Abstract

With advances in biotechnology, the field of cryopreservation has been continuously developed and improved. Typical cryo-container was designed with minimal flow to avoid possible structural defects in LN2 tank, which has a higher thermal conductivity than vapor nitrogen tank. If cells are placed in typical cryo-container and stored in VN2 tank, cross-contamination can be prevented, but the cell viability after thawing may be reduced. The structure of typical cryo-containers is not optimized for vaporized nitrogen to flow quickly into the container and its circulation well. Therefore, we proposed new cryo-container models that can maintain mechanical strength while optimizing the fluid flow structure, and performed thermal–structural coupled field analysis on cryo-containers. We confirmed the cryo-containers by comparing the equivalent stress distributions formed around through holes and evaluating thermal equilibrium in the cryogenic steady-state through flow analysis. Prototype cryo-containers and typical cryo-containers were placed in VN2 tank for a period of time to observe temperature changes. As a result, the time it takes to reach the temperature equilibrium has been reduced to 55% level compared with the typical cryo-containers. Additionally, C2C12 and hADMSC cells were checked after storage under two temperature conditions (−80 and −196 °C). In both cell, viability, adhesion, and relative cell proliferation were improved by up to 15–20% in new containers compared to typical products. The developed container is expected to maintain stability well by being applied to storage and transportation of advanced medicines that require cryopreservation.

References

1.
Karow
,
A. M.
, and
Carrier
,
O.
,
1969
, “
Effects of Cryoprotectant Compounds on Mammalian Heart Muscle
,”
Surg., Gynecol. Obstet.
,
128
(
3
), pp.
571
583
.https://pubmed.ncbi.nlm.nih.gov/5777547/
2.
Mazur
,
P.
,
1984
, “
Freezing of Living Cells: Mechanisms and Implications
,”
Am. J. Physiol.
,
247
(
3
), pp.
125
142
.https://journals.physiology.org/doi/pdf/10.1152/ajpcell.1984.247.3.C125
3.
Mazur
,
P.
,
1981
, “
Fundamental Cryobiology and the Preservation of Organs by Freezing
,”
Organ Preservation for Transplantation
, 2nd ed.,
A. M.
Karow
, Jr.
, and
D. E.
Pegg
, eds.,
Marcel Dekker
,
New York
.
4.
Baust
,
J.
,
2007
, “
Properties of Cells and Tissues Influencing Preservation Outcome: Molecular Basis of Preservation-Induced Cell Death
,”
Advances in Biopreservation
,
J.
Baust
, and
J.
Baust
, eds.,
CRC Press
,
New York
, pp.
63
87
.
5.
Van Buskirk
,
R. G.
,
2007
, “
Viability and Functional Assays Used to Assess Preservation Efficacy: The Multiple Endpoint/Tier Approach
,”
Advances in Cryopreservation
,
CRC Press
,
Boca Raton, FL
, pp.
123
142
.
6.
Allegrucci
,
C.
, and
Young
,
L.
,
2007
, “
Differences Between Human Embryonic Stem Cell Lines
,”
Human Reprod. Update
,
13
(
2
), pp.
103
120
.10.1093/humupd/dml041
7.
Jang
,
M.
,
Neuzil
,
P.
,
Volk
,
T.
,
Manz
,
A.
, and
Kleber
,
A.
,
2015
, “
On-Chip Three-Dimensional Cell Culture in Phase guides Improves Hepatocyte Functions In Vitro
,”
Biomicrofluidics
,
9
(
3
), p.
034113
.10.1063/1.4922863
8.
Stacey
,
G.
,
2007
, “
Risk Assessment of Cell Culture Procedures
,”
Medicines From Animal Cell Culture
,
Wiley
,
Chichester
, UK, pp.
569
587
.
9.
Clegg
,
J. S.
,
Seitz
,
P.
,
Seitz
,
W.
, and
Hazlewood
,
C. F.
,
1982
, “
Cellular Responses to Extreme Water Loss: The Water Replacement Hypothesis
,”
Cryobiology
,
19
(
3
), pp.
306
316
.10.1016/0011-2240(82)90159-6
10.
Hunt
,
C.
,
2017
, “
Cryopreservation: Vitrification and Controlled Rate Cooling
,”
Stem Cell Banking: Concepts and Protocols, Methods in Molecular Biology
,
J.
Crook
, and
T.
Ludwig
, eds., Vol.
1590
,
Springer Science+Business Media LLC
, New York, pp.
41
77
.
11.
Jang
,
T. H.
,
Park
,
S. C.
,
Yang
,
J. H.
,
Kim
,
J. Y.
,
Seok
,
J. H.
,
Park
,
U. S.
,
Choi
,
C. W.
,
Lee
,
S. R.
, and
Han
,
J.
,
2017
, “
Cryopreservation and Its Clinical Applications
,”
Integr. Med. Res.
,
6
(
1
), pp.
12
18
.10.1016/j.imr.2016.12.001
12.
Breeden
,
F.
,
LaFountain
,
J.
,
Laurent
,
M.
,
Robert
,
J.
, and
Devireddy
,
R. V.
,
2013
, “
Design of a New Portable Cryostorage Device
,”
ASME J. Med. Devices
,
7
(
1
), p.
014501
.10.1115/1.4023275
13.
Sasaki
,
S.
, and
Ezumi
,
T.
,
2005
, “
Experimental Analysis of Stress Intensity Factor of a High Polymer Having a Crack and a Circular Hole or an Inclusion by Tensile Load
,”
Proceedings Third International Conference on Experimental Mechanics and Third Conference of the Asian Committee on Experimental Mechanics
, Vol.
5852
, Singapore, Nov. 29, pp.
832
837
.10.1117/12.621908
14.
Yoon
,
G. H.
,
2009
, “
Structural Optimization and Numerical Analysis of Multiphysics System
,”
Regular Academic Conference Korean Society of Computational Structural Engineering
, Jeongseon-gun, Gangwon-do, South Korea, Apr. 16, pp.
157
160
.https://www.koreascience.or.kr/article/CFKO200935535996631.kr&sa=U
15.
Elliott
,
G. D.
,
Wang
,
S.
, and
Fuller
,
B. J.
,
2017
, “
Cryoprotectants: A Review of the Actions and Applications of Cryoprotective Solutes That Modulate Cell Recovery From Ultra-Low Temperatures
,”
Cryobiology
,
76
, pp.
74
91
.10.1016/j.cryobiol.2017.04.004
16.
Mo
,
H. J.
,
2019
,
A Study on the Cryopreservation Method and Container Development for Stability of Primary Cells
,
Korean Society of Mold & Dies Engineering
, Cheonan-si, Chungcheongnam-do, South Korea, p.
105
.
17.
Choi
,
Y.
, and
Cho
,
S. W.
,
1998
, “
Information Modeling for Finite Element Analysis Using STEP
,”
Soc. Comput. Des. Eng.
,
3
(
1
), pp.
48
56
.https://www.koreascience.or.kr/article/JAKO199811920957773.view?orgId=anpor&hide=breadcrumb,journalinfo
18.
Jin
,
T.
,
Hong
,
J-p.
,
Zheng
,
H.
,
Tang
,
K.
, and
Gan
,
Z-h.
,
2009
, “
Measurement of Boiling Heat Transfer Coefficient in Liquid Nitrogen Bath by Inverse Heat Conduction Method
,”
J. Zheijang Univ. Sci. A
,
10
(
5
), pp.
691
696
.10.1631/jzus.A0820540
19.
Park
,
S. Y.
,
Rhee
,
G. H.
,
Nam
,
Y. H.
, and
Lyu
,
M.
,
2015
, “
Structural Stability Study Using Thermal and Structural Analysis of a Bimetal Cylinder in an Injection Molding Machine
,”
Polymers
,
39
(
5
), pp.
775
781
.10.7317/pk.2015.39.5.775
20.
Dowling
,
N. E.
,
2012
,
Mechanical Behavior of Materials
, 4th ed.,
Prentice Hall
, Hoboken, NJ.
21.
FDA Guidance, 2020, “Chemistry, Manufacturing, and Control (CMC) Information for Human Gene Therapy Investigational New Drug Applications (
INDs
),” FDA, White Oak, MD, p.
49
.https://www.fda.gov/regulatoryinformation/search-fda-guidance-documents/chemistry-manufacturing-and-control-cmcinformation-human-gene-therapy-investigational-new-drug
You do not currently have access to this content.