Abstract

Standard Reference Material (SRM®) series 2951 to 2958 (5 μg to 1000 μg) Respirable Alpha Quartz on Filter and SRM series 2961 to 2967 (5 μg to 1000 μg) Respirable Cristobalite on Filter were prepared gravimetrically by depositing SRM 1878a Respirable Alpha Quartz and SRM 1879a Respirable Cristobalite on filters, respectively. These new SRMs are developed to assure the quality of respirable crystalline silica measurements using x-ray diffraction and infrared spectrometry around the regulatory limits that are enforced by the Occupational Safety and Health Administration (OSHA). The mass of silica determined by highly sensitive, but non-polymorph-specific, inductively coupled plasma optical emission spectrometry (ICP-OES) was successfully used to calculate the mass of polymorphspecific crystalline silica on filter after all sources of Si on the new SRMs were carefully analyzed. The certified values of alpha quartz in SRMs 2951 to 2958 and cristobalite in SRMs 2961 to 2967, respectively, were established from the gravimetric preparation values and the spectrometric measurement values.

References

1.
NIOSH Hazard Review: Health Effects of Occupational Exposure to Respirable Crystalline Silica
,”
DHHS (NIOSH) Publication
No. 2002-129,
04
2002
.
2.
NIOSH Manual of Analytical Methods (NMAM®)
,”
M. E.
Cassinelli
and
P. F.
O'Connor
, Eds.,
DHHS (NIOSH) Publication
 94-113, 4th ed.,
08
1994
.
3.
Yu
,
L. L.
,
Fassett
,
J. D.
, and
Lindstrom
A. P.
,
J. Anal. At. Spectrom.
 0267-9477,
18
,
2003
, p. 738.
4.
May
,
W.
,
Parris
,
R.
,
Beck
,
C.
,
Fassett
,
J.
,
Greenberg
,
R.
,
Guenther
,
F.
, et al
, “
Definitions of Terms and Modes Used at NIST for Value-Assignment of Reference Materials for Chemical Measurements
,”
NIST special publication
 260-136,
US Government Printing Office
,
Washington, DC, USA
,
2000
.
5.
Guide to the Expression of Uncertainty in Measurement
,” ISBN 92-67-10188-9, 1st ed.,
ISO
,
Geneva, Switzerland
,
1993
.
6.
Taylor
,
B. N.
and
Kuyatt
,
C. E.
, “
Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results
,”
NIST Technical Note
 1297,
US Government Printing Office
,
Washington
,
1994
.
7.
Miller
,
J. C.
and
Miller
,
J. N.
, “
Statistics for Analytical Chemistry
,”
Wiley
,
New York
,
1984
.
8.
Levenson
,
M. S.
,
Banks
,
D. L.
,
Eberhardt
,
K. R.
,
Gills
,
L. M.
,
Guthrie
,
W. F.
,
Liu
,
H. K.
, et al
,
J. Res. Natl. Inst. Stand. Technol.
 1044-677X,
105
,
2000
, p. 571.
This content is only available via PDF.