Purpose: Liver tolerance to multiple doses of Y90-microspheres is not known. Many patients (pts) are surviving long enough to be considered for a second and third liver treatments with internal radiation. Materials and Methods: The experience of a single center treating liver tumors with resin Y90-microspheres. Pts that received liver radiation prior to or after resin microsphere therapy were studied. Endpoints were toxicity, tumor response, shunting to lung, and effects on liver volume and function. The delivery activity of microspheres selected was not reduced below BSA dose calculation for patients without prior treatment. All patients received bilobar single session delivery. Results: A total of 38 pts; 14 women, 24 men, treated 6∕2003 to 9∕2006, with 33 pts receiving 2 courses and 5 pts with 3 courses of liver radiation. Retreatment with resin microspheres 26 pts, prior external beam radiation in 7 pts, prior glass microspheres in 2 pts, prior systemic radiotherapy in 2 pts, and prior stereotactic liver radiation in 1 pt. Liver function was stable and adequate in all patients after additional liver radiation, and no pts developed radiation-induced liver dysfunction (RILD) or veno-occlusive disease (VOD). The percentage of shunting to the lung decreased with retreatment. Conclusions: Repeated implantation in the liver with Y90-microspheres is safe in patients that have sufficient liver function and reserve based on known and accepted laboratory parameters already used for selection of microsphere therapy. No acute life-threatening, fatal, or late liver damage was observed, RILD or VOD. No specific dose reduction is recommended for retreatment of the liver.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Liver Tolerance to Repeat 90Y-Microsphere Radioembolization
Patrick McNeillie, MS2,
Patrick McNeillie, MS2
University of North Carolina
, Chapel Hill School of Medicine and Wake Radiology Oncology, PLLC
Search for other works by this author on:
Andrew S. Kennedy, MD, FACRO,
Andrew S. Kennedy, MD, FACRO
University of North Carolina
, Chapel Hill School of Medicine and Wake Radiology Oncology, PLLC
Search for other works by this author on:
William Dezarn, PhD, DABR,
William Dezarn, PhD, DABR
University of North Carolina
, Chapel Hill School of Medicine and Wake Radiology Oncology, PLLC
Search for other works by this author on:
Scott L. Sailer, MD,
Scott L. Sailer, MD
University of North Carolina
, Chapel Hill School of Medicine and Wake Radiology Oncology, PLLC
Search for other works by this author on:
Mary England, RN, BSN,
Mary England, RN, BSN
University of North Carolina
, Chapel Hill School of Medicine and Wake Radiology Oncology, PLLC
Search for other works by this author on:
Caroll Overton, MD
Caroll Overton, MD
University of North Carolina
, Chapel Hill School of Medicine and Wake Radiology Oncology, PLLC
Search for other works by this author on:
Patrick McNeillie, MS2
University of North Carolina
, Chapel Hill School of Medicine and Wake Radiology Oncology, PLLC
Andrew S. Kennedy, MD, FACRO
University of North Carolina
, Chapel Hill School of Medicine and Wake Radiology Oncology, PLLC
William Dezarn, PhD, DABR
University of North Carolina
, Chapel Hill School of Medicine and Wake Radiology Oncology, PLLC
Scott L. Sailer, MD
University of North Carolina
, Chapel Hill School of Medicine and Wake Radiology Oncology, PLLC
Mary England, RN, BSN
University of North Carolina
, Chapel Hill School of Medicine and Wake Radiology Oncology, PLLC
Caroll Overton, MD
University of North Carolina
, Chapel Hill School of Medicine and Wake Radiology Oncology, PLLCJ. Med. Devices. Jun 2008, 2(2): 027539 (1 pages)
Published Online: June 25, 2008
Article history
Published:
June 25, 2008
Citation
McNeillie, P., Kennedy, A. S., Dezarn, W., Sailer, S. L., England, M., and Overton, C. (June 25, 2008). "Liver Tolerance to Repeat 90Y-Microsphere Radioembolization." ASME. J. Med. Devices. June 2008; 2(2): 027539. https://doi.org/10.1115/1.2932344
Download citation file:
Get Email Alerts
Cited By
Context-Driven Design of a Laparoscopic Instrument Cleaner for Use in Rural Low-Resource Hospitals
J. Med. Devices (March 2025)
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles
J. Med. Devices (December 2024)
Review of Blood and Fluid Warming Methods
J. Med. Devices (December 2024)
Related Articles
A New Actuation System With Simulated Electrocardiogram Signal for MR Elastography
J. Med. Devices (June,2010)
Effect of Input Waveform Pattern and Large Blood Vessel Existence on Destruction of Liver Tumor Using Radiofrequency Ablation: Finite Element Analysis
J Biomech Eng (June,2010)
Infrared Thermal Imaging-Based Automatic Tumor Tracking During Breast Cancer Radiotherapy
J. Med. Devices (June,2010)
Pre-Clinical Evaluation of Direct Current Ablation for the Treatment of Benign Prostatic Hyperplasia
J. Med. Devices (June,2009)
Related Proceedings Papers
Related Chapters
Insight into Automated Segmentation Using Deformable Registation in 4D Radiotherapy
International Conference on Computer Technology and Development, 3rd (ICCTD 2011)
The Complementary DNA Segment Cloning and Bioinformatics Analysis of INTS2 Gene in Goose
International Conference on Computer Technology and Development, 3rd (ICCTD 2011)
Role of Artificial Intelligence in Hepatitis B Diagnosis
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3