The relationship between the mean radial electrohydrodynamic (EHD) pressure and the rate of the axial momentum flux and its influence on heat transfer enhancement and pressure drop in EHD-enhanced convective boiling of R-134a in a horizontal smooth tube was investigated in detail. A simple theory, which included the characteristics of two-phase flow, was developed to determine the mean radial EHD pressure. It was shown that the amount of heat transfer enhancement and the pressure drop penalty were dependent upon the size of the mean radial EHD pressure relative to the rate of the axial momentum flux. The influence of the mass flux, change in quality, and saturation temperature on the mean radial EHD pressure relative to the rate of the axial momentum flux was also studied. This study has provided a greater understanding of EHD enhancement of the convective boiling heat transfer. [S0022-1481(00)01802-8]

1.
Eckels
,
S. J.
,
Doerr
,
T. M.
, and
Pate
,
M. B.
,
1994
, “
In-tube Heat Transfer and Pressure Drop of R-134a and Ester Lubricant Mixtures In a Smooth Tube and a Micro-fin Tube: Part I—Evaporation
,”
ASHRAE Transactions
,
100
, No.
2
, pp.
265
282
.
2.
Yabe
,
A.
,
Taketani
,
T.
,
Maki
,
H.
,
Takahshi
,
K.
, and
Nakadai
,
Y.
,
1992
, “
Experimental Study of Electrohydrodynamically Enhanced Evaporator for Nonazeotropic Mixtures
,”
ASHRAE Transactions
,
98
, No.
2
, pp.
455
461
.
3.
Singh, A., 1995, “Electrohydrodynamic (EHD) Enhancement of In-Tube Boiling and Condensation of Alternative (NON-CFC) Refrigerants,” Ph.D. dissertation, University of Maryland, College Park, MD.
4.
Salehi, M., Ohadi, M. M., and Dessiatoun, S., 1996, “Minimization of Pressure Drop for EHD-Enhanced In-tube Boiling of R-134a,” Advances in Energy Efficiency, Heat/Mass Transfer Enhancement, ASME, New York, pp. 25–31.
5.
Bryan, J. E., and Seyed-Yagoobi, J., 1997, “Influence of Flow Regime, Heat Flux, and Mass Flux on Electrohydrodynamically Enhanced Convective Boiling,” Proceedings of the ASME Heat Transfer Division, ASME, New York, pp. 187–196.
6.
Melcher, J. R., 1981, Continuum Electromechanics, MIT Press, Cambridge, MA.
7.
Bryan, J. E., 1998, “Fundamental Study of Electrohydrodynamically Enhanced Convective and Nucleate Boiling Heat Transfer,” Ph.D. dissertation, Texas A&M University, College Station, TX.
8.
Jones
,
T. B.
,
1977
, “
Bubble Dielectrophoresis
,”
J. Appl. Phys.
,
48
, No.
4
, pp.
1412
1417
.
9.
Taylor, J. R., 1982, An Introduction to Error Analysis, University Science Books, Mill Valley, CA.
10.
Kline
,
S. J.
, and
McClintock
,
F. A.
,
1953
, “
Describing Uncertainties in Single Sample Experiments
,”
Mech. Eng. (Am. Soc. Mech. Eng.)
,
75
, pp.
3
8
.
11.
Wattelet
,
J. P.
,
Chato
,
J. C.
,
Souza
,
A. L.
, and
Christoffersen
,
B. R.
,
1994
, “
Evaporative Characteristics of R-12, R-134a, and a Mixture at Low Mass Fluxes
,”
ASHRAE Transactions
, ,
100
, No.
1
, pp.
603
615
.
12.
Kandlikar
,
S. G.
,
1990
, “
A General Correlation for Saturated Two-Phase Flow Boiling Heat Transfer Inside Horizontal and Vertical Tubes
,”
ASME J. Heat Transfer
,
112
, pp.
219
228
.
13.
Torikoshi
,
K.
, and
Ebisu
,
T.
,
1993
, “
Heat Transfer and Pressure Drop Characteristics of R-134a, R-32, and a Mixture of R-32/R-134a Inside a Horizontal Tube
,”
ASHRAE Transactions
, ,
99
, No.
2
, pp.
90
96
.
14.
Carey, V. P., 1992, Liquid-Vapor Phase-Change Phenomena, Hemisphere, Washington, DC.
15.
Friedel, L., 1979, “Improved Friction Pressure Drop Correlations for Horizontal and Vertical Two-Phase Pipe Flow,” presented at The European Two-phase Flow Group, Meeting, Ispra, Italy, Paper E2.
16.
Collier, J. G., and Thome, J. R., 1994, Convective Boiling and Condensation, 3rd Ed. Clarendon Press, Oxford, UK.
17.
Thome
,
J. R.
,
1964
, “
Prediction of Pressure Drop During Forced Circulation Boiling of Water
,”
Int. J. Heat Mass Transf.
,
7
, pp.
709
724
.
18.
Crowley, J. M., 1986, Fundamentals of Applied Electrostatics, John Wiley and Sons, New York.
19.
Taitel
,
Y.
, and
Dukler
,
A. E.
,
1976
, “
A Model for Predicting Flow Regime Transitions in Horizontal and Near Horizontal Gas-liquid Flow
,”
AIChE J.
,
22
, pp.
47
55
.
20.
Tanaka
,
Y.
,
Tsujimoto
,
T.
,
Matsuo
,
S.
, and
Makita
,
T.
,
1992
, “
Dielectic Constant of Environmentally Accepted Refrigerants HFC-134a, HCFC-123, and HCFC-141b Under High Pressures
,”
Fluid Phase Equilibria
,
80
, pp.
107
117
.
21.
Bara˜o
,
M. T.
,
Mardolcar
,
U. V.
, and
Nieto de Castro
,
C. A.
,
1996
, “
The Dielectric Constant of Liquid HFC 134a and HCFC 142b
,”
Int. J. Thermophys.
,
17
, No.
3
, pp.
573
585
.
You do not currently have access to this content.