In this paper, an extensometer was specifically designed for online deformation monitoring of high temperature pipes and its applicability was verified experimentally. The design procedure and the installation of the extensometer were described in detail. Experiments were carried out to prove the accuracy and the reliability of the extensometer. The laboratory test at room temperature was performed. The reliability of the extensometer at high temperature was validated by on-site monitoring of the deformation of a main steam pipe operating at 540 °C in a power plant. It was demonstrated that the designed extensometer has a high accuracy and an excellent reliability for measurement of the deformation of the high temperature pipes.

References

1.
Tu
,
S. T.
, “
Life Prediction and Monitoring of Critical Industrial Equipment
,”
Transferability and Applicability of Current Mechanics Approaches
, Eds
G. C.
Sih
,
S. T.
Tu
,
Z. D.
Wang
,
Shanghai: ECUST Press
2009, pp.
13
22
.
2.
Cane
,
B. J.
, 1982, “
Remaining Creep Life Estimation by Strain Assessment on Plant
,”
Int. J. Pressure Vessels Piping
,
10
(
1
), pp.
11
30
.
3.
Chen
,
L.
,
Jiang
,
J. L.
,
Fan
,
Z. C.
,
Chen
,
X. D.
, and
Yang
,
T. C.
,2007, “
A New Model for Life Prediction of Fatigue-Creep Interaction
,”
Int. J. Fatigue
,
29
(
4
), pp.
615
619
.
4.
Borodii
,
M. V.
, and
Adamchuk
,
M. P.
, 2009, “
Life Assessment for Metallic Materials With the Use of the Strain Criterion for Low-Cycle Fatigue
,”
Int. J. Fatigue
,
31
(
10
), pp.
1579
1587
.
5.
Mohanty
,
L.
, and
Kuang
,
K.
, 2011, “
Surface Structure Monitoring With Plastic Optical Fiber
,”
Opt. Lasers Eng.
,
49
(
7
), pp.
984
987
.
6.
Lin
,
Z. R.
, and
Kasai
,
A.
, 2011, “
Elastic Waves in Pipe Resting on Two-Parameter Foundation
,”
Adv. Struct.
,
163
, pp.
2857
2861
.
7.
Tu
,
S. T.
,
Gong
,
J. M.
,
Ling
,
X.
, and
He
,
X. Y.
, 2001, “
Long-Term Measurement of Local Creep Deformation by Optical Fiber Marking and Remote Monitoring
,”
ASTM Spec. Tech. Publ.
,
1402
, pp.
184
192
.
8.
Morris
,
A.
,
Dear
,
J.
, and
Kourmpetis
,
M.
, 2006, “
High Temperature Steam Pipelines Development of the ARCMAC Creep Monitoring System
,”
Strain
,
42
, pp.
181
185
.
9.
Morris
,
A.
,
Dear
,
J.
, and
Kourmpetis
,
M.
, 2007, “
Optical Strain Monitoring Techniques for Life Assessment of Components in Power Generation Plants
,”
Proc. Inst. Mech. Eng., Part A
,
221
, pp.
1141
1152
.
10.
Jia
,
J. H.
,
Hu
,
X. Y.
,
An
,
Z. L.
,
Xuan
,
F. Z.
, and
Tu
,
S. T.
, 2011, “
Design and Verification of a Sensing Device for Deformation Measurement of High Temperature Pipes
,”
ASME J. Pressure Vessel Technol.
,
133
(
4
), p.
041601
.
11.
Niu
,
X. C.
,
Gong
,
J. M.
,
Jiang
,
Y.
,
Geng
,
L. Y.
, and
Tu
,
S. T.
,2008, “
Finite Element Analysis on Creep Damage for Main Steam Pipelines in a Power Plant Based on Damage Mechanics
,”
Proc. Chin. Soc. Electr. Eng.
,
28
(
20
), pp.
32
37
.
12.
Viswanathan
,
R.
, 1989,
Damage Mechanisms and Life Assessment of High-Temperature Components
,
ASM International
,
Materials Park, OH
.
13.
Kouichi
,
M.
,
Hideaki
,
K.
, and
Takashi
,
W.
, 1990, “
Prediction of Long Term Creep Curve and Rupture Life of 2.25Cr-1Mo Steel
,”
Iron Steel Inst. Jpn. Int.
,
30
(
10
), pp.
817
822
.
You do not currently have access to this content.