In this paper, an extensometer was specifically designed for online deformation monitoring of high temperature pipes and its applicability was verified experimentally. The design procedure and the installation of the extensometer were described in detail. Experiments were carried out to prove the accuracy and the reliability of the extensometer. The laboratory test at room temperature was performed. The reliability of the extensometer at high temperature was validated by on-site monitoring of the deformation of a main steam pipe operating at 540 °C in a power plant. It was demonstrated that the designed extensometer has a high accuracy and an excellent reliability for measurement of the deformation of the high temperature pipes.
Issue Section:
Technical Briefs
Topics:
Deformation,
Design,
High temperature,
Pipes,
Reliability,
Temperature,
Steam,
Sensors,
Pipelines
References
1.
Tu
, S. T.
, “Life Prediction and Monitoring of Critical Industrial Equipment
,” Transferability and Applicability of Current Mechanics Approaches
, Eds G. C.
Sih
, S. T.
Tu
, Z. D.
Wang
, Shanghai: ECUST Press
2009, pp. 13
–22
.2.
Cane
, B. J.
, 1982, “Remaining Creep Life Estimation by Strain Assessment on Plant
,” Int. J. Pressure Vessels Piping
, 10
(1
), pp. 11
–30
.3.
Chen
, L.
, Jiang
, J. L.
, Fan
, Z. C.
, Chen
, X. D.
, and Yang
, T. C.
,2007, “A New Model for Life Prediction of Fatigue-Creep Interaction
,” Int. J. Fatigue
, 29
(4
), pp. 615
–619
.4.
Borodii
, M. V.
, and Adamchuk
, M. P.
, 2009, “Life Assessment for Metallic Materials With the Use of the Strain Criterion for Low-Cycle Fatigue
,” Int. J. Fatigue
, 31
(10
), pp. 1579
–1587
.5.
Mohanty
, L.
, and Kuang
, K.
, 2011, “Surface Structure Monitoring With Plastic Optical Fiber
,” Opt. Lasers Eng.
, 49
(7
), pp. 984
–987
.6.
Lin
, Z. R.
, and Kasai
, A.
, 2011, “Elastic Waves in Pipe Resting on Two-Parameter Foundation
,” Adv. Struct.
, 163
, pp. 2857
–2861
.7.
Tu
, S. T.
, Gong
, J. M.
, Ling
, X.
, and He
, X. Y.
, 2001, “Long-Term Measurement of Local Creep Deformation by Optical Fiber Marking and Remote Monitoring
,” ASTM Spec. Tech. Publ.
, 1402
, pp. 184
–192
.8.
Morris
, A.
, Dear
, J.
, and Kourmpetis
, M.
, 2006, “High Temperature Steam Pipelines Development of the ARCMAC Creep Monitoring System
,” Strain
, 42
, pp. 181
–185
.9.
Morris
, A.
, Dear
, J.
, and Kourmpetis
, M.
, 2007, “Optical Strain Monitoring Techniques for Life Assessment of Components in Power Generation Plants
,” Proc. Inst. Mech. Eng., Part A
, 221
, pp. 1141
–1152
.10.
Jia
, J. H.
, Hu
, X. Y.
, An
, Z. L.
, Xuan
, F. Z.
, and Tu
, S. T.
, 2011, “Design and Verification of a Sensing Device for Deformation Measurement of High Temperature Pipes
,” ASME J. Pressure Vessel Technol.
, 133
(4
), p. 041601
.11.
Niu
, X. C.
, Gong
, J. M.
, Jiang
, Y.
, Geng
, L. Y.
, and Tu
, S. T.
,2008, “Finite Element Analysis on Creep Damage for Main Steam Pipelines in a Power Plant Based on Damage Mechanics
,” Proc. Chin. Soc. Electr. Eng.
, 28
(20
), pp. 32
–37
.12.
Viswanathan
, R.
, 1989, Damage Mechanisms and Life Assessment of High-Temperature Components
, ASM International
, Materials Park, OH
.13.
Kouichi
, M.
, Hideaki
, K.
, and Takashi
, W.
, 1990, “Prediction of Long Term Creep Curve and Rupture Life of 2.25Cr-1Mo Steel
,” Iron Steel Inst. Jpn. Int.
, 30
(10
), pp. 817
–822
.Copyright © 2012
by American Society of Mechanical Engineers
You do not currently have access to this content.