Abstract

Helical strakes can suppress vortex-induced vibrations (VIV) in pipelines spans as well as risers. Pure in-line (IL) VIV is more of a concern for pipelines than for risers. To make it possible to assess the effectiveness of partial strake coverage for this case, an important gap in the hydrodynamic data for strakes is filled by the reported IL forced vibration tests. Therein a strake-covered rigid cylinder undergoes harmonic purely IL motion while subject to a uniform “flow” created by towing the test rig along SINTEF Ocean's towing tank. These tests cover a range of frequencies and amplitudes of the harmonic motion, to generate added-mass and excitation functions are derived from the in-phase and 90° out-of-phase components of the hydrodynamic force on the pipe, respectively. Using these excitation- and added-mass functions in VIVANA together with those from experiments on bare pipe by Aronsen (2007), the IL VIV response of partially strake-covered pipeline spans is calculated. It is found that as little as 10% strake coverage at the optimal location effectively suppresses pure IL VIV.