An actuated robot arm is designed for use as a gross positioning macro-manipulator that can carry, appropriately orient, precisely position, and firmly “lock” in place different types of micro-robots and surgical tools necessary for applications in minimally invasive therapy. With a simple manipulation protocol, the clinician can easily operate the robot in manual mode. A remote control mode can also be enabled for teleoperation of the robot. The robot’s normally locked braking system and the simple quick-release joint enhance its safety features for emergencies and power shutdown. Robot workspace analysis showed that the singularity regions are outside the usable work envelope of the robot. Performance analysis showed that the robot operates with an average displacement accuracy of 0.58 mm and a roll, pitch, and yaw angular accuracies of 0.26 deg, 0.26 deg, and 0.38 deg, respectively. The sophisticated configuration and joint architecture of the arm enable it to perform and interact efficiently with the constrained and limited workspace of surgical environments. The special features of the proposed robot make it well suited for use with new surgical tools and micro-robots for a range of medical interventions.

1.
Cleary
,
K.
, and
Nguyen
,
C.
, 2001, “
State of the Art Surgical Robotics: Clinical Applications and Technology Challenges
,”
Comput. Aided Surg.
1092-9088,
6
(
6
), pp.
312
328
.
2.
Stoianovici
,
D.
,
Webster
,
R.
, and
Kavoussi
,
L.
, 2002, “
Robotic Tools for Minimally Invasive Urologic Surgery
,” Complications of Urologic Laparoscopic Surgery: Recognition, Management and Prevention, http://pegasus.me.jhu.edu/~rwebster/index_files/pub_files/chapter.pdfhttp://pegasus.me.jhu.edu/~rwebster/index_files/pub_files/chapter.pdf
3.
Yousef
,
B.
, 2007, “
Design of a Robot Manipulator and an Ultrasound Probe Holder for Medical Applications
,” Ph.D. thesis, University of Western Ontario, London, ON, Canada.
4.
Bassan
,
H
., 2007, “
Design, Construction and Control of a Micro Manipulator for Prostate Brachytherapy
,” Ph.D. thesis, University of Western Ontario, London, ON, Canada.
5.
Yousef
,
B.
,
Patel
,
R. V.
, and
Moallem
,
M.
, 2006, “
Macro-Robot Manipulator for Medical Applications
,”
IEEE International Conference on Systems, Man and Cybernetics
, pp.
530
535
.
6.
Davies
,
B.
,
Hilbert
,
R.
,
Timoney
,
A.
, and
Wickham
,
J.
, 1989, “
A Surgeon Robot for Prostatectomies
,”
Proceedings of the Second Workshop on Medical and Healthcare Robots
, Newcastle, pp.
91
101
.
7.
Marescaux
,
J.
,
Leroy
,
J.
,
Rubino
,
F.
,
Smith
,
M.
,
Vix
,
M.
,
Simone
,
M.
, and
Mutter
,
D.
, 2001, “
Transatlantic Robot-Assisted Telesurgery
,”
Nature (London)
0028-0836,
413
, pp.
379
380
.
8.
Guthart
,
G.
, and
Salisbury
,
J.
, 2000, “
The Intuitive Telesurgery System: Overview and Application
,”
Proceedings of the IEEE International Conference on Robotics and Automation (ICRA 2000)
, San Francisco, CA, pp.
618
621
.
9.
Eto
,
M.
, and
Naito
,
S.
, 2006, “
Robotic Surgery Assisted by the ZEUS System
,”
Endouronocology
,
Springer
,
Tokyo
, pp.
39
48
.
10.
Advincula
,
A. P.
, and
Song
,
A.
, 2007, “
The Role of Robotic Surgery in Gynecology
,”
Curr. Opin. Obstet. Gynecol.
1040-872X,
19
(
4
), pp.
331
336
.
11.
Lerner
,
A.
,
Stoianovici
,
D.
,
Whitcomb
,
L.
, and
Kavoussi
,
L.
, 1999, “
A Passive Positioning and Supporting Device for Surgical Robots and Instrumentation
,”
Lecture Notes in Computer Science: Medical Image Computing and Computer-Assisted Interventio (1679)
,
Springer-Verlag
,
Cambridge, UK
, pp.
1052
1061
.
12.
Phee
,
L.
,
Xiao
,
Di
,
Yuen
,
J.
,
Chan
,
C. F.
,
Ho
,
H.
,
Thng
,
C. H.
,
Cheng
,
C.
, and
Ng
,
W.
, 2005, “
Ultrasound Guided Robotic System for Transperineal Biopsy of the Prostate
,”
IEEE Trans. Rob. Autom.
1042-296X,
18
, pp.
1315
1320
.
13.
Bassan
,
H.
,
Patel
,
R. V.
, and
Moallem
,
M.
, 2007, “
A Novel Manipulator for 3D Ultrasound Guided Percutaneous Needle Insertion
,”
IEEE International Conference on Robotics and Automation (ICRA ‘07)
, pp.
617
622
.
14.
Craig
,
J. J.
, 2005,
Introduction to Robotics: Mechanics and Control
, 3rd ed.,
Pearson Education
,
Upper Saddle River, NJ
.
15.
Gosselin
,
C.
, and
Angeles
,
J.
, 1991, “
A Global Performance Index for the Kinematic Optimization of Robot Manipulators
,”
ASME J. Mech. Des.
0161-8458,
113
, pp.
220
226
.
16.
Yousef
,
B.
,
Patel
,
R. V.
, and
Moallem
,
M.
, 2008, “
An Ultrasound Probe Holder for Image-Guided Surgery
,”
ASME J. Med. Devices
1932-6181,
2
(
2
), p.
021002
.
You do not currently have access to this content.