In this paper, the ultimate hoop strength of an industrial (±55 deg)9 filament-wound glass-reinforced epoxy (GRE) pipe as a short-term test is determined according to the ASTM D-1599 standard by performing the internal hydrostatic pressure test. After the test, the failure surface of the pipe is photographed by a high magnification camera, and in addition, the explanations are presented about the type of failure. The main purpose of this study is to compare the results obtained for the ultimate hoop strength and failure mechanisms of the pipe by using the internal hydrostatic pressure test with that by the split disk test method according to the ASTM D-2290 standard in the previous work.

References

1.
Martens
,
M.
, and
Ellyin
,
F.
,
2000
, “
Biaxial Monotonic Behavior of a Multidirectional Glass Fiber Epoxy Pipe
,”
Compos. Part A
,
31
(
9
), pp.
1001
1014
.
2.
Soden
,
P. D.
,
Kitching
,
R.
, and
TSE
,
P. C.
,
1989
, “
Experimental Failure Stresses for ±55 ° Filament Wound Glass Fibre Reinforced Plastic Tubes Under Biaxial Loads
,”
Composites
,
20
(
2
), pp.
125
135
.
3.
Rousseau
,
J.
,
Perreux
,
D.
, and
Verdiere
,
N.
,
1999
, “
The Influence of Winding Patterns on the Damage Behaviour of Filament-Wound Pipes
,”
Compos. Sci. Technol.
,
59
(
9
), pp.
1439
1449
.
4.
Xia
,
M.
,
Takayanagi
,
H.
, and
Kemmochi
,
K.
,
2001
, “
Analysis of Multi-Layered Filament-Wound Composite Pipes Under Internal Pressure
,”
Compos. Struct.
,
53
(
4
), pp.
483
491
.
5.
Tarakcioglu
,
N.
,
Akdemir
,
A.
, and
Avci
,
A.
,
2001
, “
Strength of Filament Wound GRP Pipes With Surface Crack
,”
Compos. Part B
,
32
(
2
), pp.
131
138
.
6.
Mertiny
,
P.
, and
Ellyin
,
F.
,
2002
, “
Influence of the Filament Winding Tension on Physical and Mechanical Properties of Reinforced Composites
,”
Compos. Part A
,
33
(
12
), pp.
1615
1622
.
7.
Naik
,
M. K.
,
2005
, “
The Effect of Environmental Conditions on the Hydrostatic Burst Pressure and Impact Performance of Glass Fiber Reinforced Thermoset Pipes
,” Master's thesis, King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia.
8.
Meijer
,
G.
, and
Ellyin
,
F.
,
2008
, “
A Failure Envelope for ±60 ° Filament Wound Glass Fibre Reinforced Epoxy Tubulars
,”
Compos. Part A
,
39
(
3
), pp.
555
–5
64
.
9.
Faria
,
H.
, and
Guedes
,
R. M.
,
2010
, “
Long-Term Behaviour of GFRP Pipes: Reducing the Prediction Test Duration
,”
Polym. Test.
,
29
(
3
), pp.
337
345
.
10.
Melo
,
J. D. Z.
,
Neto
,
F. L.
,
de Araujo Barros
,
G.
, and
de Almeida Mesquita
,
F. N.
,
2010
, “
Mechanical Behavior of GRP Pressure Pipes With Addition of Quartz Sand Filler
,”
J. Compos. Mater.
,
45
(
6
), pp.
717
726
.
11.
Martins
,
L. A. L.
,
Bastian
,
F. L.
, and
Netto
,
T. A.
,
2012
, “
Structural and Functional Failure Pressure of Filament Wound Composite Tubes
,”
Mater. Des.
,
36
(
4
), pp.
779
787
.
12.
Martins
,
L. A. L.
,
Bastian
,
F. L.
, and
Netto
,
T. A.
,
2013
, “
The Effect of Stress Ratio on the Fracture Morphology of Filament Wound Composite Tubes
,”
Mater. Des.
,
49
(
8
), pp.
471
484
.
13.
Rafiee
,
R.
,
2013
, “
Experimental and Theoretical Investigations on the Failure of Filament-Wound GRP Pipes
,”
Compos. Part B
,
45
(
1
), pp.
257
267
.
14.
Rafiee
,
R.
, and
Reshadi
,
F.
,
2014
, “
Simulation of Functional Failure in GRP Mortar Pipes
,”
Compos. Struct.
,
113
, pp.
155
163
.
15.
Rafiee
,
R.
, and
Amini
,
A.
,
2015
, “
Modeling and Experimental Evaluation of Functional Failure Pressures in Glass Fiber Reinforced Pipes
,”
Comput. Mater. Sci.
,
96
(
Part B
), pp.
579
588
.
16.
Rafiee
,
R.
,
Reshadi
,
F.
, and
Eidi
,
S.
,
2015
, “
Stochastic Analysis of Functional Failure Pressures in Glass Fiber Reinforced Polyester Pipes
,”
Mater. Des.
,
67
, pp.
422
427
.
17.
Mahdavi
,
H. R.
,
Rahimi
,
G. H.
, and
Farrokhabadi
,
A.
,
2016
, “
Failure Analysis of (±55°)9 Filament-Wound GRE Pipes Using Acoustic Emission Technique
,”
Eng. Fail. Anal.
,
62
, pp.
178
187
.
18.
ASTM International
,
2004
, “
Standard Test Method for Apparent Hoop Tensile Strength of Plastic or Reinforced Plastic Pipe by Split Disk Method
,” ASTM International, West Conshohocken, PA, Standard No.
ASTM D-2290-04
.
19.
ASTM International
,
1999
, “
Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings
,” ASTM International, West Conshohocken, PA, Standard No.
ASTM D-1599-99
.
20.
Hu
,
F. Z.
,
1997
, “
Fatigue of Glass Reinforced Epoxy Pipes and Joints for Offshore Applications
,” Ph.D. thesis, University of Newcastle, Newcastle, Australia.
You do not currently have access to this content.