Induced passive ventilation was studied in a small field structure, about 60cm×30cm×85cm in size, heated by solar irradiation. The structure has three stories, connected by a vertical duct, which in turn is connected to a horizontal duct above the upper level of the structure. The outer walls of these two ducts are metal sheets painted on the outside with black matte paint and covered by glass sheets. The other outer walls and inner partitions of the structure are made of cardboard attached to a metal frame. Additional elements included in some experiments were a water tank, used for heat storage, and a chimney for enhancing air flow. The structure orientation was with its vertical metal sheet facing south-west. Experimental study, based on temperature and velocity measurement, and computer simulations, using the FLUENT software, were performed. During a typical experiment, the structure has been exposed to the sun for a full day in July through November. The ports of the system were either opened in the morning, or kept closed until about 13:45-14:00 and then opened. The results of the study indicate that effective ventilation has been achieved: the calculated rates of air change inside the stories were rather high, and the mean air temperatures were only about 1-2°C above the ambient in its lower stories and 2-3°C above the ambient in the upper story. Detailed comparison of the experimental and numerical results is presented and discussed.

1.
Nahar
,
N. M.
,
Sharma
,
P.
, and
Purohit
,
M. M.
,
2003
, “
Performance of Different Passive Techniques for Cooling of Buildings in Arid Regions
,”
Build. Environ.
,
38
, pp.
109
116
.
2.
Khedari
,
J.
,
Mansirisub
,
W.
,
Chaima
,
S.
,
Pratinthong
,
N.
, and
Hirunlabh
,
J.
,
2002
, “
Field Measurements of Performance of Roof Solar Collector
,”
Energy Build.
,
31
, pp.
171
178
.
3.
Hirunlabh
,
J.
,
Kongduang
,
W.
,
Namprakai
,
P.
, and
Khedari
,
J.
,
1999
, “
Study of Natural Ventilation of Houses by a Metallic Solar Wall Under Tropical Climate
,”
Renewable Energy
,
18
, pp.
109
119
.
4.
Khedari
,
J.
,
Boonsri
,
B.
, and
Hirunlabh
,
J.
,
2000
, “
Ventilation Impact of a Solar Chimney on Indoor Temperature Fluctuation and Air Change in a School Building
,”
Energy Build.
,
32
, pp.
89
93
.
5.
Afonso
,
C.
, and
Oliveira
,
A.
,
2000
, “
Solar Chimneys: Simulation and Experiment
,”
Energy Build.
,
32
, pp.
71
79
.
6.
Gan
,
G.
,
1998
, “
A Parametric Study of Trombe Walls for Passive Cooling of Buildings
,”
Energy Build.
,
27
, pp.
37
43
.
7.
Linden
,
P. F.
,
1999
, “
The Fluid Mechanics of Natural Ventilation
,”
Annu. Rev. Fluid Mech.
,
31
, pp.
231
238
.
8.
Axley, J. W., 1998, “Introduction to the Design of Natural Ventilation Systems Using Loop Equations,” Proc. 19th AIVC Conf., “Ventilation Technologies in Urban Areas,” Oslo, Norway, 28–30 September 1998, pp. 47–56.
9.
Axley, J. W., 1999, “Natural Ventilation Design Using Loop Equations,” in Indoor Air 99, Edinburgh: ISIAQ & AIVC.
10.
Axley, J. W., “Design and Simulation of Natural Ventilation Systems Using Loop Equations,” in Healthy Buildings 2000, Espoo, Finland: FiSIAQ & ISIAQ.
11.
Hunt
,
G. R.
, and
Linden
,
P. F.
,
2001
, “
Steady-State Flows in an Enclosure Ventilated by Buoyancy Forces Assisted by Wind
,”
J. Fluid Mech.
,
426
, pp.
355
386
.
12.
Li
,
Y.
,
Delsante
,
A.
,
Chen
,
Z.
,
Sandberg
,
M.
,
Andersen
,
A.
,
Bjerre
,
M.
, and
Heiselberg
,
P.
,
2001
, “
Some Examples of Solution Multiplicity in Natural Ventilation
,”
Build. Environ.
,
36
, pp.
851
858
.
13.
Dubovsky
,
V.
,
Ziskind
,
G.
,
Druckman
,
S.
,
Moshka
,
E.
,
Weiss
,
Y.
, and
Letan
,
R.
,
2001
, “
Natural Convection inside Ventilated Enclosure Heated by Downward-Facing Plate: Experiments and Numerical Simulations
,”
Int. J. Heat Mass Transfer
,
44
, pp.
3155
3168
.
14.
Ziskind
,
G.
,
Dubovsky
,
V.
, and
Letan
,
R.
,
2002
, “
Ventilation by Natural Convection of a One-Story Building
,”
Energy Build.
,
34
, pp.
91
102
.
15.
Drori, U., and Ziskind, G., 2004, “Induced Ventilation of a One-Story Real-Size Building,” Energy Build, in press.
16.
Letan
,
R.
,
Dubovsky
,
V.
, and
Ziskind
,
G.
,
2003
, “
Passive Ventilation and Heating by Natural Convection in a Multi-Story Building
,”
Build. Environ.
,
38
, pp.
197
208
.
17.
Holman, J. P., 1989, Heat Transfer, SI metric ed., McGraw-Hill, New York.
18.
Kazansky
,
S.
,
Dubovsky
,
V.
,
Ziskind
,
G.
, and
Letan
,
R.
,
2003
, “
Chimney-Enhanced Natural Convection from a Vertical Plate: Experiments and Numerical Simulations
,”
Int. J. Heat Mass Transfer
,
46
, pp.
497
512
.
19.
Farber, A., 2003, “Chimney Effect on Heat Transfer Rates in Induced Convection,” Graduation Project 03-32 (under the supervision of R. Letan and G. Ziskind), Heat Transfer Laboratory, Department of Mechanical Engineering, Ben-Gurion University of the Negev, Beer-Sheva.
20.
Ziskind
,
G.
,
Dubovsky
,
V.
, and
Letan
,
R.
,
2002
, “
Removal of Contaminants from Underground Spaces by Induced Passive Ventilation
,”
J. Environ. Eng. (Am. Soc. Civ. Eng.)
,
128
, pp.
673
688
.
21.
Ziskind, G., Dubovsky, V., and Letan, R., 2001, “Radiation and Induced Convection in Ventilated Enclosures,” Proceedings of the 2001 ASME IMECE, v. 1, paper HTD-24305, November 11–16, 2001, New York, NY.
You do not currently have access to this content.