Storage tanks are widely used in the industry to store hydrocarbon products. Corrosion damage is considered to be a serious threat to the structural integrity of the industrial storage tanks if it occurs on the primary pressure containment boundary. Therefore, fitness-for-service (FFS) assessment of these structures is performed periodically in order to ensure the operational safety and structural integrity. In this paper, evaluation methods are proposed for FFS assessment of storage tanks undergoing corrosion damage. The proposed methods are shown to give reasonably accurate and conservative assessment of the remaining strength factor. The methods are demonstrated through an example and the results are verified by inelastic finite element analysis.
Skip Nav Destination
e-mail: mosharraf.hossain@mun.ca
Article navigation
April 2010
Research Papers
Fitness-for-Service Assessment of Hydrocarbon Storage Tanks
F. Ahmad,
F. Ahmad
Faculty of Engineering and Applied Science,
Memorial University
, St. John’s, NL, A1B 3X5, Canada
Search for other works by this author on:
M. M. Hossain,
M. M. Hossain
Faculty of Engineering and Applied Science,
e-mail: mosharraf.hossain@mun.ca
Memorial University
, St. John’s, NL, A1B 3X5, Canada
Search for other works by this author on:
R. Seshadri
R. Seshadri
Faculty of Engineering and Applied Science,
Memorial University
, St. John’s, NL, A1B 3X5, Canada
Search for other works by this author on:
F. Ahmad
Faculty of Engineering and Applied Science,
Memorial University
, St. John’s, NL, A1B 3X5, Canada
M. M. Hossain
Faculty of Engineering and Applied Science,
Memorial University
, St. John’s, NL, A1B 3X5, Canadae-mail: mosharraf.hossain@mun.ca
R. Seshadri
Faculty of Engineering and Applied Science,
Memorial University
, St. John’s, NL, A1B 3X5, CanadaJ. Pressure Vessel Technol. Apr 2010, 132(2): 021207 (6 pages)
Published Online: March 31, 2010
Article history
Received:
March 27, 2009
Revised:
November 22, 2009
Online:
March 31, 2010
Published:
March 31, 2010
Citation
Ahmad, F., Hossain, M. M., and Seshadri, R. (March 31, 2010). "Fitness-for-Service Assessment of Hydrocarbon Storage Tanks." ASME. J. Pressure Vessel Technol. April 2010; 132(2): 021207. https://doi.org/10.1115/1.4000726
Download citation file:
Get Email Alerts
Cited By
Influence of water cover on the blast resistance of circular plates
J. Pressure Vessel Technol
Dynamic response and damage analysis of a large steel tank impacted by an explosive fragment
J. Pressure Vessel Technol
Surface Strain Measurement for Non-Intrusive Internal Pressure Evaluation of A Cannon
J. Pressure Vessel Technol
Related Articles
Corrosion Effects on Reliability of Flat Plates in Tension
J. Offshore Mech. Arct. Eng (May,2012)
Fitness-for-Service Evaluation of Thermal Hot Spots and Corrosion Damage in Cylindrical Pressure Components
J. Pressure Vessel Technol (October,2009)
Probabilistic Finite-Element Analysis of S2-Glass Epoxy Composite Beams for Damage Initiation Due to High-Velocity Impact
ASME J. Risk Uncertainty Part B (December,2016)
Validity of Assessment Procedure in p - M Method for Multiple Volumetric Flaws
J. Pressure Vessel Technol (April,2010)
Related Proceedings Papers
Related Chapters
Source Term Assessments in PSA Level 2 for the Outage Period (PSAM-0168)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
Analysis of Shutdown Mode at BarsebÄck 2; an Approach to a Combined PSA, HFA and Deterministic Analysis (PSAM-0117)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
Introduction
Computer Vision for Structural Dynamics and Health Monitoring