Skip Nav Destination
Issues
June 2016
ISSN 1932-6181
EISSN 1932-619X
Editorial
Introduction
J. Med. Devices. June 2016, 10(2): 020201.
doi: https://doi.org/10.1115/1.4033281
Topics:
Medical devices
Special Section Technical Briefs
Evaluation of Premium Ultrasound Systems With Sonographers: How Comparative Usability Testing Can Reveal Human Factors Issues Prior to Errors in the Exam Room
J. Med. Devices. June 2016, 10(2): 020901.
doi: https://doi.org/10.1115/1.4033167
Topics:
Errors
,
Testing
,
Ultrasound
,
Human factors
Biomechanical Comparison of Human and Swine Cardiovascular Tissues
J. Med. Devices. June 2016, 10(2): 020902.
doi: https://doi.org/10.1115/1.4033114
Topics:
Aorta
,
Biological tissues
,
Biomechanics
,
Cardiovascular system
A Muscle-Powered Counterpulsation Device for Tether-Free Cardiac Support: Form and Function
J. Med. Devices. June 2016, 10(2): 020903.
doi: https://doi.org/10.1115/1.4033115
Thrombogenicity Testing for Blood-Contacting Medical Devices in an In Vitro Ovine Blood-Loop
J. Med. Devices. June 2016, 10(2): 020904.
doi: https://doi.org/10.1115/1.4033116
Topics:
Blood
,
Medical devices
,
Testing
,
Thrombosis
,
Catheters
Peritoneal Membrane Oxygenation Therapy for Rats With Acute Respiratory Distress Syndrome
Nathan Legband, Liana Hatoum, Alec Thomas, Craig Kreikemeier-Bower, Douglas Hostetler, Keely Buesing, Mark Borden, Benjamin Terry
J. Med. Devices. June 2016, 10(2): 020905.
doi: https://doi.org/10.1115/1.4033201
Topics:
Lung
,
Membranes
,
Patient treatment
,
Oxygen
Torsional Ventricular-Assist Device: Design Considerations and Prototype Development
J. Med. Devices. June 2016, 10(2): 020906.
doi: https://doi.org/10.1115/1.4033117
Topics:
Actuators
,
Design
,
Engineering prototypes
Identifying Biomarkers for Intracranial Pressure Changes in the Development of a Noninvasive Monitoring Device
J. Med. Devices. June 2016, 10(2): 020907.
doi: https://doi.org/10.1115/1.4033202
Topics:
Pressure
Design and Development of a Rat Peritoneal Infusion Device for Oxygen Microbubble Bolus Delivery
Liana Hatoum, Nathan Legband, Alec Thomas, Craig Kreikemeier-Bower, Douglas Hostetler, Mark Borden, Keely Buesing, Benjamin Terry
J. Med. Devices. June 2016, 10(2): 020908.
doi: https://doi.org/10.1115/1.4033203
Topics:
Carbon dioxide
,
Cavities
,
Design
,
Oxygen
,
Pressure
Development of a Novel Positive Control for the Standard Test Method for the Platelet Leukocyte Assay: An In Vitro Hemocompatibility Assessment of Blood-Contacting Medical Devices
J. Med. Devices. June 2016, 10(2): 020909.
doi: https://doi.org/10.1115/1.4033118
Topics:
Blood
,
Leukocytes
,
Medical devices
,
Platelets
,
Blanks
A D-Shaped Bileaflet Bioprosthesis Which Replicates Physiological Left Ventricular Flow Patterns
J. Med. Devices. June 2016, 10(2): 020910.
doi: https://doi.org/10.1115/1.4033119
Topics:
Flow (Dynamics)
,
Physiology
,
Valves
,
Particulate matter
A Resectoscope for Robot-Assisted Transurethral Surgery
J. Med. Devices. June 2016, 10(2): 020911.
doi: https://doi.org/10.1115/1.4033153
Topics:
Robots
,
Surgery
,
Endoscopes
,
Visualization
Measurement of the Range of Motion of Laparoscopic Instruments Based on an Optical Tracking System
J. Med. Devices. June 2016, 10(2): 020912.
doi: https://doi.org/10.1115/1.4033168
Topics:
Instrumentation
,
Laparoscopic devices
,
Shapes
Evaluating Accuracy of Digital Thermometers Using a Tissue Phantom Mimicking Normal and Fever Environments
J. Med. Devices. June 2016, 10(2): 020913.
doi: https://doi.org/10.1115/1.4033204
Topics:
Biological tissues
,
Phantoms
,
Temperature
,
Thermometers
Low-Cost Three-Dimensional Printed Surgical Drill-Guiding Device for MPFL Reconstruction (Pat-Rig)
J. Med. Devices. June 2016, 10(2): 020914.
doi: https://doi.org/10.1115/1.4033205
Topics:
Drills (Tools)
,
Surgery
An Ultrasound Trainer for Astronauts
J. Med. Devices. June 2016, 10(2): 020915.
doi: https://doi.org/10.1115/1.4033206
Topics:
Astronauts
,
Feedback
,
Ultrasound
,
Stress
A Motion Tracking and Inertial Measurement Unit–Distance Sensor Fusion Module for Medical Simulation
J. Med. Devices. June 2016, 10(2): 020916.
doi: https://doi.org/10.1115/1.4033207
X-Ray Beam-Width Limiting Device
J. Med. Devices. June 2016, 10(2): 020917.
doi: https://doi.org/10.1115/1.4033208
Tandem Delivery Platform for Small Molecules and Biologic Pharmaceuticals Via Silicone Foam
J. Med. Devices. June 2016, 10(2): 020918.
doi: https://doi.org/10.1115/1.4033218
Development of Foot Temperature Measuring Device for Diabetes
J. Med. Devices. June 2016, 10(2): 020919.
doi: https://doi.org/10.1115/1.4033219
Topics:
Diabetes
,
Temperature
,
Sensors
Gait State Estimation for a Powered Ankle Orthosis Using Modified Fractional Timing and Artificialc Neural Network
J. Med. Devices. June 2016, 10(2): 020920.
doi: https://doi.org/10.1115/1.4033220
Topics:
Artificial neural networks
,
Orthotics
,
State estimation
,
Errors
,
Sensors
Development of a Force Sensor Prototype for Medical Devices
J. Med. Devices. June 2016, 10(2): 020921.
doi: https://doi.org/10.1115/1.4033221
Topics:
Engineering prototypes
,
Force sensors
,
Sensors
,
Medical devices
Unobtrusive Monitoring Respiration During Sedentary Behavior Using a Pressure Sensing Mat
J. Med. Devices. June 2016, 10(2): 020922.
doi: https://doi.org/10.1115/1.4033222
Topics:
Pressure
,
Sensors
,
Signal processing
Design and Thermal Testing of an Automatic Drill Guide for Less Invasive Cochlear Implantation
J. Med. Devices. June 2016, 10(2): 020923.
doi: https://doi.org/10.1115/1.4033223
Topics:
Design
,
Drills (Tools)
,
Testing
,
Drilling
,
Surgery
,
Bone
,
Trajectories (Physics)
An Ultraportable Device Platform for Aseptic Surgery in Field Settings
J. Med. Devices. June 2016, 10(2): 020924.
doi: https://doi.org/10.1115/1.4033224
Topics:
Air flow
,
Particulate matter
,
Surgery
,
Gates (Closures)
,
Design
Tissue Necrosis Associated With Chemical Ablations
J. Med. Devices. June 2016, 10(2): 020925.
doi: https://doi.org/10.1115/1.4033120
Effects of Tensile Stress on the Corrosion Rate of Magnesium
J. Med. Devices. June 2016, 10(2): 020926.
doi: https://doi.org/10.1115/1.4033121
Topics:
Corrosion
,
Magnesium (Metal)
,
Tension
Undergraduate Research in Assistive Technology: Design and Development of a Preventive Weight Shifting App to Reduce the Risk of Pressure Ulcers in Wheelchair Bound Patients With Spinal Cord Injuries (Phase 1)
J. Med. Devices. June 2016, 10(2): 020927.
doi: https://doi.org/10.1115/1.4033277
Topics:
Design
,
Pressure
,
Risk
,
Spinal cord
,
Undergraduate research
,
Weight (Mass)
,
Wheelchairs
,
Wounds
Fusion of Electrocardiogram and Accelerocardiogram Derived Respiration Methods for Estimation of Respiratory Phases
J. Med. Devices. June 2016, 10(2): 020928.
doi: https://doi.org/10.1115/1.4033122
Topics:
Signals
,
Signal processing
,
Data acquisition
Three-Dimensional Printed Patient Specific Ptosis Crutches as a Nonsurgical Solution for Elevating Upper Eyelids in Myasthenia Gravis Patients
J. Med. Devices. June 2016, 10(2): 020929.
doi: https://doi.org/10.1115/1.4033225
Topics:
Design
,
Design methodology
,
Glass
,
Muscle
,
Computer-aided design
A Single-Incision Delivery Tool for Epicardial Pacing and Defibrillation
J. Med. Devices. June 2016, 10(2): 020930.
doi: https://doi.org/10.1115/1.4033123
Topics:
Design
,
Endoscopes
,
Needles
,
Surgery
,
Visualization
,
Workflow
,
Wire
,
Pacemakers
,
Risk
,
Testing
Affective Voice Recognition of Older Adults
J. Med. Devices. June 2016, 10(2): 020931.
doi: https://doi.org/10.1115/1.4033226
Topics:
Robots
,
Human-robot interaction
,
Signals
,
Support vector machines
Causal Cardio-Postural Interaction Under Orthostatic Stress
J. Med. Devices. June 2016, 10(2): 020932.
doi: https://doi.org/10.1115/1.4033127
Topics:
Cardiovascular system
,
Data collection
,
Electromyography
,
Signals
,
Stress
,
Muscle
,
Blood
Continuous Balance Assessment of Autonomic Nervous System Using Time-Varying Analysis of Heart Rate Variability
J. Med. Devices. June 2016, 10(2): 020933.
doi: https://doi.org/10.1115/1.4033144
Topics:
Algorithms
,
Data collection
,
Nervous system
,
Signals
Biochip for Single Cell Analysis Using Laser Microfabrication
J. Med. Devices. June 2016, 10(2): 020934.
doi: https://doi.org/10.1115/1.4033166
Topics:
Lasers
,
Manufacturing
,
Microfabrication
,
Microfluidics
,
Polymers
,
Chemical etching
,
Annealing
,
Fluids
,
Transparency
,
Fracture (Materials)
Light-Emitting Diode Based Hand-Held Fluorescence Detector for Quantification of Pyranine
J. Med. Devices. June 2016, 10(2): 020935.
doi: https://doi.org/10.1115/1.4033227
Topics:
Fluorescence
,
Light-emitting diodes
,
Sensors
Motion Artifact Reduction Algorithm in Wearable Healthcare System
J. Med. Devices. June 2016, 10(2): 020936.
doi: https://doi.org/10.1115/1.4033169
Topics:
Algorithms
,
Health systems
,
Signals
Development of a Chronic Wound Healing Device
Vighneswara Siva Santosh Kumar Kondeti, Chi Phan, Alexandria Schauer, Jennifer Granick, Ryan C. Hunter, Peter J. Bruggeman
J. Med. Devices. June 2016, 10(2): 020937.
doi: https://doi.org/10.1115/1.4033240
Topics:
Bacteria
,
Plasmas (Ionized gases)
,
Wounds
,
Oxygen
Transcutaneous Energy Transfer and Inductive Communications for Ventricular-Assist Device Systems
J. Med. Devices. June 2016, 10(2): 020938.
doi: https://doi.org/10.1115/1.4033145
Topics:
Cycles
,
Electronics
,
Energy transformation
,
Signals
,
Stress
Effects of Ready-to-Wear Sizing Conventions on Sensor Placement for Medical Wearable Sensing
J. Med. Devices. June 2016, 10(2): 020939.
doi: https://doi.org/10.1115/1.4033170
Topics:
ASTM International
,
Biomedicine
,
Dimensions
,
Electrodes
,
Sensor placement
,
Wear
A New Test Rig for Human Joint and Prosthesis Characterization
J. Med. Devices. June 2016, 10(2): 020940.
doi: https://doi.org/10.1115/1.4033241
Topics:
Gates (Closures)
,
Prostheses
,
Stress
Design of a Dynamic Additive Manufacturing System for Use on Free-Moving Human Anatomy
J. Med. Devices. June 2016, 10(2): 020941.
doi: https://doi.org/10.1115/1.4033171
Topics:
Additive manufacturing
,
Body systems and structures
,
Design
,
Motors
In Vitro Assessment of Arterial Compliance of Calcified Regions After Orbital Atherectomy Using Optical Coherence Tomography
J. Med. Devices. June 2016, 10(2): 020942.
doi: https://doi.org/10.1115/1.4033146
Topics:
Coherence (Optics)
,
Pressure
A Device for Enabling Placement of Intra-Osseous Infusion Tools
J. Med. Devices. June 2016, 10(2): 020943.
doi: https://doi.org/10.1115/1.4033172
Topics:
Design
,
Needles
,
Drills (Tools)
A Pictorial Guide for Enabling Placement of Intra-Osseous Infusion Tools
J. Med. Devices. June 2016, 10(2): 020944.
doi: https://doi.org/10.1115/1.4033173
Topics:
Design
,
Drills (Tools)
Follow-the-Leader Deployment of Steerable Needles Using a Magnetic Resonance-Compatible Robot With Stepper Actuators
J. Med. Devices. June 2016, 10(2): 020945.
doi: https://doi.org/10.1115/1.4033242
Topics:
Actuators
,
Needles
,
Resonance
,
Robots
,
Wafer steppers
,
Trajectories (Physics)
Acute Perforation Properties of the Right Atrial Appendage
J. Med. Devices. June 2016, 10(2): 020946.
doi: https://doi.org/10.1115/1.4033147
Topics:
Biological tissues
,
Muscle
,
Biomechanics
,
Roofs
Noninvasive Postmarket Security Monitoring for Medical Devices
J. Med. Devices. June 2016, 10(2): 020947.
doi: https://doi.org/10.1115/1.4033285
Novel Multiscale Frequency Approach to Identify the Pivot Point of the Rotor
Shivaram Poigai Arunachalam, Elizabeth M. Annoni, Siva K. Mulpuru, Paul A. Friedman, Elena G. Tolkacheva
J. Med. Devices. June 2016, 10(2): 020948.
doi: https://doi.org/10.1115/1.4033148
Topics:
Rotors
Characterization of Focal Location During High-Intensity Focused Ultrasound Ablation in a Tissue Phantom Using Remote Thermocouple Arrays
Surendra Devarakonda, Seyed Ahmad Reza Dibaji, Prasanna Hariharan, Matthew R. Myers, Rupak K. Banerjee
J. Med. Devices. June 2016, 10(2): 020949.
doi: https://doi.org/10.1115/1.4033243
Magnetic Resonance Imaging Compatible Pneumatic Stepper Motor With Geneva Drive
J. Med. Devices. June 2016, 10(2): 020950.
doi: https://doi.org/10.1115/1.4033244
Topics:
Magnetic resonance imaging
,
Motors
,
Stepper motors
,
Stress
,
Rotation
,
Torque
,
Switches
,
Cylinders
The PhysioCam: Cardiac Pulse, Continuously Monitored by a Color Video Camera
J. Med. Devices. June 2016, 10(2): 020951.
doi: https://doi.org/10.1115/1.4033245
Topics:
Signals
,
Video cameras
,
Skin
,
Physiology
,
Sensors
,
Algorithms
A Disposable Robot for Intracerebral Hemorrhage Removal
J. Med. Devices. June 2016, 10(2): 020952.
doi: https://doi.org/10.1115/1.4033246
Topics:
Robots
,
Railroad passenger cars
,
Motors
Wearable Coplanar Capacitive Sensor for Measurement of Water Content—A Preliminary Endeavor
J. Med. Devices. June 2016, 10(2): 020953.
doi: https://doi.org/10.1115/1.4033149
Topics:
Sensors
,
Water
,
Biological tissues
,
Design
Design and Modeling of a Passive Hydraulic Device for Muscle Spasticity Simulation
J. Med. Devices. June 2016, 10(2): 020954.
doi: https://doi.org/10.1115/1.4033247
Topics:
Design
,
Flow (Dynamics)
,
Modeling
,
Muscle
,
Pistons
,
Simulation
,
Fluids
,
Cylinders
Tracheal Cartilage Ring Biomechanical Properties for Pediatric Exostent Design
J. Med. Devices. June 2016, 10(2): 020955.
doi: https://doi.org/10.1115/1.4033248
Topics:
Biomechanics
,
Cartilage
,
Compression
,
Design
,
Pediatrics
,
Relaxation (Physics)
,
Stiffness
,
Stress
,
Tension
,
Trachea
In Vitro Evaluations of Cardiac Mapping Catheters Designs and Utilities: Employing Visible Heart® Methodologies
J. Med. Devices. June 2016, 10(2): 020956.
doi: https://doi.org/10.1115/1.4033150
Topics:
Catheters
,
Public utilities
Intracardiac Magnetic Resonance Imaging Catheter With Origami Deployable Mechanisms
J. Med. Devices. June 2016, 10(2): 020957.
doi: https://doi.org/10.1115/1.4033151
Topics:
Catheters
,
Imaging
,
Magnetic resonance imaging
,
Manufacturing
,
Electronics
Smartphone-Enabled Flow-Monitoring Device for Peripheral Artery Disease
Kevin J. Wu, T. Stan Gregory, Charles Reader, Bobby Leitmann, Augustus Huffines, Sheila Donovan, Luke Mosteller, Jonathan R. Murrow, Zion Tsz Ho Tse
J. Med. Devices. June 2016, 10(2): 020958.
doi: https://doi.org/10.1115/1.4033152
Pneumatic Sleeve Orthosis for Lofstrand Crutches: Application of Soft Pneumatic FREE Actuator
J. Med. Devices. June 2016, 10(2): 020959.
doi: https://doi.org/10.1115/1.4033249
A Simplified Model for the Assessment of Ex Vivo Lung Perfusion Methodologies and Treatments
Lars Mattison, John Spratt, Brian Howard, Shancy Augustine, Semal Musleh, Gabriel Loor, Paul A. Iaizzo
J. Med. Devices. June 2016, 10(2): 020960.
doi: https://doi.org/10.1115/1.4033276
Topics:
Lung
A Novel Phantom Tissue Model for Skin Elasticity Quantification
J. Med. Devices. June 2016, 10(2): 020961.
doi: https://doi.org/10.1115/1.4033278
Topics:
Biological tissues
,
Elasticity
,
Phantoms
,
Skin
,
Stiffness
Thematic Framing: Creating Healthcare Innovations
J. Med. Devices. June 2016, 10(2): 020962.
doi: https://doi.org/10.1115/1.4033199
Topics:
Design
,
Framing (Construction)
,
Health care
,
Structural frames
,
Biomedicine
,
Cancer
A Device to Aid in Quantifying Lung Compliance and Edema
J. Med. Devices. June 2016, 10(2): 020963.
doi: https://doi.org/10.1115/1.4033284
Topics:
Lung
Application of Sociometers in the Emergency Department
Renaldo Blocker, Denny Yu, Hunter Hawthorne, Mustafa Sir, Thomas Hellmich, Susan Hallbeck, David Nestler, Kalyan Pasupathy
J. Med. Devices. June 2016, 10(2): 020964.
doi: https://doi.org/10.1115/1.4033287
Topics:
Emergencies
,
Computers
,
Sensors
Failure Mode Analysis and Design Optimization of a Nitinol Framed Hernia Repair Device
J. Med. Devices. June 2016, 10(2): 020965.
doi: https://doi.org/10.1115/1.4033286
Topics:
Design
,
Failure mechanisms
,
Maintenance
,
Nickel titanium alloys
,
Optimization
Design and Analysis of a Sensor-Enabled In-Ear Device for Physiological Monitoring
J. Med. Devices. June 2016, 10(2): 020966.
doi: https://doi.org/10.1115/1.4033200
Topics:
Ear
,
Physiology
,
Sensors
,
Temperature
,
Design
Improvement of Mobile Device Connectable Bioelectrical Impedance Analyzer
J. Med. Devices. June 2016, 10(2): 020967.
doi: https://doi.org/10.1115/1.4033288
Topics:
Batteries
,
Computer software
,
Electrodes
,
Errors
,
Health care
,
Reliability
,
Weight (Mass)
,
Shapes
,
Aluminum
,
Accuracy and precision
Research Papers
A Computational Approximation to Model Variation in Cancellous Bone Screw Pull-Out
J. Med. Devices. June 2016, 10(2): 021001.
doi: https://doi.org/10.1115/1.4032868
Topics:
Bone
,
Screws
,
Surgical screws
,
Stiffness
,
Geometry
Development of a Variable Stiffness Over Tube Based on Low-Melting-Point-Alloy for Endoscopic Surgery
J. Med. Devices. June 2016, 10(2): 021002.
doi: https://doi.org/10.1115/1.4032813
Topics:
Stiffness
,
Surgery
,
Endoscopic devices
Technical Brief
Design and Development of a Wheel Chair Based Manual Self-Transfer Device for Elderly and Disabled
J. Med. Devices. June 2016, 10(2): 024501.
doi: https://doi.org/10.1115/1.4032867
Device for Verifying the Patellar Cut During Knee Replacement Surgery
Erica L. Rex, Emmanuel M. Illical, Cinzia Gaudelli, Barry Wylant, Karen C. T. Ho, John G. Person, Carolyn Anglin
J. Med. Devices. June 2016, 10(2): 024502.
doi: https://doi.org/10.1115/1.4032870
Topics:
Bone
,
Design
,
Knee joint prostheses
,
Surgery
,
Testing
,
Computerized tomography
Analysis and Evaluation of a Robotic Trephination in Penetrating Keratoplasty
J. Med. Devices. June 2016, 10(2): 024503.
doi: https://doi.org/10.1115/1.4032869
Design Innovation Paper
A Robotic Ankle–Foot Prosthesis With Active Alignment
J. Med. Devices. June 2016, 10(2): 025001.
doi: https://doi.org/10.1115/1.4032866
Topics:
Prostheses
,
Robotics
,
Sensors
Email alerts
RSS Feeds
A Portable Aspiration-Assisted Device for End-Cut Prostate Biopsy of Large Tissue Sample
J. Med. Devices (June 2025)
Paper errata statement
J. Med. Devices