Piezoresistive actuation of a microcantilever induced by biomolecular binding such as DNA hybridization and antibody-antigen binding is an important principle useful in biosensing applications. As the magnitude of the forces exerted is small, increasing the sensitivity of the microcantilever becomes critical. In this paper, we are considering to achieve this by geometric variation in the cantilever. The sensitivity of the cantilever was improved so that the device can sense the presence of antigen even if the magnitude of surface-stresses over the microcantilever was very small. We consider a “T-shaped” cantilever that eliminates the disadvantages while improving the sensitivity simultaneously. Simulations for validation have been performed using INTELLISUITE software (a micro-electromechanical system design and simulation package). The simulations reveal that the T-shaped microcantilever is almost as sensitive as a thin cantilever and has relatively very low buckling effect. Simulations also reveal that with an increase in thickness of the cantilever, there is a proportional decrease in the sensitivity.

1.
Wu
,
A. H. B.
,
Feng
,
Y. J.
,
Contois
,
J. H.
, and
Pervaiz
,
J.
, 1996, “
Comparison of Myoglobin, Creatine Kinase MB, and Cardiac Troponin I for Diagnosis of Acute Myocardial Infarction
,”
Ann. Clin. Lab Sci.
0091-7370,
26
, pp.
291
300
.
2.
Fletcher
,
P. C.
,
Xu
,
Y.
,
Gopinath
,
P.
,
Williams
,
J.
,
Alphenaar
,
B. W.
,
Bradshaw
,
R. D.
, and
Keynton
,
R. S.
, 2008, “
Piezoresistive Geometry for Maximizing Microcantilever Array Sensitivity
,”
UGIM 2008 17th Biennial University/Government/Industry Micro/Nano Symposium
, Jul. 13–16, pp.
208
211
.
3.
Pijanowska
,
D. G.
,
Sprenkels
,
A. J.
,
Olthuis
,
W.
, and
Bergveld
,
P.
, 2003, “
A Flow-Through Amperometric Sensor for Micro-Analytical Systems
,”
Sens. Actuators B
0925-4005,
91
(
1–3
), pp.
98
102
.
4.
Zhou
,
W.
,
Khaliq
,
A.
,
Tang
,
Y.
,
Ji
,
H.-F.
,
Selmic
,
R. R.
, 2005, “
Simulation and Design of Piezoelectric Microcantilever Chemical Sensors
,”
Sens. Actuators, A
0924-4247,
125
(
1
), pp.
69
75
5.
Tang
,
Y.
,
Fang
,
J.
,
Yan
,
X.
, and
Ji
,
H. -F.
, 2004, “
Fabrication and Characterization of SiO2 Microcantilever for Microsensor Application
,”
Sens. Actuators B
0925-4005,
97
(
1
), pp.
109
113
.
6.
Wu
,
A.
, ed., 1998, “
A Review on Cardiac Markers
,”
American Association of Clinical Chemistry (AACC)
,
Washington, DC
.
7.
Alansari
,
S. E.
, and
Croal
,
B. L.
, 2004, “
Diagnostic Value of Heart Fatty Acid-Binding Protein and Myoglobin in Patients Admitted With Chest Pain
,”
Ann. Clin. Biochem.
0004-5632,
41
, pp.
391
396
.
You do not currently have access to this content.