Experimental values of damping and stiffness were determined for an externally pressurized, inherently compensated, compressible squeeze-film damper up to excitation frequencies of 36,000 cycles/min. Experimental values of damping were higher than predicted by a small pressure perturbation theory at low squeeze numbers and less than predicted at high squeeze numbers. Experimental values of air film stiffness were less than the theory predicted at low squeeze numbers and much greater at higher squeeze numbers.