The design of the novel PV-Trombe wall in Hefei is theoretically processed in this paper. The area of winter air vents and width of PV-Trombe wall are determined, the effects of two improvements (thermal insulation and shading curtain) are investigated, and the different operating results for winter heating and summer cooling are also obtained. Results show that if compared to the original PV-Trombe wall, after thermal insulating, the indoor temperature increases by in winter and decreases by in summer and the electrical efficiency decreases by . After curtain shading, the indoor temperature decreases by in summer and the electrical efficiency increases by . It is recommended that thermal insulation in both winter and summer and appending a shading curtain in summer are adopted for PV-Trombe wall, especially for the diurnally used PV-Trombe wall.
Skip Nav Destination
e-mail: jijie@ustc.edu.cn
Article navigation
November 2007
Research Papers
PV-Trombe Wall Design for Buildings in Composite Climates
Jie Ji,
Jie Ji
Department of Thermal Science and Energy Engineering,
e-mail: jijie@ustc.edu.cn
University of Science and Technology of China
, Hefei, 230026, China
Search for other works by this author on:
Hua Yi,
Hua Yi
Department of Thermal Science and Energy Engineering,
University of Science and Technology of China
, Hefei, 230026, China
Search for other works by this author on:
Wei He,
Wei He
Department of Thermal Science and Energy Engineering,
University of Science and Technology of China
, Hefei, 230026, China
Search for other works by this author on:
Gang Pei
Gang Pei
Department of Thermal Science and Energy Engineering,
University of Science and Technology of China
, Hefei, 230026, China
Search for other works by this author on:
Jie Ji
Department of Thermal Science and Energy Engineering,
University of Science and Technology of China
, Hefei, 230026, Chinae-mail: jijie@ustc.edu.cn
Hua Yi
Department of Thermal Science and Energy Engineering,
University of Science and Technology of China
, Hefei, 230026, China
Wei He
Department of Thermal Science and Energy Engineering,
University of Science and Technology of China
, Hefei, 230026, China
Gang Pei
Department of Thermal Science and Energy Engineering,
University of Science and Technology of China
, Hefei, 230026, ChinaJ. Sol. Energy Eng. Nov 2007, 129(4): 431-437 (7 pages)
Published Online: November 1, 2006
Article history
Received:
October 24, 2005
Revised:
November 1, 2006
Citation
Ji, J., Yi, H., He, W., and Pei, G. (November 1, 2006). "PV-Trombe Wall Design for Buildings in Composite Climates." ASME. J. Sol. Energy Eng. November 2007; 129(4): 431–437. https://doi.org/10.1115/1.2770751
Download citation file:
Get Email Alerts
Related Articles
Effect of Retrofit Scenarios on Energy Performance and Indoor Thermal Comfort of a Typical Single-Family House in Different Climates of Morocco
J. Eng. Sustain. Bldgs. Cities (May,2021)
Comparative Study of Different Photovoltaic/Thermal Hybrid Configurations From Energetic and Exergetic Points of View: A Numerical Analysis
J. Sol. Energy Eng (December,2021)
Simulation and Model Validation of the Surface Cooling System for Improving the Power of a Photovoltaic Module
J. Sol. Energy Eng (November,2011)
Related Proceedings Papers
Related Chapters
Handy Facts Regarding Types of Thermal Insulation
Hydraulics, Pipe Flow, Industrial HVAC & Utility Systems: Mister Mech Mentor, Vol. 1
Cooling of the Solar Cells for a Compound Parabolic Concentrating Photovoltaic Systems
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)
Dynamic Cool Roofing Systems
Advanced Energy Efficient Building Envelope Systems