Abstract

This paper studies the transmission of elastic waves into test specimens for cylindrical waveguide-based ultrasonic transducers. However, to achieve better mode focusing, topographical waveguides with conical profiles were studied. Finite element simulations were used to study wave propagation and transmission into specimen samples using such “transmission horns.” Fundamental longitudinal mode L(0,1) was generated in cylindrical rods. Results from both finite element simulations and experiments show that a 50-deg conical transition profile help achieve better transmission and beam directionality into the specimen and also better reception of the back wall reflections at the waveguide as compared to a simple cylindrical rod waveguide.

References

1.
Antony Jacob
,
A.
,
Balasubramaniam
,
K.
,
Rajagopal
,
P.
,
Jeyaseelan
,
A.
,
Dutta
,
S.
,
Kumar
,
A.
,
Rao
,
B. P.
, and
Tammana
,
J.
,
2018
, “
Ultrasonic Transducers Based on Spray Coated PZT Film for In Situ Operation for Temperatures Up to 200 °C
,”
ISSS J. Micro Smart Syst.
,
7
(
1
), pp.
25
34
. 10.1007/s41683-018-0020-8
2.
Mcskimin
,
H. J.
,
1959
, “
Measurement of Ultrasonic Wave Velocities and Elastic Moduli for Small Solid Specimens at High Temperatures
,”
J. Acoust. Soc. Am.
,
31
(
3
), pp.
287
295
. 10.1121/1.1907714
3.
Papadakis
,
E. P.
,
1974
, “
Monitoring the Moduli of Polymers With Ultrasound
,”
J. Appl. Phys.
,
45
(
3
), pp.
1218
1222
. 10.1063/1.1663392
4.
Lynnworth
,
L. C.
,
Liu
,
Y.
, and
Umina
,
J. A.
,
2005
, “
Extensional Bundle Waveguide Techniques for Measuring Flow of Hot Fluids
,”
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
,
52
(
4
), pp.
538
543
. 10.1109/TUFFC.2005.1428034
5.
Jen
,
C. K.
,
Legoux
,
J. G.
, and
Parent
,
L.
,
2000
, “
Experimental Evaluation of Clad Metallic Buffer Rods for High Temperature Ultrasonic Measurements
,”
NDT&E Int.
,
33
(
3
), pp.
145
153
. 10.1016/S0963-8695(99)00042-0
6.
Cegla
,
F. B.
,
Cawley
,
P.
,
Allin
,
J.
, and
Davies
,
J.
,
2011
, “
High-Temperature (>l500 °C) Wall Thickness Monitoring Using Dry-Coupled Ultrasonic Waveguide Transducers
,”
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
,
58
(
1
), pp.
156
167
. 10.1109/TUFFC.2011.1782
7.
Kwon
,
Y. E.
,
Jeon
,
H. J.
,
Kim
,
H. W.
, and
Kim
,
Y. Y.
,
2014
, “
Waveguide Tapering for Beam-Width Control in a Waveguide Transducer
,”
Ultrasonics
,
54
(
3
), pp.
953
960
. 10.1016/j.ultras.2013.11.006
8.
Murayama
,
R.
,
Kobayashi
,
M.
,
Matsumoto
,
K.
, and
Kobayashi
,
M.
,
2014
, “
Ultrasonic Inspection System Using a Long Waveguide with an Acoustic Horn for High-Temperature Structure
,”
J. Sens. Technol.
,
4
(
4
), pp.
177
185
. 10.4236/jst.2014.44017
9.
Nicholson
,
N. C.
, and
McDicken
,
W. N.
,
1996
, “
A Comparison of Coupling Horns for Waveguides Used in Medical Ultrasonics
,”
Ultrasonics
,
34
(
7
), pp.
747
755
. 10.1016/0041-624X(96)80002-B
10.
Verma
,
B.
,
Mishra
,
T. K.
,
Balasubramaniam
,
K.
, and
Rajagopal
,
P.
,
2014
, “
Interaction of Low-Frequency Axisymmetric Ultrasonic Guided Waves With Bends in Pipes of Arbitrary Bend Angle and General Bend Radius
,”
Ultrasonics
,
54
(
3
), pp.
801
808
. 10.1016/j.ultras.2013.10.007
11.
Ashish
,
A. J.
,
Rajagopal
,
P.
,
Balasubramaniam
,
K.
,
Kumar
,
A.
,
Rao
,
B. P.
, and
Jayakumar
,
T.
,
2017
, “
Bulk Ultrasonic NDE of Metallic Components at High Temperature Using Magnetostrictive Transducers
,”
AIP Conf. Proc.
,
1806
(
1
), p.
050010
. 10.1063/1.4974604
12.
Jacob
,
A. A.
,
Rajagopal
,
P.
, and
Balasubramaniam
,
K.
,
2018
, “
Selective Modal Excitation for Optimization of Waveguide Based Bulk Ultrasonic Transducers Selective Modal Excitation for Optimization of Waveguide Based Bulk Ultrasonic Transducers Selective Modal Excitation for Optimization of Waveguide Based Bulk Ultra
,”
NDT&E Int.
,
94
, pp.
47
55
. 10.1016/j.ndteint.2017.11.005
13.
Dassault Systèmes Simulia Corporation
,
2014
,
ABAQUS
.
14.
Amireddy
,
K. K.
,
Balasubramaniam
,
K.
, and
Rajagopal
,
P.
,
2017
, “
Deep Subwavelength Ultrasonic Imaging Using Optimized Holey Structured Metamaterials
,”
Sci. Rep.
,
7
(
7777
), pp.
1
8
.
15.
Panda
,
R. S.
,
Rajagopal
,
P.
, and
Balasubramaniam
,
K.
,
2017
, “
Characterization of Delamination-Type Damages in Composite Laminates Using Guided Wave Visualization and Air-Coupled Ultrasound
,”
Struct. Heal. Monit.
,
16
(
2
), pp.
142
152
. 10.1177/1475921716666411
16.
Pattanayak
,
R. K.
,
Manogharan
,
P.
,
Balasubramaniam
,
K.
, and
Rajagopal
,
P.
,
2015
, “
Low Frequency Axisymmetric Longitudinal Guided Waves in Eccentric Annular Cylinders
,”
J. Acoust. Soc. Am.
,
137
(
6
), pp.
3253
3262
. 10.1121/1.4921269
17.
Pavlakovic
,
B.
,
Lowe
,
M.
,
Alleyne
,
O.
, and
Cawley
,
P.
,
1997
,
Disperse: A General Purpose Program for Creating Dispersion Curves
,
Springer
,
Boston, MA
, pp.
185
192
.
18.
Miller
,
G. F.
,
Pursey
,
H.
, and
Bullard
,
E. C.
,
1955
, “
On the Partition of Energy Between Elastic Waves in a Semi-Infinite Solid
,”
Proc. R. Soc. A
,
233
(
1192
), pp.
55
69
.
19.
Cegla
,
F. B.
,
2006
, “
Ultrasonic Waveguide Sensors for Fluid Characterisation and Remote Sensing
,”
Imperial College
London
.
You do not currently have access to this content.