Abstract

Persistent pain, especially anterior knee pain, with or without crepitation, has been a persistent complaint after total knee arthroplasty in both rotating platform posterior stabilized (RP-PS) and fixed bearing posterior stabilized (FB-PS) designs. Because PFC Sigma RP-PS and FB-PS designs have identical femoral components, we hypothesized that the incidence of post-operative pain, anterior knee pain, asymptomatic crepitation, painful crepitation, and painful crepitation requiring scar excision is similar in both designs. Between March 2000 and May 2004, 81 near-consecutive RP-PS Total Knee Replacements (TKRs) were matched to 81 FB-PS knees based on gender, age, and body mass index. Radiographic analysis included alignment, fixation, and patellar tilt. Clinical assessments were performed at the time of follow-up using the Knee Society Scores. The incidence of anterior knee pain and crepitation was investigated using a detailed patient administered questionnaire. The incidence of post-operative pain, anterior knee pain, asymptomatic crepitation, and painful crepitation was similar in both groups (20.9 %, 19.7 %, 1.2 %, and 8.6 % in the RP-PS; and 20.9 %, 18.5 %, 0 %, and 6.1 % in the FB-PS, respectively). The severity of painful crepitation was also similar in both groups. None was excruciating. The incidence of painful crepitation requiring scar excision was slightly higher in the RP-PS group (6.1 % versus 2.4 %) but it was not statistically significant. In conclusion, there is a trend of increased incidence of painful crepitation requiring scar excision in the RP-PS TKR, although it was not statistically significant in this study.

References

1.
Baldini
,
A.
,
Anderson
,
J. A.
,
Zampetti
,
P.
,
Pavlov
,
H.
, and
Sculco
T. P.
, “
A New Patellofemoral Scoring System for Total Knee Arthroplasty
,”
Clin. Orthop. Relat. Res.
, Vol.
452
,
2006
, pp.
150
154
. https://doi.org/10.1097/01.blo.0000238847.34047.90
2.
Barrack
,
R. L.
,
Schrader
,
T.
,
Bertot
,
A. J.
,
Wolfe
,
M. W.
, and
Myers
,
L.
, “
Component Rotation and Anterior Knee Pain After Total Knee Arthroplasty
,”
Clin. Orthop. Relat. Res.
, Vol.
392
,
2001
, pp.
46
55
. https://doi.org/10.1097/00003086-200111000-00006
3.
Murray
,
D. W.
and
Frost
,
S. J.
Pain in the Assessment of Total Knee Replacement
,”
J. Bone Joint Surg. Br.
, Vol.
80
,
1998
, pp.
426
431
. https://doi.org/10.1302/0301-620X.80B3.7820
4.
Popovic
,
N.
and
Lemaire
,
R.
Anterior Knee Pain with a Posterior Stabilized Mobile-Bearing Knee Prosthesis: The Effect of Femoral Component Design
,”
J. Arthroplasty
, Vol.
18
,
2003
, pp.
396
400
. https://doi.org/10.1016/S0883-5403(03)00059-7
5.
Scuderi
,
G. R.
,
Insall
,
J. N.
, and
Scott
N. W.
, “
Patellofemoral Pain After Total Knee Arthroplasty
,”
J. Am. Acad. Orthop. Surg.
, Vol.
2
,
1994
, pp.
239
246
.
6.
Meftah
,
M.
and
Ranawat
,
A. S.
, “
Patellar Crepitus After Total Knee Revision
,”
Curr. Orthop. Pract.
, Vol.
21
, No.
5
,
2010
, pp.
538
540
. https://doi.org/10.1097/BCO.0b013e3181e7d4e0
7.
Buechel
,
F. F.
, “
Mobile-Bearing Knee Arthroplasty: Rotation Is Our Salvation!
J. Arthroplasty
, Vol.
19
, No. 1,
2004
, pp.
27
30
. https://doi.org/10.1016/j.arth.2004.02.011
8.
Pagnano
,
M. W.
,
Trousdale
,
R. T.
,
Stuart
,
M. J.
,
Hanssen
,
A. D.
, and
Jacofsky
,
D. J.
, “
Rotating Platform Knees Did not Improve Patellar Tracking: A Prospective, Randomized Study of 240 Primary Total Knee Arthroplasties
,”
Clin. Orthop. Relat. Res.
, Vol.
428
,
2004
, pp.
221
227
. https://doi.org/10.1097/01.blo.0000148892.31464.81
9.
Ranawat
,
A. D.
,
Ranawat
,
C. S.
,
Slamin
,
J. E.
, and
Dennis
,
D. A.
, “
Patellar Crepitation in the PFC Sigma Total Knee System
,”
Orthopedics
, Vol.
29
, No. 9,
2006
, pp.
68
70
.
10.
Meftah
,
M.
,
Ranawat
,
A. S.
, and
Ranawat
,
C. S.
The Natural History of Anterior Knee Pain in 2 Posterior-Stabilized, Modular Total Knee Arthroplasty Designs
,”
J. Arthroplasty
(in press).
11.
Breugem
,
S. J. M.
,
Sierevelt
,
I. N.
,
Schafroth
,
M. U.
,
Blankevoort
,
L.
, and
Schaap
,
G. R.
, “
Less Anterior Knee Pain with a Mobile-Bearing Prosthesis Compared with a Fixed-Bearing Prosthesis
,”
Clin. Orthop. Relat. Res.
, Vol.
466
,
2008
, pp.
1959
1965
. https://doi.org/10.1007/s11999-008-0320-6
12.
Pollock
,
D. C.
,
Ammeen
,
D. J.
, and
Engh
,
G. A.
Synovial entrapment: a complication of posterior stabilized total knee arthroplasty
,”
J. Bone Joint Surg.
, Vol.
84
(
A
),
2002
, pp.
2174
2178
.
13.
Maheshwari
,
A. V.
,
Blum
,
Y. C.
,
Shekhar
,
L.
,
Ranawat
,
A. S.
, and
Ranawat
,
C. S.
Multimodal Pain Management After Total Hip and Knee Arthroplasty at the Ranawat Orthopaedic Center
,”
Clin. Orthop. Relat. Res.
, Vol.
467
,
2009
, pp.
1418
1423
. https://doi.org/10.1007/s11999-009-0728-7
14.
Indelli
,
P. F.
,
Aglietti
,
P.
,
Buzzi
,
R.
, and
Baldini
,
A.
, “
The Insall-Burstein II Prosthesis: A 5- to 9-Year Follow-Up Study in Osteoarthritic Knees
J. Arthroplasty
, Vol.
17
, No. 5,
2002
, pp.
544
549
. https://doi.org/10.1054/arth.2002.32186
15.
Khaw
,
F. M.
,
Kirk
,
L. M.
, and
Gregg
,
P. J.
, “
Survival Analysis of Cemented Press-Fit Condylar Total Knee Arthroplasty
,”
J. Arthroplasty
, Vol.
16
, No.
2
,
2001
, pp.
161
167
. https://doi.org/10.1054/arth.2001.20254
16.
Colizza
,
W. A.
,
Insall
,
J. N.
, and
Scuderi
,
G. R.
, “
The Posterior Stabilized Total Knee Prosthesis: Assessment of Polyethylene Damage and Osteolysis After a Ten-Year-Minimum Follow-Up
,”
J. Bone Joint Surg.
, Vol.
77
(
A
),
1995
, pp.
1713
1720
.
17.
Francke
,
E. I.
and
Lachiewicz
,
P. F.
, “
Failure of a Cemented All-Polyethylene Patellar Component of a Press-Fit Condylar Total Knee Arthroplasty
,”
J. Arthroplasty
, Vol.
15
, No.
2
,
2000
, pp.
234
237
. https://doi.org/10.1016/S0883-5403(00)90396-6
18.
Parks
,
N. L
,
Engh
,
G. A
,
Topoleski
,
L. D
, and
Emperado
,
J.
, “
Modular Tibial Insert Micromotion: A Concern with Contemporary Knee Implants
,”
Clin. Orthop.
, Vol.
356
,
1998
, pp.
10
15
. https://doi.org/10.1097/00003086-199811000-00003
19.
Wasielewski
,
R. C.
,
Parks
,
N.
,
Williams
,
I.
,
Surprenant
,
H.
,
Collier
,
J. P.
, and
Engh
,
G.
, “
Tibial Insert Undersurface as a Contributing Source of Polyethylene Wear Debris
,”
Clin. Orthop.
, Vol.
345
,
1997
, pp.
53
59
.
20.
Anderson
,
M. J.
,
Becker
,
D. L.
, and
Kieckbusch
,
T.
, “
Patellofemoral Complications After Posterior-Stabilized Total Knee Arthroplasty: A Comparison of 2 Different Implant Designs
,”
J. Arthroplasty
, Vol.
17
,
2002
, pp.
422
426
. https://doi.org/10.1054/arth.2002.32173
21.
Ip
,
D.
,
Wu
,
W. C.
, and
Tsang
,
W. L.
, “
Early Results of Posterior-Stabilized NexGen Legacy Total Knee Arthroplasty
,”
J. Orthop. Surg. (Hong Kong)
Vol.
11
,
2003
, pp.
38
42
.
22.
Maloney
,
W. J.
,
Schmidt
,
R.
, and
Sculco
,
T. P.
, “
Femoral Component Design and Patellar Clunk Syndrome
,”
Clin. Orthop. Relat. Res.
, Vol.
410
,
2003
, pp.
199
202
. https://doi.org/10.1097/01.blo.0000063606.67412.96
23.
Rossi
,
R.
,
Ferro
,
A.
, and
Bruzzone
,
M.
, “
NexGen LPS Rotating Platform Total Knee Arthroplasty: Medium-Term Results of a Prospective Study
,”
Musculoskeletal Surg.
, Vol.
93
,
2009
, pp.
65
70
. https://doi.org/10.1007/s12306-009-0027-1
This content is only available via PDF.
You do not currently have access to this content.