Robotic surgery has been shown to have many advantages over current minimally invasive surgical techniques; however positioning such devices can be a challenging task for surgical technicians. The only commercially available gastrointestinal surgical robot, the da Vinci® S Surgical System (Intuitive Surgical, Sunnyvale, CA) often requires timely repositioning of the patient, robot, or both when used to perform complicated procedures [1]. Such systems face the same constraints experienced by standard laparoscopic instruments; their inability to work in multiple quadrants of the abdominal cavity hinders their ability to perform complicated surgical procedures. The capability to work within multiple quadrants without repositioning the surgical ports becomes extremely important for complex procedures such as colon resection that require tissue manipulation in multiple quadrants.

Single incision surgical devices have been developed to address this need. Such devices include a miniature in vivo surgical robot that can...

References

References
1.
Choi
,
D. J.
,
Kim
,
S. H.
,
Lee
,
P. J.
,
Kim
,
J.
, and
Woo
,
S. U.
, 2009, “
Single-Stage Totally Robotic Dissection for Rectal Cancer Surgery: Technique and Short-Term Outcome in 50 Consecutive Patients
,”
Dis Colon Rectum.
,
52
, pp.
1824
1830
.10.1007/DCR.0b013e3181b13536
2.
Wortman
,
T. D.
,
Strabala
,
K. W.
,
Lehman
,
A. C.
,
Farritor
,
S. M.
, and
Oleynikov
,
D.
,
2011
, “
Laparoendoscopic Single-Site Surgery Using a Multi-Functional Miniature in vivo Robot
,”
The International Journal of Medical Robotics and Computer Assisted Surgery
,
7
(
1
), pp.
17
21
.10.1002/rcs.362
3.
Piccigallo
,
M.
,
Scarfogliero
,
U.
,
Quaglia
,
C.
,
Petroni
,
G.
,
Valdastri
,
P.
,
Menciassi
,
A.
,
Dario
,
P.
, 2010, “
Design of a Novel Bimanual Robotic System for Single-Port Laparoscopy
,”
IEEE/ASME Transaction on Mechatronics
,
15
, pp.
871
878
.
4.
Ding
,
J.
,
Xu
,
K.
,
Goldman
,
R.
,
Allen
,
P.
,
Fowler
,
D.
, and
Simaan
,
N.
, “
Design, Simulation and Evaluation of Kinematic Alternatives for Insertable Robotic Effectors Platforms in Single Port Access Surgery
,” in Proc. of IEEE International Conference on Robotics and Automation (ICRA)
2010
, Anchorage AK, pp.
1053
1058
.
5.
Nathan
,
C. A.
,
Chakradeo
,
V.
,
Malhotra
,
K.
,
D'Agostino
,
H.
, and
Patwardhan
,
R.
, 2006, “
The Voice-Controlled Robotic Assist Scope Holder AESOP for the Endoscopic Approach to the Sella
,
Skull Base
,
16
(
3
), pp.
123
131
.10.1055/s-2006-939679
6.
Lum
,
M.
,
Friedman
,
D.
,
Sankaranarayanan
,
G.
,
King
,
H.
,
Fodero
,
K.
,
Leuschke
,
R.
,
Hannaford
,
B.
,
Rosen
,
J.
, and
Sinanan
,
M.
,
2009
. “
The RAVEN -Design and Validation of a Telesurgery System
.”
International Journal of Robotics Research
, 28, Online.
7.
Nelson
,
C.
,
Zhang
,
X.
,
Shah
,
B. C.
,
Goed
,
M. R.
, and
Oleynikov
,
D.
,
2009
. “Multipurpose Surgical Robot as a Laparoscope Assistant.” Surgical Endoscopy, Epub ahead of print.
8.
Yoshikawa
,
T.
(
1985
, March).
Manipulability and Redundancy Control of Robotic Mechanisms
. In
Robotics and Automation. Proceedings. 1985 IEEE International Conference on
(Vol. 2, pp.
1004
1009
). IEEE.
You do not currently have access to this content.