An implantable actuator and its accompanying driver circuit are presented for the purpose of lengthening bones and correcting skeletal deformities without requiring physical contact between the operator and the implanted device. This system utilizes magnetic coupling to form a magnetic gear, allowing an external motor to drive an implantable telescoping rod. The accompanying electronics are able to monitor the progress, in the form of turns delivered, as well as detect procedural errors, such as magnet decoupling. The force applied by the implanted telescoping rod can be accurately measured by monitoring the current necessary for the external controller to drive the extension of the implanted rod. After characterization, the system was shown to reliably deliver extension distances within 34 μm and maintain coupling out to 70 mm. The system is also able to measure torques as low as 0.12 mN m. System variability and accuracy of external monitoring are addressed.

References

References
1.
Noonan
,
K. J.
, and
Price
,
C. T.
, 1996, “
Pearls and Pitfalls of Deformity Correction and Limb Lengthening via Monolateral External Fixation
,”
Iowa Orthop. J.
,
16
, pp.
58
69
.http://www.uiortho.com/images/stories/ioj/1996iowaorthojournal.pdfhttp://www.uiortho.com/images/stories/ioj/1996iowaorthojournal.pdf
2.
Sabharwal
,
S.
,
Green
,
S.
,
McCarthy
,
J.
, and
Hamdy
,
R. C.
, 2011, “
What’s New in Limb Lengthening and Deformity Correction
,”
J. Bone Jt. Surg.
,
93
(
2
), pp.
213
221
.
3.
Gross
,
R.
, 1999,“
Leg Lengthening
,”
Lancet
,
354
(
9190
), pp.
1574
1575
.
4.
Aquerreta
,
J. D.
,
Forriol
,
D. F.
, and
Cañadell
,
J.
, 1994,“
Complications of Bone Lengthening
.”
Int. Orthop.
,
18
(
5
), pp.
299
303
.
5.
Guichet
,
J.-M.
,
Deromedis
,
B.
,
Donnan
,
L. T.
,
Peretti
,
G.
,
Lascombes
,
P.
, and
Bado
,
F.
, 2003,“
Gradual Femoral Lengthening With the Albizzia Intramedullary Nail
,”
J. Bone Jt. Surg., Am. Vol.
,
85
(
5
), pp.
838
848
.
6.
Hankemeier
,
S.
,
Pape
,
H.-C. C.
,
Gosling
,
T.
,
Hufner
,
T.
,
Richter
,
M.
, and
Krettek
,
C.
, 2004, “
Improved Comfort in Lower Limb Lengthening With the Intramedullary Skeletal Kinetic Distractor: Principles and Preliminary Clinical Experiences
,”
Arch. Orthop. Trauma Surg.
,
124
(
2
), pp.
129
133
.
7.
Baumgart
,
R.
,
Betz
,
A.
, and
Schweiberer
,
L.
, 1997, “
A Fully Implantable Motorized Intramedullary Nail for Limb Lengthening and Bone Transport
,”
Clin. Orthop. Relat. Res.
,
343
, pp.
135
143
.
8.
Meswania
,
J.
,
Taylor
,
S.
, and
Blunn
,
G.
, 2008, “
Design and Characterization of a Novel Permanent Magnet Synchronous Motor Used in a Growing Prosthesis for Young Patients With Bone Cancer
,”
J. Eng. Med.
,
222
, pp.
393
402
.
9.
Gupta
,
A.
,
Meswania
,
J.
,
Pollock
,
R.
,
Cannon
,
S.
,
Taylor
,
S.
, and
Blunn
,
G.
, 2006, “
Non-Invasive Distal Femoral Expandable Endoprosthesis for Limb-Salvage Surgery in Paediatric Tumours
,”
J. Bone Jt. Surg.
,
88
, pp.
649
654
.
10.
Verkerke
,
G.
,
Koops
,
H.
,
Veth
,
R.
,
van den Kroonenberg
,
H. H.
,
Grootenboer
,
H.
,
Nielsen
,
H.
,
Oldhoff
,
J.
, and
Postma
,
A.
, 1990, “
An Extendable Modular Endoprosthetic System for Bone Tumour Management in the Leg
,”
J. Biomed. Eng.
,
12
, pp.
91
96
.
11.
Cheung
,
K.
,
Cheung
,
J.
,
Samartzis
,
D.
,
Mak
,
K.
,
Wong
,
Y.
,
Cheung
,
W.
,
Akbarnia
,
B.
, and
Luk
,
K.
, 2012, “
Magnetically Controlled Growing Rods For Severe Spinal Curvature in Young Children: A Prospective Case Series
,”
Lancet
,
379
, pp.
1967
1974
.
12.
Neuland
,
A. H.
, 1996, “
Apparatus for Transmitting Power
,” U.S. Patent 1171351.
13.
Ikuta
,
K.
,
Makita
,
S.
, and
Arimoto
,
S.
, 1991, “
Non-Contact Magnetic Gear for Micro Transmission Mechanism
,”
Micro Electro Mechanical Systems, MEMS ’91, Proceedings: An Investigation of Micro Structures, Sensors, Actuators, Machines and Robots
,
IEEE
,
Nara, Japan
, Jan. 30–Feb. 2, pp.
125
130
.
14.
Pohler
,
O.
, 2000, “
Unalloyed Titanium For Implants In Bone Surgery
,”
Injury, Int. J. Care Injured
,
31
, pp.
7
13
.
15.
Rizk
,
J.
,
Nagrial
,
M.
, and
Hellany
,
A.
, 2004, “
Analysis and Design of Magnetic Torque Couplers and Magnetic Gears
,” Vol. 3,
The 4th International Power Electronics and Motion Control Conference
, IPEMC 2004, Xi’an, China, Aug. 14–16, pp.
1799
1804
.
16.
Yao
,
Y. D.
,
Huang
,
D. R.
,
Lin
,
S. M.
, and
Wang
,
S. J.
, 1996, “
Theoretical Computations of the Magnetic Coupling Between Magnetic Gears
,”
IEEE Trans. Magn.
,
32
(
3
), pp.
710
713
.
17.
Yao
,
Y. D.
,
Huang
,
D. R.
,
Lee
,
C. M.
,
Wang
,
S. J.
,
Chiang
,
D. Y.
, and
Ying
,
T. F.
, 1997,
“Magnetic Coupling Studies Between Radial Magnetic Gears
.”
IEEE Trans. Magn.
,
33
(
5
), pp.
4236
4238
.
18.
Yao
,
Y. D.
,
Huang
,
D. R.
,
Hsieh
,
C. C.
,
Chiang
,
D. Y.
, and
Wang
,
S. J.
, 1997, “
Simulation Study of the Magnetic Coupling Between Radial Magnetic Gears
,”
IEEE Trans. Magn.
,
33
(
2
), pp.
2203
2206
.
You do not currently have access to this content.