This paper presents performance definitions for calculating the overall effectiveness of three-fluid heat and moisture exchangers. The three-fluid heat and moisture exchanger considered in this paper is a combination of a liquid-to-liquid heat exchanger for heat transfer between a desiccant solution and a refrigerant and an energy exchanger for heat and moisture transfer between desiccant solution and air streams. The performance definitions presented in this paper are used to calculate the overall sensible and latent effectivenesses of a three-fluid heat and moisture exchanger, which has been tested under air cooling and dehumidifying operating conditions in a previous work (Abdel-Salam et al., 2016, “Design and Testing of a Novel 3-Fluid Liquid-to-Air Membrane Energy Exchanger (3-Fluid LAMEE),” Int. J. Heat Mass Transfer, 92, pp. 312–329). The effectiveness of this three-fluid heat and moisture exchanger is compared when calculated using the traditional energy exchanger effectiveness equations and the overall performance definitions. Results show that the overall performance definitions provide effectiveness values that are less sensitive to changes in the inlet refrigerant temperature and therefore are more generally applicable for energy exchanger design than the traditional effectiveness equations used in the literature.

References

1.
Abdel-Salam
,
M. R. H.
,
Fauchoux
,
M.
,
Ge
,
G.
,
Besant
,
R. W.
, and
Simonson
,
C. J.
,
2014
, “
Expected Energy and Economic Benefits, and Environmental Impacts for Liquid-to-Air Membrane Energy Exchangers (LAMEEs) in HVAC Systems: A Review
,”
Appl. Energy
,
127
, pp.
202
218
.
2.
Ge
,
G.
,
Abdel-Salam
,
M. R. H.
,
Besant
,
R. W.
, and
Simonson
,
C. J.
,
2013
, “
Research and Applications of Liquid-to-Air Membrane Energy Exchangers in Building HVAC Systems at University of Saskatchewan: A Review
,”
Renewable Sustainable Energy Rev.
,
26
, pp.
464
479
.
3.
Bergero
,
S.
, and
Chiari
,
A.
,
2011
, “
On the Performances of a Hybrid Air-Conditioning System in Different Climatic Conditions
,”
Energy
,
36
(
8
), pp.
5261
5273
.
4.
Abdel-Salam
,
A. H.
, and
Simonson
,
C. J.
,
2014
, “
Annual Evaluation of Energy, Environmental and Economic Performances of a Membrane Liquid Desiccant Air Conditioning System With/Without ERV
,”
Appl. Energy
,
116
, pp.
134
148
.
5.
Bergero
,
S.
, and
Chiari
,
A.
,
2001
, “
Experimental and Theoretical Analysis of Air Humidification/Dehumidification Processes Using Hydrophobic Capillary Contactors
,”
Appl. Therm. Eng.
,
21
(
11
), pp.
1119
1135
.
6.
Abdel-Salam
,
M. R. H.
,
Ge
,
G.
,
Fauchoux
,
M.
,
Besant
,
R. W.
, and
Simonson
,
C. J.
,
2014
, “
State-of-the-Art in Liquid-to-Air Membrane Energy Exchangers (LAMEEs): A Comprehensive Review
,”
Renewable Sustainable Energy Rev.
,
39
, pp.
700
728
.
7.
Abdel-Salam
,
M. R. H.
,
Besant
,
R. W.
, and
Simonson
,
C. J.
,
2015
, “
Sensitivity of the Performance of a Flat-Plate Liquid-to-Air Membrane Energy Exchanger (LAMEE) to the Air and Solution Channel Widths and Flow Maldistribution
,”
Int. J. Heat Mass Transfer
,
84
, pp.
1082
1100
.
8.
Huang
,
S. M.
, and
Zhang
,
L. Z.
,
2013
, “
Researches and Trends in Membrane-Based Liquid Desiccant Air Dehumidification
,”
Renewable Sustainable Energy Rev.
,
28
, pp.
425
440
.
9.
Abdel-Salam
,
M. R. H.
,
Besant
,
R. W.
, and
Simonson
,
C. J.
,
2016
, “
Design and Testing of a Novel 3-Fluid Liquid-to-Air Membrane Energy Exchanger (3-Fluid LAMEE)
,”
Int. J. Heat Mass Transfer
,
92
, pp.
312
329
.
10.
Abdel-Salam
,
M. R. H.
,
Besant
,
R. W.
, and
Simonson
,
C. J.
,
2016
, “
Performance Testing of a Novel 3-Fluid Liquid-to-Air Membrane Energy Exchanger (3-Fluid LAMEE) Under Desiccant Solution Regeneration Operating Conditions
,”
Int. J. Heat Mass Transfer
,
95
, pp.
773
786
.
11.
Shrivastava
,
D.
, and
Ameel
,
T. A.
,
2004
, “
Three-Fluid Heat Exchangers With Three Thermal Communications. Part B: Effectiveness Evaluation
,”
Int. J. Heat Mass Transfer
,
47
(17–18), pp.
3867
3875
.
12.
Abdel-Salam
,
M. R. H.
,
Besant
,
R. W.
, and
Simonson
,
C. J.
,
2016
, “
Experimental Study of Effects of Phase Change Energy and Operating Parameters on Performances of Two-Fluid and Three-Fluid Liquid-to-Air Membrane Energy Exchangers
,”
ASHRAE Trans.
,
122
(
1
), pp.
134
145
.
13.
Abdel-Salam
,
M. R. H.
,
Besant
,
R. W.
, and
Simonson
,
C. J.
,
2016
, “
Performance Testing of 2-Fluid and 3-Fluid Liquid-to-Air Membrane Energy Exchangers for HVAC Applications in Cold–Dry Climates
,”
Int. J. Heat Mass Transfer
(in press).
14.
Vali
,
A.
,
2009
, “
Modeling a Run-Around Heat and Moisture Exchanger Using Two Counter/Cross Flow Exchangers
,”
M.Sc. thesis
, Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, SK, Canada.
15.
eFunda
,
2016
, “
Thermal Conductivity: Titanium
,” eFunda, Sunnyvale, CA, accessed June 8, 2014, http://www.efunda.com/materials/elements/TC_Table.cfm?Element_ID=Ti
16.
Hemingson
,
H. B.
,
Simonson
,
C. J.
, and
Besant
,
R. W.
,
2011
, “
Steady-State Performance of a Run-Around Membrane Energy Exchanger (RAMEE) for a Range of Outdoor Air Conditions
,”
Int. J. Heat Mass Transfer
,
54
(9–10), pp.
1814
1824
.
You do not currently have access to this content.