A novel translating bed total body irradiation treatment delivery technique that employs dynamically shaped beams is presented. The patient is translated along the floor on a moving bed through a stationary radiation beam and the shape of the radiation beam is changed dynamically as the patient is moved through it, enabling compensation for local variations in patient thickness and tissue density. We demonstrate that the use of dynamically shaped beams results in greatly improved dose homogeneity compared with standard techniques, which use a single static beam shape. Along a representative dose profile through the lungs of a mock-human body, the maximum range of dose deviation from the average is 5.6% (from +2.7% to 2.9%) for the dynamic beam technique compared with 12.8% (from +3.6% to 9.2%) for the static beam technique. A novel, dual-interlock system that prevents bed motion when the radiation beam is stopped and stops the radiation beam when the bed motor is stopped has also been developed. The dual-interlock not only enhances the safety of the treatment but also ensures accuracy in the delivery of the treatment.

1.
Evans
,
M. D.
,
Larouche
,
R. X.
,
Olivares
,
M.
,
Leger
,
P.
,
Larkin
,
J.
,
Freeman
,
C. R.
, and
Podgorsak
,
E. B.
, 2006, “
Total Body Irradiation With a Reconditioned Cobalt Teletherapy Unit
,”
J. Appl. Clin. Med. Phys.
1526-9914,
7
(
1
), pp.
42
51
.
2.
Hugtenburg
,
R. P.
,
Turner
,
J. R.
,
Baggarley
,
S. P.
,
Pinchin
,
D. A.
,
Oien
,
N. A.
,
Atkinson
,
C. H.
, and
Tremewan
,
R. N.
, 1994, “
Total-Body Irradiation on an Isocentric Linear Accelerator: A Radiation Output Compensation Technique
,”
Phys. Med. Biol.
0031-9155,
39
(
5
), pp.
783
793
.
3.
Hui
,
S. K.
,
Kapatoes
,
J.
,
Fowler
,
J.
,
Henderson
,
D.
,
Olivera
,
G.
,
Manon
,
R. R.
,
Gerbi
,
B.
,
Mackie
,
T. R.
, and
Welsh
,
J. S.
, 2005, “
Feasibility Study of Helical Tomotherapy for Total Body or Total Marrow Irradiation
,”
Med. Phys.
0094-2405,
32
(
10
), pp.
3214
3224
.
4.
2006, “
Practice Guideline for the Performance of Total Body Irradiation
,” American College of Radiology.
5.
Chrétien
,
M.
,
Cote
,
C.
,
Blais
,
R.
,
Brouard
,
L.
,
Roy-Lacroix
,
L.
,
Larochelle
,
M.
,
Roy
,
R.
, and
Pouliot
,
J.
, 2000, “
A Variable Speed Translating Couch Technique for total Body Irradiation
,”
Med. Phys.
0094-2405,
27
(
5
), pp.
1127
1130
.
6.
Sofia
,
J. W.
, 1979, “
Computer Controlled, Multileaf Collimator for Rotational Radiation Therapy
,”
AJR, Am. J. Roentgenol.
0361-803X,
133
(
5
), pp.
956
957
.
7.
Sievinen
,
J.
,
Ulmer
,
W.
, and
Wolfgang
,
K.
, 2005, “
AAA Photon Dose Calculation Model in Eclipse
,” Varian Medical Systems, RAD No. 7170B.
8.
Ulmer
,
W.
,
Pyyry
,
J.
, and
Kaissl
,
W.
, 2005, “
A 3D Photon Superposition/Convolution Algorithm and Its Foundation on Results of Monte Carlo Calculations
,”
Phys. Med. Biol.
0031-9155,
50
(
8
), pp.
1767
1790
.
9.
Hussain
,
A.
,
Villarreal-Barajas
,
J. E.
,
Brown
,
D. W.
, and
Dunscmobe
,
P.
, “
Validation of the Eclipse-AAA Algorithm at Extended SSD
,”
J. Appl. Clin. Med. Phys.
1526-9914, in press.
10.
Quast
,
U.
, 1985, “
Physical Treatment Planning of Total-Body Irradiation: Patient Translation and Beam-Zone Method
,”
Med. Phys.
0094-2405,
12
(
5
), pp.
567
574
.
You do not currently have access to this content.