.
,
2021
, “
Analysis of the Impact of a Novel Cool Roof on Cooling Performance for a Low-Rise Prefabricated Building in China
,”
Build. Serv. Eng. Res. Technol.
,
42
(
1
), pp.
26
44
.
16.
Yew
,
M. C.
,
Yew
,
M. K.
,
Ho
,
M. L.
, and
Saw
,
L. H.
,
2021
, “
Integration of Lightweight Foam Concrete Roof, Moving-Air-Cavity, and Solar-Powered Fans for Attic Temperature Reduction
,”
Front. Built Environ.
,
6
, p.
641041
.
17.
Shanmuganathan
,
R.
,
Sekar
,
M.
,
Praveenkumar
,
T. R.
,
Pugazhendhi
,
A.
, and
Brindhadevi
,
K.
,
2021
, “
Experimental Investigation and Numerical Analysis of Energy Efficiency Building Using Phase Changing Material Coupled With Reflective Coating
,”
Int. J. Energy Res.
,
45
(
12
), pp.
17279
17290
.
18.
Meng
,
E.
,
Yang
,
J.
,
Cai
,
R.
,
Zhou
,
B.
, and
Wang
,
J.
,
2022
, “
Experimental Comparison of Summer Thermal Performance of Green Roof (GR), Double Skin Roof (DSR) and Cool Roof (CR) in Lightweight Rooms in Subtropical Climate
,”
J. Build. Phys.
,
45
(
6
), pp.
809
832
.
You do not currently have access to this content.