Abstract

X-ray radiography has proved to be essential in medical imaging and examination of material structures because it is noninvasive and generates images based on well-understood attenuation characteristics of materials. For radiographs of multiple overlapping materials, unraveling the individual attenuation contributions poses a problem that is commonly handled by either taking many radiographs at different object orientations for computed tomography or multiple images with different photon energies for Multiple Energy X-ray Absorptiometry (MEXA). Alternatively, to perform faster measurements, a novel algorithm has been developed to determine multimaterial systems' density. The algorithm can be effectively applied to perform measurements using only one to four radiographs of the object. A case study has been presented for a layered cylindrical object that involved sensitivity studies on image noise, X-ray generator voltage fluctuations, layer thickness measurement perturbations, and X-ray generator photon energy distribution fluctuations using simulated radiographs and density calculations using actual radiographs. The results from the simulated and experimental results were found to agree with actual density values.

References

1.
Dinten, J., and Rebuffel, V.,
,
2006
, “
Dual-Energy X-Ray Imaging: Benefits and Limits
,”
9th European Conference on Non-Destructive Testing
,
Berlin, Germany
, Sept.,
2006
, Paper No. 3672.https://www.ndt.net/?id=3672
2.
Lehmann
,
L. A.
,
Alvarez
,
R. E.
,
Macovski
,
A.
,
Brody
,
W. R.
,
Pelc
,
N. J.
,
Riederer
,
S. J.
, and
Hall
,
A. L.
,
1981
, “
Generalized Image Combinations in Dual kVp Digital Radiography
,”
Med. Phys.
,
8
(
5
), pp.
659
667
.10.1118/1.595025
3.
Bolotin
,
H. H.
,
2001
, “
Inaccuracies Inherent in Dual-Energy X-Ray Absorptiometry In Vivo Bone Mineral Densitometry May Flaw Osteopenic/Osteoporotic Interpretations and Mislead Assessment of Antiresorptive Therapy Effectiveness
,”
Bone
,
28
(
5
), pp.
548
555
.10.1016/S8756-3282(01)00423-9
4.
Elbakri
,
I. A.
, and
Fessler
,
J. A.
,
2002
, “
Statistical Image Reconstruction for Polyenergetic X-Ray Computed Tomography
,”
IEEE Trans. Med. Imaging
,
21
(
2
), pp.
89
99
.10.1109/42.993128
5.
Doerry
,
A. W.
,
2007
, “
Computed Tomography–The Details
,” Sandia National Laboratories, Albuquerque, NM, Report No. SAND2007-4252.
6.
Piet, S. J., Bays, S. E.,and Soelberg, N.
,
2011
, “
HTGR Technology Family Assessment for a Range of Fuel Cycle Missions
,” accessed June 28, 2011, https://inldigitallibrary.inl.gov/sites/sti/sti/4731793.pdf
7.
International Atomic Energy Agency
,
1997
, Fuel Performance and Fission Product Behavior in Gas Cooled Reactors, Vienna,
International Atomic Energy Agency
,
Vienna, Austria
, accessed Feb. 14, 2022, https://www-pub.iaea.org/MTCD/Publications/PDF/te_978_prn.pdf
8.
Pacific Northwest National Laboratory
,
2004
, Innovative Approaches to Automating QA/QC of Fuel Particle Production Using on-Line Nondestructive Methods for Higher Reliability,
Pacific Northwest National Laboratory
,
Richland, WA
.
9.
Karl
,
V.
, and
Lee
,
Y. W.
,
2005
, “
Advances in HTGR Fuel Technology–A New IAEA Coordinated Research Program
,” International Congress on Advances in Nuclear Power Plants,
American Nuclear Society
,
Seoul, Korea
, May 15, pp.
274
282
.
10.
Anderson
,
J. M.
,
Jackson
,
A. D.
,
Martin
,
H. G.
, and
Schubert
,
J. G.
,
2011
, “
Nondestructive Evaluation of Naval Munitions Using X-Ray CT
,”
Res. Nondestruct. Eval.
,
22
(
1
), pp.
16
30
.10.1080/09349847.2010.517618
11.
Saravanan
,
T.
,
Philip
,
J.
,
Jayakumar
,
T.
, and
Raj
,
B.
,
2011
, “
Improved Estimation of Density of Boron Carbide Control Rods Using Digital X-Ray Radiography
,”
Insight: Non-Destr. Test. Condition Monit.
,
53
(
5
), pp.
258
262
.10.1784/insi.2011.53.5.258
12.
Poludniowski
,
G.
,
Landry
,
G.
,
Deblois
,
F.
,
Evans
,
P. M.
, and
Verhaegen
,
F.
,
2009
, “
SpekCalc: A Program to Calculate Photon Spectra From Tungsten Anode x-Ray Tubes
,”
Phys. Med. Biol.
,
54
(
19
), pp.
N433
N438
.10.1088/0031-9155/54/19/N01
13.
Berger
,
M. J.
,
Hubbell
,
J. H.
,
Seltzer
,
S. M.
,
Chang
,
J.
,
Coursey
,
J. S.
,
Sukumar
,
R.
,
Zucker
,
D. S.
, and
Olsen
,
K.
, XCOM: Photon Cross Sections Database,
NIST
,
Gaithersburg, MD,
accessed Dec. 15, 2010, http://www.nist.gov/pml/data/xcom/index.cfm
14.
Sinha
,
V.
,
Avachat
,
A.
, and
Lee
,
H. K.
,
2013
, “
Design and Development of a Neutron/X-Ray Combined Computed Tomography System at Missouri S&T
,”
J. Radioanal. Nucl. Chem.
,
296
(
2
), pp.
799
806
.10.1007/s10967-012-2062-x
15.
Sinha
,
V.
,
Srivastava
,
A.
,
Lee
,
H. K.
, and
Liu
,
X.
,
2014
, “
Performance Analysis of a Neutron and X-Ray Combined Computed Tomography System
,”
Nucl. Instrum. Methods Phys. Res. Sect. A
,
750
, pp.
12
18
.10.1016/j.nima.2014.03.004
16.
Sinha
,
V.
,
Srivastava
,
A.
, and
Lee
,
H. K.
,
2014
, “
A Novel Method for NDT Applications Using NXCT System at the Missouri University of Science & Technology
,”
Nucl. Instrum. Methods Phys. Res. Sect. A
,
750
, pp.
43
55
.10.1016/j.nima.2014.03.002
You do not currently have access to this content.