Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
NARROW
Format
Article Type
Subject Area
Date
Availability
1-17 of 17
Keywords: penetration tests
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Journal Articles
Journal:
Geotechnical Testing Journal
Publisher: ASTM International
Article Type: Technical Notes
Geotech. Test. J.. September 1997, 20(3): 357–361.
Paper No: GTJ19970011
Published Online: July 16, 2014
... dilatometer geophysics penetration tests shear wave velocity shear modulus shear wave small-strain modulus stiffness References Campanella , R. G. , “ Field Methods for Dynamic Geotechnical Testing: An Overview of Capabilities and Needs ,” Dynamic Geotechnical Testing 11, ASTM STP 1213...
Journal Articles
Journal:
Geotechnical Testing Journal
Publisher: ASTM International
Article Type: Research-Article
Geotech. Test. J.. December 1993, 16(4): 458–468.
Published Online: December 1, 1993
... functions are given for repeatability of the SPT, the CPTu, and an estimation of equivalent SPT values from the CPTu. KEYWORDS: cone penetrometer, penetration tests, correlation techniques Nomenclature CDF E F Cumulative distribution function Measurement uncertainty Algorithm bias indicator Stress...
Journal Articles
Journal:
Geotechnical Testing Journal
Publisher: ASTM International
Article Type: Research-Article
Geotech. Test. J.. March 1993, 16(1): 54–60.
Published Online: March 1, 1993
... a wide range in plasticity, sensitivity, stress history, and consistency. cone penetrometer clays cohesive soils correlation technique elasticity modulus field data field investigations geophysics penetration resistance penetration tests piezocones seismic waves shear wave wave velocity...
Journal Articles
Journal:
Geotechnical Testing Journal
Publisher: ASTM International
Article Type: Technical Notes
Geotech. Test. J.. June 1990, 13(2): 129–133.
Published Online: June 1, 1990
...). The parametric study involves field set-up conditions, number of instruments per side, and the size of the grid used in the reconstruction. References Campanella , R. G. , Robertson , P. K. , and Gillespie , D. , “ Seismic Cone Penetration Test ,” Use of In Situ Tests in Geotechnical...
Journal Articles
Journal:
Geotechnical Testing Journal
Publisher: ASTM International
Article Type: Research-Article
Geotech. Test. J.. December 1988, 11(4): 257–262.
Published Online: December 1, 1988
... in the literature. soil investigations penetration tests sands modulus of deformation repeated loading relative density References Schwarz , S. D. and Musser , J. M. , “ Various Techniques for Making In-Situ Shear Wave Measurements ,” Proceedings of the International Conference...
Journal Articles
Journal:
Geotechnical Testing Journal
Publisher: ASTM International
Article Type: Research-Article
Geotech. Test. J.. September 1988, 11(3): 179–186.
Published Online: September 1, 1988
...FY Yokel; PW Mayne Helical test probes of different sizes suitable for shallow (1.8-m) in-situ soil exploration and compaction control were developed and tested in different soils alongside traditional in-situ tests, including Standard Penetration tests (SPT), cone penetration tests (CPT...
Journal Articles
Journal:
Geotechnical Testing Journal
Publisher: ASTM International
Article Type: Research-Article
Geotech. Test. J.. June 1988, 11(2): 139–147.
Published Online: June 1, 1988
...PW Mayne; JB Kemper, Jr Standard penetration tests (SPT) and cone penetration tests (CPT) have conventionally been used to index profiles of undrained shear strength s u in clay deposits. Since s u is related to stress history, an alternative use of penetration resistances is the profiling...
Journal Articles
Journal:
Geotechnical Testing Journal
Publisher: ASTM International
Article Type: Research-Article
Geotech. Test. J.. June 1986, 9(2): 93–101.
Published Online: June 1, 1986
... for improving the accuracy, usefulness, or acceptability of the proposed method. penetration tests dilatometer tests pressures stress soil deformation References Jamiolkowski , B. M. , Ladd , C. C. , Jermaine , J. T. , and Lancelotta , R. , “ New Developments in Field...
Journal Articles
Journal:
Geotechnical Testing Journal
Publisher: ASTM International
Article Type: Research-Article
Geotech. Test. J.. September 1984, 7(3): 158–163.
Published Online: September 1, 1984
...CO Riggs; GM Mathes; CL Rassieur A field comparison is made of standard penetration test (SPT) N values obtained using three automatic free fall hammers of the same design with N values obtained by five cathead and rope operators using four different drill rigs. A comparison of mean N values using...
Journal Articles
Journal:
Geotechnical Testing Journal
Publisher: ASTM International
Article Type: Research-Article
Geotech. Test. J.. December 1983, 6(4): 201–209.
Published Online: December 1, 1983
...CO Riggs; NO Schmidt; CL Rassieur Stress wave energy measurements were made to compare the performance of an automatic standard penetration test (SPT) hammer system with the free fall performance of a safety type hammer. It was found that the automatic free fall hammer and the safety hammer tested...
Journal Articles
Journal:
Geotechnical Testing Journal
Publisher: ASTM International
Article Type: Research-Article
Geotech. Test. J.. September 1982, 5(3/4): 89–92.
Published Online: September 1, 1982
...CO Riggs A standard test method for a free fall penetration test is proposed. Rigid constraints on both mass and geometry of the drive weight and the anvil should provide a reliably reproducible force at impact and a reliably reproducible energy within equivalent sampling rod-sampler configurations...
Journal Articles
Journal:
Geotechnical Testing Journal
Publisher: ASTM International
Article Type: Technical Notes
Geotech. Test. J.. March 1982, 5(1/2): 42–46.
Published Online: March 1, 1982
... vary with the internal friction angle of the soil. A series of static penetration tests in dry sand show the variation of the ratio of shear and normal forces on the probe face ( R/N ) with soil friction angle φ. soil tests sands soil mechanics foundation investigations penetration tests...
Journal Articles
Journal:
Geotechnical Testing Journal
Publisher: ASTM International
Article Type: Technical Notes
Geotech. Test. J.. September 1981, 4(3): 126–129.
Published Online: September 1, 1981
...WD Kovacs Geotechnical engineers in the United States commonly use the results of the ASTM Penetration Test and Split-Barrel Sampling of Soils (D 1586) in subsurface investigations for routine foundation design. Wide variations occur in standard penetration test (SPT) results because the present...
Journal Articles
Journal:
Geotechnical Testing Journal
Publisher: ASTM International
Article Type: Technical Notes
Geotech. Test. J.. December 1980, 3(4): 163–166.
Published Online: December 1, 1980
..., penetration, and energy values were determined from the measured penetration into a standard material (Oasis floral foam). The data obtained indicate that rod length is a significant factor with respect to penetration and energy delivered. penetration tests energy shear strength rod impact blow count...
Journal Articles
Journal:
Geotechnical Testing Journal
Publisher: ASTM International
Article Type: Technical Notes
Geotech. Test. J.. September 1980, 3(3): 127–130.
Published Online: September 1, 1980
...WD Kovacs There are wide variations in physical configuration and cathead equipment among the available drill rigs used to perform the standard penetration test. Such differences may be partly responsible for variations in blow count among different drill rigs. The paper draws attention to the fact...
Journal Articles
Journal:
Geotechnical Testing Journal
Publisher: ASTM International
Article Type: Research-Article
Geotech. Test. J.. September 1979, 2(3): 136–142.
Published Online: September 1, 1979
.... Two frozen undisturbed samples were cut from the walls of the shaft in loose gravel layer and the in-situ density was determined using a fluid displacement technique. Maximum and minimum densities were obtained for the thawed soil for calculation of in-situ relative density. Standard Penetration Test...
Journal Articles
Journal:
Geotechnical Testing Journal
Publisher: ASTM International
Article Type: Research-Article
Geotech. Test. J.. June 1978, 1(2): 72–81.
Published Online: June 1, 1978
...WD Kovacs; AH Griffith; JC Evans Previous studies by the authors have found that a cathead and rope when used to perform standard penetration tests (SPT) have resulted in energies reaching the striker plate or anvil substantially less than those resulting from a complete or 100% free fall. In fact...