The thermal performance of a plate-type air collector was evaluated experimentally. Tests were performed at the two ASHRAE Standard 93-1986 recommended flowrates and at a variety of inlet gage pressures to cover the three possible cases of collector leakage (inward, outward, inward-outward). These tests show that the thermal performance of air collectors depends on flowrate and inlet gage pressure (or the associated leakage rate). If the collector is used at an inlet gage pressure near atmospheric pressure as is often the case in the no-storage type of systems, then it is recommended to test the collector at an inlet gage pressure of zero. For collectors operating at various inlet gage pressures it is suggested to test them at three inlet gage pressures. As for the test flowrate, the present work confirmed the results of other studies and emphasizes the need to test the collectors at the design flowrate. Three methods of thermal performance representation were used and compared: One method bases the efficiency on the inlet flowrate, another on the outlet flowrate, and the third involves an overall enthalpy balance. When plotted in the classic way, that is, η vs. (Ti − Ta)/G the three methods exhibit significant differences, especially for the inward leakage case. An uncertainty analysis on the data obtained for this study indicates that for the inward leakage case, unacceptable uncertainties occur at high values of (Ti − Ta)/G.
Skip Nav Destination
Article navigation
Research Papers
Thermal Performance Representation and Testing of Air Solar Collectors
M. A. Bernier,
M. A. Bernier
Building Services Section, Institute for Research in Construction, National Research Council Canada, Ottawa, Canada, K1A 0R6
Search for other works by this author on:
E. G. Plett
E. G. Plett
Mechanical and Aeronautical Eng. Dept., Carleton University, Ottawa, Canada, K1S 5B6
Search for other works by this author on:
M. A. Bernier
Building Services Section, Institute for Research in Construction, National Research Council Canada, Ottawa, Canada, K1A 0R6
E. G. Plett
Mechanical and Aeronautical Eng. Dept., Carleton University, Ottawa, Canada, K1S 5B6
J. Sol. Energy Eng. May 1988, 110(2): 74-81 (8 pages)
Published Online: May 1, 1988
Article history
Received:
July 1, 1987
Online:
November 11, 2009
Citation
Bernier, M. A., and Plett, E. G. (May 1, 1988). "Thermal Performance Representation and Testing of Air Solar Collectors." ASME. J. Sol. Energy Eng. May 1988; 110(2): 74–81. https://doi.org/10.1115/1.3268248
Download citation file:
Get Email Alerts
Cited By
Related Articles
Initial Analysis of PCM Integrated Solar Collectors
J. Sol. Energy Eng (May,2006)
Liquid Desiccant Air Conditioning Using Single Storage Solution Tank, Evaporative Cooling, and Marquise-Shaped Solar Collector
J. Energy Resour. Technol (November,2021)
Uncertainty Analysis of Solid-Liquid-Vapor Phase Change of a Metal Particle Subject to Nanosecond Laser Heating
J. Manuf. Sci. Eng (April,2013)
Develop Acceptance Criteria of Pressure Test of Buried Pipeline Using Uncertainty Analysis
J. Pressure Vessel Technol (February,2011)
Related Proceedings Papers
Related Chapters
Updates, Revisions and Corrections to this Book
Supplement to Fluid Mechanics, Water Hammer, Dynamic Stresses, and Piping Design
PSA Level 2 — NPP Ringhals 2 (PSAM-0156)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
Experimental Testing and Modeling of a Micro Solar Thermal Collector with Direct Absorption Nanofluids
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)