Effects that two different compound-angle film-hole configurations have on film cooling effectiveness are investigated. Effectiveness measurements have been made downstream of a single row of compound-angle cylindrical holes with a diameter of 7.5 mm, and a single row of compound-angle, diffuser-shaped holes with an inlet diameter of 7.5 mm. Both geometries were inclined with respect to the coverage surface at an angle α of 25 deg. The cylindrical holes, however, were oriented perpendicular to the high-temperature airflow direction while the diffuser-shaped holes had a compound angle of 45 deg with respect to the high temperature air flow direction. Both geometries were tested over a blowing ratio range of 0.7 to 4.0 Surface temperatures were measured along four longitudinal rows of thermocouples covering the downstream area between two adjacent holes. The results showed that the best overall protection over the widest range of blowing ratios was provided by the diffuser-shaped film cooling holes, particularly at high blowing ratios. The increased cross-sectional area at the shaped hole exit lead to a reduction of the momentum flux of the jet exiting the hole. Therefore, the penetration of the jet into the main flow was reduced, resulting in an increased cooling effectiveness. CFD analyses were also performed to study the film cooling effectiveness downstream of the row of holes. Comparisons between the test and numerical results showed a reasonable agreement between the two, thus CFD can be considered a viable tool to predict the cooling performance of different film cooling configurations in a parametric study.
Skip Nav Destination
Article navigation
Technical Notes
Film Effectiveness Downstream of a Row of Compound Angle Film Holes
M. E. Taslim and,
M. E. Taslim and
Mechanical and Industrial Engineering Department, Northeastern University, Boston, MA 02115
Search for other works by this author on:
A. Khanicheh
A. Khanicheh
Mechanical and Industrial Engineering Department, Northeastern University, Boston, MA 02115
Search for other works by this author on:
M. E. Taslim and
Mechanical and Industrial Engineering Department, Northeastern University, Boston, MA 02115
A. Khanicheh
Mechanical and Industrial Engineering Department, Northeastern University, Boston, MA 02115
Contributed by the Heat Transfer Division for publication in the JOURNAL OF HEAT TRANSFER. Manuscript received by the Heat Transfer Division February 10, 2004; revision received December 15, 2004. Associate Editor: P. M. Ligrani.
J. Heat Transfer. Apr 2005, 127(4): 434-440 (7 pages)
Published Online: March 30, 2005
Article history
Received:
February 10, 2004
Revised:
December 15, 2004
Online:
March 30, 2005
Citation
Taslim and , M. E., and Khanicheh , A. (March 30, 2005). "Film Effectiveness Downstream of a Row of Compound Angle Film Holes ." ASME. J. Heat Transfer. April 2005; 127(4): 434–440. https://doi.org/10.1115/1.1865222
Download citation file:
Get Email Alerts
Cited By
Related Articles
Film Cooling Measurements for Cratered Cylindrical Inclined Holes
J. Turbomach (January,2009)
Measurement and Modeling of Confined Jet Discharged Tangentially on a Concave Semicylindrical Hot Surface
J. Heat Transfer (December,2011)
Effect of Pulsed Film Cooling on Leading Edge Film Effectiveness
J. Turbomach (July,2012)
Effect of Jet Pulsation and Duty Cycle on Film Cooling From a Single Jet on a Leading Edge Model
J. Turbomach (July,2006)
Related Proceedings Papers
Related Chapters
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Thermocouples: The Simplest Way to Measure Temperature Wrong
Hot Air Rises and Heat Sinks: Everything You Know about Cooling Electronics Is Wrong
Numerical Simulation Research on a Fixed Bed Gasifier
International Conference on Information Technology and Management Engineering (ITME 2011)