In this work, the deployment of a self-expanding stent in a stenosed artery was evaluated through finite element analysis. The three-layered structure of the artery and their material properties were measured and implemented in our computational models. The instant outcomes, including lumen gain, tissue prolapse, and stress distribution, were quantified, and the effect of plaque calcification was evaluated. Results showed that the peak wall stress occurred on the media layer regardless of plaque calcification. The calcified plaque mitigated the tissue prolapse and arterial wall stresses in general, compared with the soft plaque. However, the lesion calcification led to a more severe residual stenosis, dogboning effect, and corresponding edge stress concentrations after stenting, which requires pre- and/or post-surgical management.

References

References
1.
Duda
,
S. H.
,
Bosiers
,
M.
,
Pusich
,
B.
,
Huttl
,
K.
,
Oliva
,
V.
,
Muller-Hulsbeck
,
S.
,
Bray
,
A.
,
Luz
,
O.
,
Remy
,
C.
,
Hak
,
J. B.
, and
Beregi
,
J. P.
, 2002, “
Endovascular Treatment of Peripheral Artery Disease With Expanded PTFE-Covered Nitinol Stents: Interim Analysis From a Prospective Controlled Study
,”
Cardiovasc. Intervent. Radiol.
,
25
(
5
), pp.
413
418
.
2.
Bosiers
,
M.
,
Torsello
,
G.
,
Gissler
,
H. M.
,
Ruef
,
J.
,
Muller-Hulsbeck
,
S.
,
Jahnke
,
T.
,
Peeters
,
P.
,
Daenens
,
K.
,
Lammer
,
J.
,
Schroe
,
H.
,
Mathias
,
K.
,
Koppensteiner
,
R.
,
Vermassen
,
F.
, and
Scheinert
,
D.
, 2009, “
Nitinol Stent Implantation in Long Superficial Femoral Artery Lesions: 12-Month Results of the DURABILITY I Study
,”
J. Endovasc. Ther.
,
16
(
3
), pp.
261
269
.
3.
Schillinger
,
M.
,
Sabeti
,
S.
,
Loewe
,
C.
,
Dick
,
P.
,
Amighi
,
J.
,
Mlekusch
,
W.
,
Schlager
,
O.
,
Cejna
,
M.
,
Lammer
,
J.
, and
Minar
,
E.
, 2006, “
Balloon Angioplasty Versus Implantation of Nitinol Stents in the Superficial Femoral Artery
,”
N. Engl. J. Med.
,
354
(
18
), pp.
1879
1888
.
4.
Zahedmanesh
,
H.
, and
Lally
,
C.
, 2009, “
Determination of the Influence of Stent Strut Thickness Using the Finite Element Method: Implications for Vascular Injury and In-Stent Restenosis
,”
Med. Biol. Eng. Comput.
,
47
(
4
), pp.
385
393
.
5.
Morton
,
A. C.
,
Crossman
,
D.
, and
Gunn
,
J.
, 2004, “
The Influence of Physical Stent Parameters Upon Restenosis
,”
Pathol. Biol.
,
52
(
4
), pp.
196
205
.
6.
Pericevic
,
I.
,
Lally
,
C.
,
Toner
,
D.
, and
Kelly
,
D. J.
, 2009, “
The Influence of Plaque Composition on Underlying Arterial Wall Stress During Stent Expansion: The Case for Lesion-Specific Stents
,”
Med. Eng. Phys.
,
31
(
4
), pp.
428
433
.
7.
Auricchio
,
F.
, Di
Loreto
,
M.
, and
Sacco
,
E.
, 2001, “
Finite-Element Analysis of a Stenotic Artery Revascularization Through a Stent Insertion
,”
Comput. Methods Biomech. Biomed. Eng.
,
4
(
3
), pp.
249
263
.
8.
Migliavacca
,
F.
,
Petrini
,
L.
,
Colombo
,
M.
,
Auricchio
,
F.
, and
Pietrabissa
,
R.
, 2002, “
Mechanical Behavior of Coronary Stents Investigated Through the Finite Element Method
,”
J. Biomech.
,
35
(
6
), pp.
803
811
.
9.
Wu
,
W.
,
Wang
,
W. Q.
,
Yang
,
D. Z.
, and
Qi
,
M.
, 2007, “
Stent Expansion in Curved Vessel and Their Interactions: A Finite Element Analysis
,”
J. Biomech.
,
40
(
11
), pp.
2580
2585
.
10.
Liang
,
D. K.
,
Yang
,
D. Z.
,
Qi
,
M.
, and
Wang
,
W. Q.
, 2005, “
Finite Element Analysis of the Implantation of a Balloon-Expandable Stent in a Stenosed Artery
,”
Int. J. Cardiol.
,
104
(
3
), pp.
314
318
.
11.
Early
,
M.
,
Lally
,
C.
,
Prendergast
,
P. J.
, and
Kelly
,
D. J.
, 2009, “
Stresses in Peripheral Arteries Following Stent Placement: A Finite Element Analysis
,”
Comput. Methods Biomech. Biomed. Eng.
,
12
(
1
), pp.
25
33
.
12.
Harvey
,
S.
, 2010, “
Comprehensive Nitinol Stent Finite Element Numerical Simulations: From Shape Setting and Deployment, Through Fatigue Life Predictions in a Realistic Peripheral Human Artery Subjected to Pulsatile and Articulation Loading Conditions
,”
Proceedings of the International Conference on Shape Memory and Superelastic Technologies
,
Pacific Grove, CA
.
13.
Conti
,
M.
,
Auricchio
,
F.
, De
Beule
,
M.
, and
Verhegghe
,
B.
, 2009, “
Numerical Simulation of Nitinol Peripheral Stents: From Laser-Cutting to Deployment in a Patient Specific Anatomy
,”
Proceedings of the 8th European Symposium on Martensitic Transformations
,
Prague, Czech Republic
.
14.
Wu
,
W.
,
Qi
,
M.
,
Liu
,
X. P.
,
Yang
,
D. Z.
, and
Wang
,
W. Q.
, 2007, “
Delivery and Release of Nitinol Stent in Carotid Artery and Their Interactions: A Finite Element Analysis
,”
J. Biomech.
,
40
(
13
), pp.
3034
3040
.
15.
Rebelo
,
N.
,
Walker
,
N.
, and
Foadian
,
H.
, 2001, “
Simulation of Implantable Nitinol Stents
,”
Proceedings of the 2001 Abaqus Users conference
,
Providence, RI
.
16.
Schulze-Bauer
,
C. A.
,
Morth
,
C.
, and
Holzapfel
,
G. A.
, 2003, “
Passive Biaxial Mechanical Response of Aged Human Iliac Arteries
,”
J. Biomech. Eng.
,
125
(
3
), pp.
395
406
.
17.
Kim
,
J. H.
,
Kang
,
T. J.
, and
Yu
,
W. R.
, 2008, “
Mechanical Modeling of Self-Expandable Stent Fabricated Using Braiding Technology
,”
J. Biomech.
,
41
(
15
), pp.
3202
3212
.
18.
Holzapfel
,
G. A.
,
Sommer
,
G.
,
Gasser
,
C. T.
, and
Regitnig
,
P.
, 2005, “
Determination of Layer-Specific Mechanical Properties of Human Coronary Arteries With Nonatherosclerotic Intimal Thickening and Related Constitutive Modeling
,”
Am. J. Physiol. Heart Circ. Physiol.
,
289
(
5
), pp.
H2048
2058
.
19.
Migliavacca
,
F.
,
Petrini
,
L.
,
Massarotti
,
P.
,
Schievano
,
S.
,
Auricchio
,
F.
, and
Dubini
,
G.
, 2004, “
Stainless and Shape Memory Alloy Coronary Stents: A Computational Study on the Interaction With the Vascular Wall
,”
Biomech. Model. Mechanobiol.
,
2
(
4
), pp.
205
217
.
20.
Albrecht
,
D.
,
Kaspers
,
S.
,
Fussl
,
R.
,
Hopp
,
H. W.
, and
Sechtem
,
U.
, 1996, “
Coronary Plaque Morphology Affects Stent Deployment: Assessment by Intracoronary Ultrasound
,”
Cathet. Cardiovasc. Diagn.
,
38
(
3
), pp.
229
235
.
21.
Tsutsumi
,
M.
,
Aikawa
,
H.
,
Onizuka
,
M.
,
Iko
,
M.
,
Kodama
,
T.
,
Nii
,
K.
,
Hamaguchi
,
S.
,
Etou
,
H.
,
Sakamoto
,
K.
, and
Kazekawa
,
K.
, 2008, “
Carotid Artery Stenting for Calcified Lesions
,”
AJNR Am. J. Neuroradiol.
,
29
(
8
), pp.
1590
1593
.
22.
Elezi
,
S.
,
Kastrati
,
A.
,
Neumann
,
F. J.
,
Hadamitzky
,
M.
,
Dirschinger
,
J.
, and
Schomig
,
A.
, 1998, “
Vessel Size and Long-Term Outcome After Coronary Stent Placement
,”
Circulation
,
98
(
18
), pp.
1875
1880
.
23.
Krankenberg
,
H.
,
Schluter
,
M.
,
Steinkamp
,
H. J.
,
Burgelin
,
K.
,
Scheinert
,
D.
,
Schulte
,
K. L.
,
Minar
,
E.
,
Peeters
,
P.
,
Bosiers
,
M.
,
Tepe
,
G.
,
Reimers
,
B.
,
Mahler
,
F.
,
Tubler
,
T.
, and
Zeller
,
T.
, 2007, “
Nitinol Stent Implantation Versus Percutaneous Transluminal Angioplasty in Superficial Femoral Artery Lesions up to 10 cm in Length: The Femoral Artery Stenting Trial (FAST)
,”
Circulation
,
116
(
3
), pp.
285
292
.
24.
Taneja
,
M.
,
Tay
,
K. H.
,
Sebastian
,
M.
,
Pasupathy
,
S.
,
Lin
,
S. E.
,
Teo
,
T.
,
Low
,
R.
,
Irani
,
F.
, G.,
Chng
,
S. P.
,
Dewan
,
A.
, and
Tan
,
B. S.
, 2009, “
Self-Expanding Nitinol Stents in Recanalisation of Long-Length Superficial Femoral Artery Occlusions in Patients With Critical Limb Ischaemia
,”
Singapore Med. J.
,
50
(
12
), pp.
1184
1188
.
25.
Thubrikar
,
M. J.
, 2007, “
Stress-Concentration in the Artery I
,”
Vascular Mechanics and Pathology
,
Springer
,
New York
, Chap. 6.
26.
Roguin
,
A.
,
Grenadier
,
E.
,
Linn
,
S.
,
Markiewicz
,
W.
, and
Beyar
,
R.
, 1999, “
Continued Expansion of the Nitinol Self-Expanding Coronary Stent: Angiographic Analysis and 1-Year Clinical Follow-Up
,”
Am. Heart J.
,
138
(
2 Pt 1
), pp.
326
333
.
27.
Willfort-Ehringer
,
A.
,
Ahmadi
,
R.
,
Gruber
,
D.
,
Gschwandtner
,
M. E.
,
Haumer
,
A.
,
Haumer
,
M.
, and
Ehringer
,
H.
, 2004, “
Arterial Remodeling and Hemodynamics in Carotid Stents: A Prospective Duplex Ultrasound Study Over 2 Years
,”
J. Vasc. Surg.
,
39
(
4
), pp.
728
734
.
28.
Hong
,
M. K.
,
Park
,
S. W.
,
Lee
,
C. W.
,
Kang
,
D. H.
,
Song
,
J. K.
,
Kim
,
J. J.
, and
Park
,
S. J.
, 2000, “
Long-Term Outcomes of Minor Plaque Prolapsed Within Stents Documented With Intravascular Ultrasound
,”
Cathet. Cardiovasc. Interv.
,
51
(
1
), pp.
22
26
.
29.
Jang
,
I. K.
,
Tearney
,
G.
, and
Bouma
,
B.
, 2001, “
Visualization of Tissue Prolapse Between Coronary Stent Struts by Optical Coherence Tomography - Comparison With Intravascular Ultrasound
,”
Circulation
,
104
(
22
), p.
2754
.
30.
Siewiorek
,
G. M.
,
Finol
,
E. A.
, and
Wholey
,
M. H.
, 2009, “
Clinical Significance and Technical Assessment of Stent Cell Geometry in Carotid Artery Stenting
,”
J. Endovasc. Ther.
,
16
(
2
), pp.
178
188
.
31.
Kan
,
H. C.
, 2010, “
Investigation of Plaque Effects on CardiovascularStent System
,”
Proceedings of the 4th International Conference on Bioinformatics and Biomedical Engineering (iCBBE)
,
Chengdu, P. R. C.
32.
Melzer
,
A.
, and
Stoeckel
,
D.
, 2010, “
Function and Performance of Nitinol Vascular Implants
,”
Open Med. Devices J.
,
2
, pp.
32
41
.
33.
Sanmartin
,
M.
,
Goicolea
,
J.
,
Alfonso
,
F.
,
Escaned
,
J.
,
Flores
,
A. A.
,
Fernandez-Ortiz
,
A.
,
Banuelos
,
C.
,
Hernandez-Antolin
,
R. A.
, and
Macaya
,
C.
, 2002, “
Implications of Late Expansion of Self-Expanding Stents on Neointimal Response: A Serial Study With Intravascular Ultrasound
,”
Rev. Esp. Cardiol.
,
55
(
1
), pp.
16
24
.
34.
Lownie
,
S. P.
,
Pelz
,
D. M.
,
Lee
,
D. H.
,
Men
,
S.
,
Gulka
,
I.
, and
Kalapos
,
P.
, 2005, “
Efficacy of Treatment of Severe Carotid Bifurcation Stenosis by Using Self-Expanding Stents Without Deliberate Use of Angioplasty Balloons
,”
AJNR Am. J. Neuroradiol.
,
26
(
5
), pp.
1241
1248
.
35.
Zhao
,
H. Q.
,
Nikanorov
,
A.
,
Virmani
,
R.
,
Jones
,
R.
,
Pacheco
,
E.
, and
Schwartz
,
L. B.
, 2009, “
Late Stent Expansion and Neointimal Proliferation of Oversized Nitinol Stents in Peripheral Arteries
,”
Cardiovasc. Intervent. Radiol.
,
32
(
4
), pp.
720
726
.
36.
Timmins
,
L. H.
,
Meyer
,
C. A.
,
Moreno
,
M. R.
, and
Moore
,
J. E.
, 2008, “
Effects of Stent Design and Atherosclerotic Plaque Composition on Arterial Wall Biomechanics
,”
J. Endovasc. Ther.
,
15
(
6
), pp.
643
654
.
37.
Colombo
,
A.
,
Stankovic
,
G.
, and
Moses
,
J. W.
, 2002, “
Selection of Coronary Stents
,”
J. Am. Coll. Cardiol.
,
40
(
6
), pp.
1021
1033
.
38.
Liao
,
R.
,
Green
,
N. E.
,
Chen
,
S. Y.
,
Messenger
,
J. C.
,
Hansgen
,
A. R.
,
Groves
,
B. M.
, and
Carroll
,
J. D.
, 2004, “
Three-Dimensional Analysis of in vivo Coronary Stent–Coronary Artery Interactions
,”
Int. J. Card. Imaging
,
20
(
4
), pp.
305
313
.
39.
Gu
,
L. X.
,
Zhao
,
S. J.
,
Muttyam
,
A. K.
, and
Hammel
,
J. M.
, 2010, “
The Relation Between the Arterial Stress and Restenosis Rate After Coronary Stenting
,”
J. Med. Devices
,
4
(
3
),
031005
.
40.
Shimada
,
Y.
,
Kataoka
,
T.
,
Courtney
,
B. K.
,
Morino
,
Y.
,
Bonneau
,
H. N.
,
Yock
,
P. G.
,
Grube
,
E.
,
Honda
,
Y.
, and
Fitzgerald
,
P. J.
, 2006, “
Influence of Plaque Calcium on Neointimal Hyperplasia Following Bare Metal and Drug-Eluting Stent Implantation
,”
Cathet. Cardiovasc. Interv.
,
67
(
6
), pp.
866
869
.
41.
Veress
,
A. I.
,
Vince
,
D. G.
,
Anderson
,
P. M.
,
Cornhill
,
J. F.
,
Herderick
,
E. E.
,
Klingensmith
,
J. D.
,
Kuban
,
B. D.
,
Greenberg
,
N. L.
, and
Thomas
,
J. D.
, 2000, “
Vascular Mechanics of the Coronary Artery
,”
Z. Kardiol.
,
89
(Suppl. 2), pp.
92
100
.
42.
Lally
,
C.
,
Dolan
,
F.
, and
Prendergast
,
P. J.
, 2005, “
Cardiovascular Stent Design and Vessel Stresses: A Finite Element Analysis
,”
J. Biomech.
,
38
(
8
), pp.
1574
1581
.
You do not currently have access to this content.