An adjustable-length intramedullary (IM) nail may reduce both complications secondary to fracture fixation and manufacturing costs. We hypothesized that our novel nail would have suitable mechanical performance. To test this hypothesis, we manufactured three prototypes and evaluated them in quasi-static axial compression and torsion and quasi-static four-point bending. Prototypes were dynamically evaluated in both cyclic axial loading and four-point bending and torsion-to-failure. The prototypes exceeded expectations; they were comparable in both quasi-static axial stiffness (1.41 ± 0.37 N/m in cervine tibiae and 2.30 ± 0.63 in cadaver tibiae) and torsional stiffness (1.05 ± 0.26 N·m/deg in cervine tibiae) to currently used nails. The quasi-static four-point bending stiffness was 80.11 ± 09.360, greater than reported for currently used nails. A length-variance analysis indicates that moderate changes in length do not unacceptably alter bone-implant axial stiffness. After 103,000 cycles of axial loading, the prototype failed at the locking screws, comparable to locking screw failures seen clinically. The prototypes survived 1,000,000 cycles of four-point bend cyclic loading, as indicated by a consistent phase angle throughout cyclic loading. The torsion-to-failure test suggests that the prototype has adequate resistance to applied torques that might occur during the healing process. Together, these results suggest that our novel IM nail performs sufficiently well to merit further development. If brought to market, this adjustable-length IM nail could reduce both patient complications and healthcare costs.
Skip Nav Destination
Article navigation
December 2017
Design Innovation Paper
A Proximally-Adjustable Variable Length Intramedullary Nail: Ex Vivo Quasi-Static and Cyclic Loading Evaluation
Mark J. Hedgeland,
Mark J. Hedgeland
Mem. ASME
Department of Mechanical and Aeronautical Engineering,
Clarkson University,
8 Clarkson Avenue,
Box 5725,
Potsdam, NY 13699
e-mail: hedgelmj@clarkson.edu
Department of Mechanical and Aeronautical Engineering,
Clarkson University,
8 Clarkson Avenue,
Box 5725,
Potsdam, NY 13699
e-mail: hedgelmj@clarkson.edu
Search for other works by this author on:
Alexander Martin Clark, Jr.,
Alexander Martin Clark, Jr.
Department of Orthopaedic Surgery,
Sharon Hospital,
50 Hospital Hill Road,
Sharon, CT 06069
e-mail: drmartyclark@yahoo.com
Sharon Hospital,
50 Hospital Hill Road,
Sharon, CT 06069
e-mail: drmartyclark@yahoo.com
Search for other works by this author on:
Mario J. Ciani,
Mario J. Ciani
Department of Occupational Therapy,
Clarkson University,
8 Clarkson Avenue,
Box 5882,
Potsdam, NY 13699
e-mail: mciani@clarkson.edu
Clarkson University,
8 Clarkson Avenue,
Box 5882,
Potsdam, NY 13699
e-mail: mciani@clarkson.edu
Search for other works by this author on:
Arthur J. Michalek,
Arthur J. Michalek
Mem. ASME
Department of Mechanical and Aeronautical Engineering,
Clarkson University,
8 Clarkson Avenue,
Box 5725,
Potsdam, NY 13699
e-mail: ajmichal@clarkson.edu
Department of Mechanical and Aeronautical Engineering,
Clarkson University,
8 Clarkson Avenue,
Box 5725,
Potsdam, NY 13699
e-mail: ajmichal@clarkson.edu
Search for other works by this author on:
Laurel Kuxhaus
Laurel Kuxhaus
Mem. ASME
Department of Mechanical and Aeronautical Engineering,
Clarkson University,
8 Clarkson Avenue,
Box 5725,
Potsdam, NY 13699
e-mail: lkuxhaus@clarkson.edu
Department of Mechanical and Aeronautical Engineering,
Clarkson University,
8 Clarkson Avenue,
Box 5725,
Potsdam, NY 13699
e-mail: lkuxhaus@clarkson.edu
Search for other works by this author on:
Mark J. Hedgeland
Mem. ASME
Department of Mechanical and Aeronautical Engineering,
Clarkson University,
8 Clarkson Avenue,
Box 5725,
Potsdam, NY 13699
e-mail: hedgelmj@clarkson.edu
Department of Mechanical and Aeronautical Engineering,
Clarkson University,
8 Clarkson Avenue,
Box 5725,
Potsdam, NY 13699
e-mail: hedgelmj@clarkson.edu
Alexander Martin Clark, Jr.
Department of Orthopaedic Surgery,
Sharon Hospital,
50 Hospital Hill Road,
Sharon, CT 06069
e-mail: drmartyclark@yahoo.com
Sharon Hospital,
50 Hospital Hill Road,
Sharon, CT 06069
e-mail: drmartyclark@yahoo.com
Mario J. Ciani
Department of Occupational Therapy,
Clarkson University,
8 Clarkson Avenue,
Box 5882,
Potsdam, NY 13699
e-mail: mciani@clarkson.edu
Clarkson University,
8 Clarkson Avenue,
Box 5882,
Potsdam, NY 13699
e-mail: mciani@clarkson.edu
Arthur J. Michalek
Mem. ASME
Department of Mechanical and Aeronautical Engineering,
Clarkson University,
8 Clarkson Avenue,
Box 5725,
Potsdam, NY 13699
e-mail: ajmichal@clarkson.edu
Department of Mechanical and Aeronautical Engineering,
Clarkson University,
8 Clarkson Avenue,
Box 5725,
Potsdam, NY 13699
e-mail: ajmichal@clarkson.edu
Laurel Kuxhaus
Mem. ASME
Department of Mechanical and Aeronautical Engineering,
Clarkson University,
8 Clarkson Avenue,
Box 5725,
Potsdam, NY 13699
e-mail: lkuxhaus@clarkson.edu
Department of Mechanical and Aeronautical Engineering,
Clarkson University,
8 Clarkson Avenue,
Box 5725,
Potsdam, NY 13699
e-mail: lkuxhaus@clarkson.edu
1Corresponding author.
Manuscript received March 24, 2017; final manuscript received June 20, 2017; published online August 16, 2017. Assoc. Editor: Rita M. Patterson.
J. Med. Devices. Dec 2017, 11(4): 045001 (7 pages)
Published Online: August 16, 2017
Article history
Received:
March 24, 2017
Revised:
June 20, 2017
Citation
Hedgeland, M. J., Martin Clark, A., Jr., Ciani, M. J., Michalek, A. J., and Kuxhaus, L. (August 16, 2017). "A Proximally-Adjustable Variable Length Intramedullary Nail: Ex Vivo Quasi-Static and Cyclic Loading Evaluation." ASME. J. Med. Devices. December 2017; 11(4): 045001. https://doi.org/10.1115/1.4037260
Download citation file:
91
Views
0
Citations
Get Email Alerts
Cited By
Elliptical Trainer Redesign to Diversify Muscles Recruitment
J. Med. Devices (September 2022)
High-Speed Jet Injector for Pharmaceutical Applications
J. Med. Devices (September 2022)
DynaRing: A Patient-Specific Mitral Annuloplasty Ring With Selective Stiffness Segments
J. Med. Devices (September 2022)
Scale Effects on Performance of BLDC Micromotors for Internal Biomedical Applications: A Finite Element Analysis
J. Med. Devices (September 2022)
Related Articles
An Adjustable-Length Intramedullary Nail: Development and Mechanical Evaluation in Cervine Tibiae
J. Med. Devices (June,2015)
Comparative Evaluation of a Positive-Locking Antirotation Mechanism in the Design of Telescopic Nails for Patients in the Growth Phase
J. Med. Devices (September,2017)
Novel Synthetic Total Disk Model for Mechanical Testing of Nucleus Replacement Devices
J. Med. Devices (March,2008)
Biomechanical Evaluation of an Interfacet Joint Decompression and Stabilization System
J Biomech Eng (July,2014)
Related Proceedings Papers
Related Chapters
Introduction and Definitions
Handbook on Stiffness & Damping in Mechanical Design
Digital Human in Engineering and Bioengineering Applications
Advances in Computers and Information in Engineering Research, Volume 1
Study on Screw Drill Wear When Drilling Low Carbon Stainless Steel and Accompanying Phenomena in the Cutting Zone
International Conference on Instrumentation, Measurement, Circuits and Systems (ICIMCS 2011)