No dependable method has yet been established to find time-dependent concentrations of substances injected into the intervertebral disk. This study investigated the feasibility of microdialysis in the measurement of local concentrations of a low-molecular weight drug in the human lumbar disk. A quasi-static experiment and a dynamic computer finite element simulation were used to study the spread of lidocaine in the lumbar disk. Fresh-frozen cadaveric lumbar motion segments were immersed in a 0.1% lidocaine HCl solution for 6 days prior to continuous microdialysis sampling for 30 min at the posterolateral annulus. Samples were collected every 10 min, for a total of three samples per probe. To maintain quasi-static conditions, where the output of lidocaine was equal to the diffusion rate, the microdialysis flow rate was set to . The finite element model treated the disk as poroelastic tissue under compressive load and introduced 1 ml of 4% lidocaine into the nucleus pulposus. Higher microdialysis flow rates suffered from significant losses during consecutive recoveries. Relative recovery in the annulus at was found to be of the initial solution. This was determined to be a result of low diffusivity of lidocaine through tissue. The FEA model predicted low diffusivity of lidocaine and slow transport to the posterolateral annulus if no fissures were present in the annulus. The results from in vitro experiments and computer simulations showed that while microdialysis can take reliable concentration measurements in the posterolateral annulus, probe placement near a fissure is critical if a measurement is to be made immediately following injection of a drug into the nucleus.
Skip Nav Destination
e-mail: jennibuckleyphd@gmail.com
Article navigation
December 2010
Research Papers
Microdialysis Technique to Quantify Drug Concentration in Human Intervertebral Disks
Hyun Kyu Han,
Hyun Kyu Han
Biomechanical Testing Facility,
UCSF/SFGH Orthopaedic Trauma Institute
, San Francisco, CA
Search for other works by this author on:
Jenni Buckley,
Jenni Buckley
Biomechanical Testing Facility,
e-mail: jennibuckleyphd@gmail.com
UCSF/SFGH Orthopaedic Trauma Institute
, San Francisco, CA
Search for other works by this author on:
Kathy Kursa,
Kathy Kursa
Medtronic Spinal and Biologics
, Sunnyvale, CA
Search for other works by this author on:
Conor O’Neill,
Conor O’Neill
Department of Orthopaedic Surgery,
University of California-San Francisco
, San Francisco, CA
Search for other works by this author on:
Jeffrey Lotz
Jeffrey Lotz
Department of Orthopaedic Surgery,
University of California-San Francisco
, San Francisco, CA
Search for other works by this author on:
Hyun Kyu Han
Biomechanical Testing Facility,
UCSF/SFGH Orthopaedic Trauma Institute
, San Francisco, CA
Jenni Buckley
Biomechanical Testing Facility,
UCSF/SFGH Orthopaedic Trauma Institute
, San Francisco, CAe-mail: jennibuckleyphd@gmail.com
Kathy Kursa
Medtronic Spinal and Biologics
, Sunnyvale, CA
Conor O’Neill
Department of Orthopaedic Surgery,
University of California-San Francisco
, San Francisco, CA
Jeffrey Lotz
Department of Orthopaedic Surgery,
University of California-San Francisco
, San Francisco, CAJ. Med. Devices. Dec 2010, 4(4): 041009 (4 pages)
Published Online: December 6, 2010
Article history
Received:
January 11, 2010
Revised:
November 8, 2010
Online:
December 6, 2010
Published:
December 6, 2010
Citation
Han, H. K., Buckley, J., Kursa, K., O’Neill, C., and Lotz, J. (December 6, 2010). "Microdialysis Technique to Quantify Drug Concentration in Human Intervertebral Disks." ASME. J. Med. Devices. December 2010; 4(4): 041009. https://doi.org/10.1115/1.4003006
Download citation file:
31
Views
Get Email Alerts
Cited By
Validation of a Repurposed pH Monitoring Capsule for Cecal Applications Using Novel Synthetic Cecal Contents
J. Med. Devices (March 2025)
Related Articles
Influence of Fixed Charge Density Magnitude and Distribution on the Intervertebral Disc: Applications of a Poroelastic and Chemical Electric (PEACE) Model
J Biomech Eng (February,2003)
Dependence of Mechanical Behavior of the Murine Tail Disc on Regional Material Properties: A Parametric Finite Element Study
J Biomech Eng (December,2005)
Computational Model of the Cerebral Ventricles in Hydrocephalus
J Biomech Eng (May,2010)
Related Proceedings Papers
Related Chapters
Experimental Studies
Nanoparticles and Brain Tumor Treatment
Characterization and evaluation
Biocompatible Nanomaterials for Targeted and Controlled Delivery of Biomacromolecules
Medicine Distribution Security and Quality Monitoring System Based to RFID
International Conference on Advanced Computer Theory and Engineering, 4th (ICACTE 2011)