A large portion of the installation cost of a ground-coupled heat pump system is for the excavation necessary for ground coil placement. One possible method of reducing this cost is to place the ground coils beneath the slab floor of the building. This configuration of ground coil placement has not been specifically addressed in previous research. Freezing of the soil must be avoided in such a system. To simulate the temperature response of the surrounding soil to heat pump operation, a computer model was developed which incorporates line source theory in the form of a system of rings. The fluid temperature change along the length of the coil was used to determine the distribution of the ground load throughout the ring system. The model includes an adiabatic upper boundary, seasonal soil temperature variation, and thermal interference throughout the system. Using these results, the minimum soil temperature over a season was predicted. Based on these results, design recommendations for ground coil installation are provided based on available area, soil type, heat extraction rate, depth of coil beneath the slab floor, and depth of slab floor below grade. These include recommendations for pipe spacing, flow direction, and a method to determine whether this type of system is feasible for installation in a particular location.

1.
ASHRAE, 1985, “ASHRAE Handbook of Fundamentals,” American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Atlanta, GA.
2.
Bose, J. E., Parker, J. D., and McQuiston, F. C., 1985, “Design/Data Manual for Closed-Loop Ground-Coupled Heat Pump Systems,” American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA.
3.
Bose, J. E., Adams, D., Price, E., and Weaver, B., 1988, “Closed-Loop/Ground-Source Heat Pump Systems, Installation Guide,” Oklahoma State University, International Ground Source Heat Pump Association, Stillwater, Oklahoma.
4.
Carslaw, H. S., and Jaeger, J. C., 1959, Conduction of Heat in Solids, Clarendon Press, Oxford.
5.
Collins, W. D., 1925, “Temperature of Water Available for Industrial Use in the United States,” U. S. Geological Survey Water Supply Paper 520-F, Washington; U. S. Geological Survey.
6.
Drown
D. C.
,
Kast
T. P.
, and
Den Braven
K. R.
, Feb.,
1992
, “
A Ground-Coupled Storage Heat Pump System with Waste Heat Recovery
,”
ASHRAE Journal
Atlanta, GA, Vol.
35
, pp.
20
24
.
7.
Hart, David P., and Couvillion, Rick, 1986, “Earth Coupled Heat Transfer,” National Water Well Association, Dublin OH.
8.
Ingersoll, L. R., Zobel, O. J., Ingersoll, A. C., 1954, “Theory of Earth Heat Exchangers,” Heat Conduction, University of Wisconsin Press, Madison WI.
9.
Kalman, M. D., March, 1980, “Earth Heat Exchangers for Ground Source Heat Pumps,” Master’s Thesis, Georgia Institute of Technology.
10.
Kast, T. P., Feb., 1989, “Design, Construction, and Instrumentation of the Idaho/Energy Conservation Technology House,” Master’s Thesis, University of Idaho.
11.
Kusuda
T.
, and
Achenbach
P. R.
,
1965
, “
Earth Temperature and Thermal Diffusivity at Selected Stations in the United States
,”
ASHRAE Transactions
, Vol.
71
, pt. 1, p.
61
61
.
12.
Mei, V. C., Dec., 1986, “Horizontal Ground-Coil Heat Exchanger Theoretical and Experimental Analysis,” ORNL/CON-193.
13.
Nielson, Eric, 1994, “Performance Prediction of a Sub-Slab Heat Exchanger for Ground-Coupled Heat Pumps,” Master’s thesis. University of Idaho.
This content is only available via PDF.
You do not currently have access to this content.