Early diagnostic and treatment of prostate cancer could be achieved using magnetic resonance imaging (MRI) to improve tumor perceptibility. Nonetheless, performing intra-MRI interventions present significant challenges due to intense magnetic fields and limited patient access. This paper presents an MRI-compatible manipulator using elastically averaged binary pneumatic air muscles (PAMs) to orient a needle into a targeted region of the prostate under the command of a physician. The proposed manipulator is based on an all-polymer compliant mechanism designed to make a completely MRI-compatible positioning system. A model based on the PAMs deformation energy is used to design the manipulator so that its discrete workspace, stiffness, and size meet clinically relevant design requirements. The model is also used to study the motion of the device during a state shift. A laboratory prototype of the device shows that the covered workspace, stiffness, and size of the manipulator can meet clinical requirements. Repeatability and accuracy are also acceptable with values of 0.5 mm and 1.7 mm, respectively. Finally, the manipulator’s behavior during state shift describes a hook-shaped motion that is both analytically predicted and experimentally observed.

References

1.
Calle
J.
, and
et Rodriguez
C.
, 2009, “
Cancer Facts and Figures.
2.
Scardino
,
P. T.
, 1989, “
Early Detection of Prostate Cancer
,”
Urol. Clin. North Am.
,
16
(
4
), pp.
635
655
.
3.
Heidenreich
,
A.
,
Aus
,
G.
,
Bolla
,
M.
,
Joniau
,
S.
,
Matveev
,
V. B.
,
Schmid
,
H. P.
, and
et Zattoni
F.
, 2008, “
EAU Guidelines on Prostate Cancer
,”
Eur. Urol.
,
53
(
1
), pp.
68
80
.
4.
Jamis-Dow
,
C. A.
,
Choyke
,
P. L.
,
Jennings
,
S. B.
,
Linehan
,
W. M.
,
Thakore
,
K. N.
, and
et Walther
,
M. M.
, 1996, “
Small (< or = 3-cm) Renal Masses: Detection With CT Versus US and Pathologic Correlation
,”
Radiology
,
198
(
3
), pp.
785
788
.
5.
Madabhushi
,
A.
,
Feldman
,
M.
,
Metaxas
,
D.
,
Tomaszeweski
,
J.
, and
et Chute
D.
, 2005, “
Automated Detection of Prostatic Adenocarcinoma From High-Resolution ex vivo MRI
,”
IEEE Trans. Med. Imaging
,
24
(
12
), pp.
1611
1625
.
6.
Chan
,
T. Y.
,
Chan
,
D. Y.
,
Stutzman
,
K. L.
, and
et Epstein
,
J. I.
, 2001, “
Does Increased Needle Biopsy Sampling of the Prostate Detect a Higher Number of Potentially Insignificant Tumors?
,”
J. Urol
,
166
(
6
), pp.
2181
2184
.
7.
Yuen
,
J.
,
Thng
,
C.
,
Tan
,
P.
,
Khin
,
L.
,
Phee
,
S.
,
Xiao
,
D.
,
Lau
,
W.
,
Ng
,
W.
, and
et Cheng
,
C.
, 2004, “
Endorectal Magnetic Resonance Imaging and Spectroscopy for the Detection of Tumor Foci in Men with Prior Negative Transrectal Ultrasound Prostate Biopsy
,”
J. Urol.
,
171
(
4
), pp.
1482
1486
.
8.
Chinzei
,
K.
,
Hata
,
N.
,
Jolesz
,
F.
, and
et Kikinis
,
R.
, 2000, “
Surgical Assist Robot for the Active Navigation in the Intraoperative MRI: Hardware Design Issues
,” pp.
727
732
, Vol.
1
.
9.
Gassert
,
R.
,
Yamamoto
,
A.
,
Chapuis
,
D.
,
Dovat
,
L.
,
Bleuler
,
H.
, and
et Burdet
,
E.
, 2006, “
Actuation Methods for Applications in MR Environments
,”
Concepts Magn. Reson., Part B
,
29B
(
4
), pp.
191
209
.
10.
Elhawary
,
H.
,
Tse
,
Z. T. H.
,
Hamed
,
A.
,
Rea
,
M.
,
Davies
,
B. L.
, and
et Lamperth
,
M. U.
, 2008, “
The Case for MR-Compatible Robotics: A Review of the State of the Art
,”
Int. J. Med. Rob. Comput. Assist. Surg.
,
4
(
2
), pp.
105
113
.
11.
Wacker
,
F.
,
Hillenbrand
,
C.
,
Elgort
,
D.
,
Zhang
,
S.
,
Duerk
,
J.
, and
et Lewin
,
J.
, 2005, “
MR Imaging-guided Percutaneous Angioplasty and Stent Placement in a Swine ModelComparison of Open- and Closed-bore Scanners1
,”
Acad. Radiol.
,
12
(
9
), pp.
1085
1088
.
12.
D’Amico
,
A. V.
,
Cormack
,
R. A.
, and
et Tempany
,
C. M.
, 2001, “
MRI-Guided Diagnosis and Treatment of Prostate Cancer
,”
N. Engl. J. Med.
,
344
(
10
), pp.
776
777
.
13.
Miller
,
J.
,
Perumalla
,
C.
, and
et Heap
,
G.
, 2005, “
Complications of Transrectal Versus Transperineal Prostate Biopsy
,”
ANZ J. Sur.
,
75
(
1–2
), pp.
48
50
.
14.
Stoianovici
,
D.
,
Song
,
D.
,
Petrisor
,
D.
,
Ursu
,
D.
,
Mazilu
,
D.
,
Muntener
,
M.
,
Schar
,
M.
, and
et Patriciu
,
A.
, 2007, “
MRI Stealth” Robot for Prostate Interventions
,”
Minimally Invasive Ther. Allied Technol.
,
16
(
4
), pp.
241
248
.
15.
Fischer
,
G.
,
Iordachita
,
I.
,
Csoma
,
C.
,
Tokuda
,
J.
,
Mewes
,
P.
,
Tempany
,
C.
,
Hata
,
N.
, and
et Fichtinger
,
G.
, 2008, “
Pneumatically Operated MRI-Compatible Needle Placement Robot for Prostate Interventions
,” pp.
2489
2495
.
16.
Goldenberg
,
A.
,
Trachtenberg
,
J.
,
Kucharczyk
,
W.
,
Yang
,
Yi
,
Haider
,
M.
,
Ma
,
L.
,
Weersink
,
R.
, and
et Raoufi
,
C.
, 2008, “
Robotic System for Closed-Bore MRI-Guided Prostatic Interventions
,”
IEEE/ASME Trans. Mechatron.
,
13
(
3
), pp.
374
379
.
17.
Carpi
,
F.
, and
et Smela
,
É.
, 2009,
Biomedical Applications of Electroactive Polymer Actuators
,
John Wiley and Sons
,
UK
.
18.
Anderson
,
V. V.
, and
et Horn
,
R. C.
, 1967, “
Tensor-Arm Manipulator Design
,”
ASME Trans.
,
67-DE-57
, pp.
1
12
.
19.
Ottaviano
,
E.
,
Ceccarelli
,
M.
, Di
Giorgio
,
J.
, and
et Varone
,
M.
, 2006, “
Design and Evaluation of a Discretely Actuated Multi-Module Parallel Manipulator
,”
Proc. Inst. Mech. Eng., Part C
,
220
(
4
), pp.
513
526
.
20.
Chirikjian
,
G. S.
, 1995, “
Kinematic Synthesis of Mechanisms and Robotic Manipulators With Binary Actuators
,”
J. Mech. Des.
,
117
(
4
), pp.
573
580
.
21.
Mekid
,
S.
, 2008,
Introduction to Precision Machine Design and Error Assessment
,
CRC Press
,
Florida
.
22.
Yang
,
P. H.
, and
et Waldron
,
K.
, 2001, “
Advanced Intelligent Mechatronics
,”
Proceedings IEEE/ASME International Conference on,
” Vol.
2
, pp.
868
873
.
23.
Briot
,
S.
, and
et Bonev
,
I. A.
, 2010, “
Accuracy Analysis of 3T1R Fully-Parallel Robots
,”
Mech. Mach. Theory
,
45
(
5
), pp.
695
706
.
24.
Daerden
,
F.
, and
et Lefeber
,
D.
, 2000, “
Pneumatic Artificial Muscles: Actuators for Robotics and Automation
,”
Eur. J. Mech. Environ. Eng.
,
47
, pp.
10
21
.
25.
Klute
,
G. K.
,
Czerniecki
,
J. M.
, and
et Hannaford
,
B.
, 2000, “
Muscle-like pneumatic actuators for below-knee prostheses.
26.
Gordon
,
K. E.
,
Sawicki
,
G. S.
, and
et Ferris
,
D. P.
, 2006, “
Mechanical Performance of Artificial Pneumatic Muscles to Power an Ankle-Foot Orthosis
,”
J. Biomech.
,
39
(
10
), pp.
1832
1841
.
27.
Koeneman
,
E.
,
Schultz
,
R.
,
Wolf
,
S.
,
Herring
,
D.
, and
et Koeneman
,
J.
, 2004, “
A Pneumatic Muscle Hand Therapy device
,”
Engineering in Medicine and Biology Society, IEMBS’04, 26th Annual International Conference of the IEEE
, pp.
2711
2713
.
28.
Reynolds
,
D. B.
,
Repperger
,
D. W.
,
Phillips
,
C. A.
, and
et Bandry
,
G.
, 2003, “
Modeling the Dynamic Characteristics of Pneumatic Muscle
,”
Ann. Biomed. Eng.
,
31
(
3
), pp.
310
317
.
29.
Plante
,
J.
, and
et Dubowsky
,
S.
, 2008, “
The Calibration of a Parallel Manipulator with Binary Actuation
,”
Advances in Robot Kinematics: Analysis and Design
,
J.
Lenarcic
and
P.
Wenger
(Eds.),
Springer
,
Dordrecht
, pp.
391
398
.
30.
Tadakuma
,
K.
,
DeVita
,
L.
,
Plante
,
J.
,
Shaoze
,
Y.
, and
et Dubowsky
,
S.
, 2008, “
The Experimental Study of a Precision Parallel Manipulator With Binary Actuation: With Application to MRI Cancer Treatment
,” pp.
2503
2508
.
31.
Bak
,
J. B.
,
Landas
,
S. K.
, and
et Haas
,
G. P.
, 2003, “
Characterization of Prostate Cancer Missed by Sextant Biopsy
,”
Clin. Prostate Cancer
,
2
(
2
), pp.
115
118
.
32.
Podder
,
T.
,
Clark
,
D.
,
Sherman
,
J.
,
Fuller
,
D.
,
Messing
,
E.
,
Rubens
,
D.
,
Strang
,
J.
,
Brasacchio
,
R.
,
Liao
,
L.
,
Ng
,
W.
, and
et Yu
,
Y.
, 2006, “
In Vivo Motion and Force Measurement of Surgical Needle Intervention During Prostate Brachytherapy
,”
Med. Phys.
,
33
(
8
), pp.
2915
2922
.
33.
Plante
,
J.
,
Tadakuma
,
K.
,
DeVita
,
L. M.
,
Kacher
,
D. F.
,
Roebuck
,
J. R.
,
DiMaio
,
S. P.
,
Jolesz
,
F. A.
, and
et Dubowsky
,
S.
, 2009, “
An MRI-Compatible Needle Manipulator Concept Based on Elastically Averaged Dielectric Elastomer Actuators for Prostate Cancer Treatment: An Accuracy and MR-Compatibility Evaluation in Phantoms
,”
J. Med. Devices
,
3
(
3
), p.
031005
.
34.
Proulx
,
S.
,
Chouinard
,
P.
,
Lucking Bigue
,
J.
,
Miron
,
G.
, and
et Plante
,
J.
, 2011, “
Design of a MRI-Compatible Dielectric Elastomer Powered Jet Valve
,” San Diego, CA,
79762C
-79762C-
12
.
35.
Amirouche
,
F. M. L.
, 2006,
Fundamentals of Multibody Dynamics: Theory and Applications
,
Birkhäuser
,
Boston
.
36.
Yang
,
Y.
, and
et Feng
,
W.
, 1970, “
On Axisymmetrical Deformations of Nonlinear Membranes
,”
Trans. ASME, J. Appl. Mech.
,
37, Ser E
(
4
), pp.
1002
1011
.
You do not currently have access to this content.