Endoscopy is a minimally invasive procedure using instruments that pass through the body for diagnostic purposes and minimizes the risks associated with open surgery. Colonoscopy can viewed as an endoscopic procedure of the colon. Colonoscopy may cause extreme discomfort to the patient and also carries the risks of perforating the lining of the colon, splenic ruptures, or bleeding. The technology is an endoscope that has an exoskeleton structure of controllable stiffness and a highly flexible stem. The device saves the patient from the pain caused by the shaft of a colonoscope when it is guided from the anus to the end of the sigmoid colon. The stiffenable sheath guides the shaft of the colonoscope up to the end of the sigmoid colon to avoid looping the shaft of the colonoscope. A prototype of the device was built and tested to validate its effectiveness. In order to further improve the performance of the device, skilled endoscopists tested and validated the device using a colonoscopy training model. The colonoscopy training model is comprised of a configurable rubber colon, a human torso, a display, and sensing part. It measures the forces caused by the distal tip and the shaft of the colonoscope and the pressure to open up the lumen. The force sensors at the rubber colon constraints measure the forces, and the real-time display panel will show the results to the colonoscopist and record the data for analysis. The endoscopy sheath device improves the process of endoscopy by reducing the mechanical trauma and loops caused by the shaft of the endoscope. With the guide provided by the colonoscope sheath, the forces to the constraints of a colon are significantly decreased in the sigmoid colon. The colonoscope sheath helps to reduce the force to constraints of the colon and isolates the direct contact between the shaft of a colonoscope and a colon wall up to the end of the sigmoid colon. For the complicated shape of the colon, the endoscopy sheath also solved possible looping problems. The colonoscope training model effectively measures the forces and makes it possible to validate the effectiveness of the endoscopy sheath.

References

1.
Dafnis
,
G.
,
Ekbom
,
A.
,
Pahlman
,
L.
, and
Blomqvist
,
P.
, 2001, “
Complications of Diagnostic and Therapeutic Colonoscopy Within a Defined Population in Sweden
,”
Gastrointest. Endosc.
,
54
, pp.
302
309
.
2.
Demling Classen Fruhmorgen
, 1975,
Atlas of Enteroscopy
,
Springer
,
Berlin
.
3.
Dreyfuss
,
J. R.
, and
Janower
,
M. L.
, 1980,
Radiology of the Colon
,
Waverly
,
Baltimore
.
4.
Phee
,
S. J.
,
Ng
,
W. S.
,
Chen
,
I. M.
,
Seow-Choen
,
F.
, and
Davies
,
B. L.
, 1997, “
Locomotion and Steering Aspects in Automation of Colonoscopy Part One: A Literature Review
,”
IEEE Eng. Med. Biol. Mag.
,
16
(
6
), pp.
85
96
.
5.
Phee
,
S. J.
,
Ng
,
W. S.
,
Chen
,
I. M.
,
Seow-Choen
,
F.
, and
Davies
,
B. L.
, 1998, “
Automation of Colonoscopy Part II: Visual-Control Aspects
,”
IEEE Eng. Med. Biol. Mag.
,
17
(
3
), pp.
81
98
.
6.
Ikuta
,
K.
,
Tsukamoto
,
M.
, and
Hirose
,
S.
, 1988, “
Shape Memory Alloy Servo Actuator System with Electric Resistance Feedback and Application for Active Endoscope
,” Proceedings of the 1988 IEEE International Conference on Robotics and Automation, pp.
427
430
.
7.
A.
Menciassi
et al.
, 2002, “
Robotic Solution and Mechanisms for a Semi-Autonomous Endoscope
,”
International Conference on Intelligent Robotics and Systems
,
EPFL, Lausanne
,
Switzerland
, pp.
1379
1384
.
8.
Ng
,
W. S.
,
Phee
,
S. J.
,
Seow
,
C.
, and
Davies
,
B. L.
, 2000, “
Development of a Robotic Colonoscope
,”
Dig. Endosc.
,
12
, pp.
131
135
.
9.
Slatkin
,
A. B.
, and
Burdick
,
J.
, 1999, “
The Development of a Robotic Endoscope
,” Proceedings of the 1991 IEEE International Conference on Robotics and Automation, pp.
2582
2591
.
10.
Hoeg
,
H. D.
,
Slatkin
,
A. B.
Burdick
,
J. W.
, and
Grundfest
,
W. S.
, 2000, “
Biomedical Model of the Small Intestine as Required for the Design and Operation of a Robotic Endoscope
,”
Proceedings of the 2000 IEEE International Conference on Robotics and Automation
,
San Francisco
, CA, pp.
1599
1606
.
11.
Mangan
,
E. V.
,
Kingsley
,
D. A.
,
Quinn
,
R. D.
, and
Chiel
,
H. J.
, 2002, “
Development of a Peristaltic Endoscope
,”
IEEE International Conference on Robotics and Automation
,
Washington
, DC, pp.
347
352
.
12.
Peirs
,
J.
,
Reynaerts
,
D.
, and
Van Brussel
,
H.
, 2000, “
A Miniature Manipulator for Integration in a Self-Propelling Endoscope
,”
EUROSENSORS XIV, the 14th European Conference on Solid-State Transducers
, Copenhagen,
Denmark
, pp.
309
312
.
13.
Peirs
,
J.
et al.
, 2000, “
A Miniature Manipulator for Integration in a Self-Propelling Endoscope
,”
EUROSENSORS XIV, 14th European Conference on Solid-State Transducers
, Copenhagen,
Denmark
, pp.
309
312
.
14.
Panescu
,
D.
, 2005, “
Emerging Technologies: An Imaging Pill for Gastrointestinal Endoscopy
,”
IEEE Eng. Med. Biol. Mag.
,
24
(
4
), pp.
12
14
.
15.
Kim
,
T. S.
,
Kim
,
B.
,
Cho
,
D. D.
,
Song
,
S. Y.
,
Dario
,
P.
, and
Sitti
,
M.
, 2006, “
Fusion of Biomedical Microcapsule Endoscope and Microsystem Technology
,”
The 13th International Conference on Solid-State Sensors, Actuators and Microsystems
, Seoul,
Korea
, pp.
9
14
.
16.
Kim
,
B.
,
Lee
,
S.
,
Park
,
J. H.
, and
Park
,
J.-O.
, 2005, “
Design and Fabrication of a Locomotive Mechanism for Capsule-Type Endoscopes Using Shape Memory Alloys (SMAs)
,”
IEEE/ASME Trans. Mechatron.
,
10
(
1
), pp.
77
86
.
17.
Kim
,
B.
,
Lee
,
S.
,
Park
,
J. H.
, and
Park
,
J.-O.
, 2004, “
Inchworm-Like Microrobot for Capsule Endoscope
,”
Proceedings of the 2004 IEEE International Conference on Robotics and Biometrics
, Shenyang,
China
, pp.
458
463
.
18.
Reynaerts
,
D.
,
Peirs
,
J.
, and
Van Brussel
,
H.
, 1999, “
Shape Memory Micro-Actuation for a Gastro-Intestinal Intervention System
,”
Sens. Actuators
,
77
, pp.
157
166
.
19.
Sendoh
,
M.
,
Ishiyama
,
K.
, and
Arai
,
K.-I.
, 2003, “
Fabrication of Magnetic Actuator for Use in a Capsule Endoscope
,”
IEEE Trans. Magn.
,
39
(
5
), pp.
3232
3234
.
20.
Sturges
,
R. H.
, and
Laowattana
, 1993, “
A Flexible, Tendon-Controlled Device for Endoscopy
,”
The Int. J. Robot. Res.
,
12
(
2
), pp.
121
131
.
21.
Swanstrom
,
L. L.
et al.
, 2005, “
Development of a New Access Device for Transgastric Surgery
,”
J. Gastrointest. Surg.
,
9
, pp.
1129
1137
.
22.
Pai
,
R. D.
et al.
, 2007, “
Endoscopic Evaluation of the Defunctionalized Stomach by Using ShapeLock Technology
,”
Gastrointest. Endosc.
,
66
(
3
), pp.
578
581
.
23.
Hawari
and
Pasricha
, 2007, “
Going for the Loop—A Unique Overtube for the Difficult Colonoscopy
,”
J. Clin. Gastroenterol.
,
41
(
2
), pp.
138
140
.
24.
Rex
et al.
, 2005, “
Insertability and Safety of a Shape-Locking Device for Colonoscopy
,”
Am. J. Gastroenterol.
,
100
, pp.
817
820
.
25.
Choi
,
J.
, and
Sturges
,
R. H.
, 2004, “
Preliminary Element Design and Analysis of a Smart Endoscope
,”
Flexible Automation & Intelligent Manufacturing
,
Toronto, Canada
.
26.
Choi
,
J.
, and
Sturges
,
R. H.
, 2004, “
Design and Simulation of a Smart Endoscope
,”
Intelligent Manipulation and Grasping
,
Genoa, Italy
.
27.
Choi
,
J.
, and
Sturges
,
R. H.
, 2004, “
Design and Simulation of a Smart Endoscope
,”
ASME International Mechanical Engineering Congress and RD&D Expo
, Anaheim,
California
.
28.
Viacheslav
,
I.
,
Egorov
,
I.
,
Schastlivtsev
,
V.
et al.
, 2002, “
Mechanical Properties of the Human Gastrointestinal Tract
,”
J. Biomech.
,
35
(
10
), pp.
1417
1425
.
29.
Brouwer
,
I.
,
Ustin
,
J.
,
Bentley
,
L.
,
Sherman
,
A.
,
Dhruv
,
N.
, and
Tendick
,
F.
, 2001, “
Measuring In Vivo Animal Soft Tissue Properties for Haptic Modeling in Surgical Simulation
,”
Stud. Health Technol. Inform.
,
81
, pp.
69
74
.
30.
Gutkowski
,
L. J.
, and
Kinzel
,
G. L.
, 1992, “
A Coulomb Friction Model for Spherical Joints
,”
ASME Robotics, Spatial Mechanisms and Mechanical Systems
,
45
, pp.
243
250
.
31.
Faraz
,
A.
, and
Payandeh
,
S.
, 2001, “
Towards Approximate Models of Coulomb Frictional Moments in: (I) Revolute Pin Joints and (II) Spherical-Socket Ball Joints
,”
J. Eng. Mech.
,
40
, pp.
283
396
.
32.
Shin
,
Y. J.
, and
Kim
,
C. H.
, 1991, “
An Analytical Solution for Spherical Joint Mechanisms Including Coulomb Friction
,”
The 6th International Pacific Conference on Automotive Engineering
, Vol.
I
, pp.
383
389
.
33.
Choi
,
J. H.
,
Ravindra
,
K.
,
Robert
,
R.
, and
Drozek
,
D.
, 2011, “
Preliminary Development of Colonoscopy Training Model
,”
Medical Devices: Evidence and Research
,
4
, pp.
1
12
.
34.
Hayee
,
B.
,
Rowbotham
,
D.
,
Saxena
,
V.
, and
Mcnair
,
A.
, 2006, “
Do Variable Stiffness Colonoscopes Really Offer an Advantage?
Gastrointest. Endosc.
,
63
(
5
), pp.
AB189
AB189
.
35.
Othman
,
M.
,
Bradley
,
A.
, and
Roy
,
P.
, 2006, “
Is Variable Stiffness Colonoscope Better Than Regular Adult Colonoscope for Colonoscopy? Meta-Analysis of Randomized Controlled Trials
,”
Gastrointest. Endosc.
,
63
(
5
), pp.
AB98
AB98
.
36.
Rodriguez
,
S.
,
Ormseth
,
E.
, and
Tsuchida
,
A.
, 2003, “
Bowel Perforation with the Variable Stiffness Colonoscope
,”
Gastrointest. Endosc.
,
57
(
2
), pp.
271
273
.
You do not currently have access to this content.