Abstract

The current ASTM F1717 standard specifies the static and fatigue testing conditions for extradiscal spinal implant assemblies. For the lumbar region, the standard stipulates a vertebrectomy model for said tests. While this testing setup has proven effective in analyzing overall construct stiffness, yield load, and displacement for rigid constructs, there is a growing segment of products and cases which amendments to the standard might better represent. One opportunity to evolve the current standard is in integrating test parameters which address the greater flexibility of semirigid or flexible systems such as those made from polymeric or metallic-polymeric materials. Since these rods are considerably more flexible when compared to rigid metallic rods, they create unique testing challenges. In addition, the current standard lacks a specification for testing single-level constructs. Considering that the overall dynamics of single-level cases vary greatly from the current vertebrectomy model, a modification or creation of a standard is needed. For the two reasons presented above, a single-level “discectomy” model has been developed to consider these unique testing conditions.

References

1.
Highsmith
,
J. M.
,
Tumialán
,
L. M.
, and
Rodts
,
G. E.
, Jr.
, “
Flexible Rods and the Case for Dynamic Stabilization
,”
Neurosurg. Focus
, Vol.
22
, No.
1
,
2007
, p. E11. https://doi.org/10.3171/foc.2007.22.1.11
2.
ASTM F1717–04
, “
Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model
,”
Annual Book of ASTM Standards
Vol.
2005
,
ASTM International
,
West Conshohocken, PA
, pp.
807
824
.
3.
Cunningham
,
B. W.
,
Sefter
,
J. C.
,
Shono
,
Y.
, and
McAfee
,
P. C.
, “
Static and Cyclical Biomechanical Analysis of Pedicle Screw Spinal Constructs
,”
Spine
, Vol.
18
, No.
12
, pp.
1677
1688
. https://doi.org/10.1097/00007632-199309000-00017
4.
Eijkelkamp
,
M. F.
,
van Donkelaar
,
C. C.
,
Veldhuizen
,
A. G.
,
van Horn
,
J. R.
,
Huyghe
,
J. M.
, and
Verkerke
,
G. J.
, “
Requirements for an Artificial Intervertebral Disc
,”
Int. J. Artificial Organs
, Vol.
24
,
2001
, pp.
311
321
.
5.
ASTM F2346–05
, “
Standard Test Methods for Static and Dynamic Characterization of Spinal Artificial Discs
,”
Annual Book of ASTM Standards
Vol.
2005
,
ASTM International
,
West Conshohocken, PA
, pp.
1403
1411
.
6.
Schaeren
,
S.
,
Broger
,
I.
, and
Jeanneret
,
B.
, “
Minimum Four-Year Follow-up of Spinal Stenosis With Degenerative Spondylolisthesis Treated With Decompression and Dynamic Stabilization
,”
Spine
, Vol.
33
, No.
18
, pp.
E636
E642
. https://doi.org/10.1097/BRS.0b013e31817d2435
7.
Bothmann
,
M.
,
Kast
,
E.
,
Jens Boldt
,
G.
, and
Oberle
,
J.
, “
Dynesys Fixation for Lumbar Spine Degeneration
,”
Neurosurg Rev.
, Vol.
31
,
2008
, pp.
189
196
. https://doi.org/10.1007/s10143-007-0101-9
8.
Grob
,
D.
,
Benini
,
A.
,
Junge
,
A.
, and
Mannion
,
A. F.
, “
Clinical Experience With the Dynesys Semirigid Fixation System for the Lumbar Spine
,”
Spine
, Vol.
30
, No.
3
, 2005, pp.
324
331
. https://doi.org/10.1097/01.brs.0000152584.46266.25
9.
Ponnappan
,
R. K.
,
Serhan
,
H.
,
Zarda
,
B.
,
Patel
,
R.
,
Albert
,
T.
, and
Vaccaro
,
A. R.
, “
Biomechanical Evaluation and Comparison of Polyetheretherketone Rod System to Traditional Titanium Rod Fixation
,”
Spine J.
, Vol.
9
,
2009
, pp.
263
267
. https://doi.org/10.1016/j.spinee.2008.08.002
10.
Yamamoto
,
I.
,
Panjabi
,
M. M.
,
Trey
Crisco
, and
Oxland
,
T.
, “
Three-Dimensional Movements of the Whole Lumbar Spine and Lumbosacral Joint
,”
Spine
, Vol.
14
, No.
11
,
1989
, pp.
1256
1260
. https://doi.org/10.1097/00007632-198911000-00020
11.
Chaynes
,
P.
,
Sol
,
J.-C.
,
Vaysse
,
Ph.
,
Bécue
,
J.
, and
Lagarrigue
,
J.
, “
Anatomic Bases of Medical, Radiologic and Surgical Techniques Vertebral Pedicle Anatomy in Relation to Pedicle Screw Fixation: A Cadaver Study
,”
Surg. Radiol. Anatomy
, Vol.
23
, No.
2
,
2001
, pp.
85
90
. https://doi.org/10.1007/s00276-001-0085-z
12.
Nockels
,
R.
,
Bamber
,
N. I.
,
Hammers
,
R. L.
, and
Bragg
,
T. M.
, “
Surgical Management of Lumbar Spondylolisthesis With Pedicle Based Semi-Rigid Instrumentation and Arthodesis
,”
Paper Presented at 2008 Congress of Neurosurgical Surgeons (CNS) Annual Meeting
,
Orlando, FL
.
13.
ASTM F2624–05
, “
Standard Test Method for Static, Dynamic, and Wear Assessment of Extra-Discal Spinal Motion Preserving Implants
,”
Annual Book of ASTM Standards
,
ASTM International
,
West Conshohocken, PA
,
2005
, available at: www.astm.org.
14.
Gere
,
J. M.
and
Goodno
,
B. J.
,
Mechanics of Materials
, 7th ed.,
Cengage Learning
,
Toronto, ON
,
2009
.
This content is only available via PDF.